Selecting the Best Ventilator Hyperinflation Settings (VHI1)
Selecting the Best Ventilator Hyperinflation Settings Based on Physiologic Markers: Randomized Controlled Study
Przegląd badań
Status
Interwencja / Leczenie
Szczegółowy opis
Background: Ventilator Hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, there are no recommendations on the best ventilator settings to perform the technique. Thus, the aim of this study was to compare six modes of VHI, concerning physiological markers of efficacy and safety criteria, in order to support the optimal VHI settings selection for mechanically ventilated patients.
Methods: In a crossover study, every included mechanically ventilated patient underwent six modes of VHI in a randomized order: Volume Control Continuous Mandatory Ventilation (VC-CMV) with inspiratory flow = 20Lpm (VC-CMV20), VC-CMV with inspiratory flow = 50Lpm (VC-CMV50), Pressure Control Continuous Mandatory Ventilation (PC-CMV) with inspiratory time = 1s. (PC-CMV1), PC-CMV with inspiratory time = 3s. (PC-CMV3), Pressure Support Ventilation (PSV) with cycling off = 10% of peak inspiratory flow (PSV10), and PSV with cycling off = 25% of peak inspiratory flow (PSV25). The maximum expansion (tidal volume), expiratory flow bias criteria (inspiratory and expiratory flow patterns), over-distension (alveolar pressure), asynchronies and hemodynamic variables (mean arterial pressure and heart rate) were assessed during the interventions.
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Patients under mechanical ventilation for more than 48h
Exclusion Criteria:
- mucus hypersecretion (defined as the need for suctioning < 2-h intervals),
- absence of respiratory drive,
- atelectasis,
- severe bronchospasm,
- positive end expiratory pressure > 10cmH2O,
- PaO2-FiO2 relationship < 150,
- mean arterial pressure < 60mmHg,
- inotrope requirement equivalent to >15 ml/h total of adrenaline and noradrenalin,
- intracranial pressure > 20mmHg
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Zadanie krzyżowe
- Maskowanie: Pojedynczy
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
---|---|
Brak interwencji: BASELINE
The subjects were kept in their current ventilatory mode.
|
|
Eksperymentalny: VC-CMV20
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) with an inspiratory flow of 20Lpm.
|
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV).
The inspiratory flow was set at 20Lpm and the tidal volume was increased in steps of 200mL until the peak airway pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
Eksperymentalny: VC-CMV50
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) with an inspiratory flow of 50Lpm.
|
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV).
The inspiratory flow was set at 50Lpm and the tidal volume was increased in steps of 200mL until the peak airway pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
Eksperymentalny: PC-CMV1
Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1) with an inspiratory time of 1 second.
|
Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1).
The inspiratory time was set at 1 second and the pressure control was increased until a peak pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
Eksperymentalny: PC-CMV3
Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1) with an inspiratory time of 3 seconds.
|
Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1).
The inspiratory time was set at 3 seconds and the pressure control was increased until a peak pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
Eksperymentalny: PSV10
Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV) with a cycling off of 10% of peak inspiratory flow.
|
Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV).
The cycling off was set at 10% of peak inspiratory flow and the pressure support was increased until a peak pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
Eksperymentalny: PSV25
Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV) with a cycling off of 25% of peak inspiratory flow.
|
Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV).
The cycling off was set at 25% of peak inspiratory flow and the pressure support was increased until a peak pressure of 40cmH2O was achieved.
After achieving the target pressure, this ventilatory regimen lasted 15 minutes.
Positive end expiratory pressure and the inspired oxygen fraction were not modified.
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
---|---|---|
Peak inspiratory to expiratory flow ratio
Ramy czasowe: Ten minutes after the onset of intervention.
|
Dichotomous variable, defined as achieving a peak inspiratory flow rate (PIFR) less than 90% of the peak expiratory flow rate (PEFR)
|
Ten minutes after the onset of intervention.
|
Peak expiratory flow higher than 40 Lpm
Ramy czasowe: Ten minutes after the onset of intervention.
|
Dichotomous variable, defined as achieving a PEFR higher than 40 l/min
|
Ten minutes after the onset of intervention.
|
Difference between peak inspiratory and expiratory flows.
Ramy czasowe: Ten minutes after the onset of intervention.
|
Dichotomous variable, defined as achieving a difference higher than 17Lpm.
|
Ten minutes after the onset of intervention.
|
Pulmonary expansion
Ramy czasowe: Ten minutes after the onset of intervention.
|
Percentage of tidal volume above the normal tidal volume (estimated as 6mL/kg).
|
Ten minutes after the onset of intervention.
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
---|---|---|
Mean arterial pressure
Ramy czasowe: Ten minutes after the onset of intervention.
|
Mean arterial pressure verified using the multi-parameter monitor.
|
Ten minutes after the onset of intervention.
|
Heart Rate
Ramy czasowe: Ten minutes after the onset of intervention.
|
Heart rate verified using the multi-parameter monitor.
|
Ten minutes after the onset of intervention.
|
Współpracownicy i badacze
Współpracownicy
Śledczy
- Krzesło do nauki: FERNANDO S GUIMARAES, PhD, Centro Universitário Augusto Motta
Publikacje i pomocne linki
Publikacje ogólne
- Berney S, Denehy L. A comparison of the effects of manual and ventilator hyperinflation on static lung compliance and sputum production in intubated and ventilated intensive care patients. Physiother Res Int. 2002;7(2):100-8. doi: 10.1002/pri.246.
- Lemes DA, Zin WA, Guimaraes FS. Hyperinflation using pressure support ventilation improves secretion clearance and respiratory mechanics in ventilated patients with pulmonary infection: a randomised crossover trial. Aust J Physiother. 2009;55(4):249-54. doi: 10.1016/s0004-9514(09)70004-2.
- Thomas PJ. The effect of mechanical ventilator settings during ventilator hyperinflation techniques: a bench-top analysis. Anaesth Intensive Care. 2015 Jan;43(1):81-7. doi: 10.1177/0310057X1504300112.
- Ntoumenopoulos G, Shannon H, Main E. Do commonly used ventilator settings for mechanically ventilated adults have the potential to embed secretions or promote clearance? Respir Care. 2011 Dec;56(12):1887-92. doi: 10.4187/respcare.01229. Epub 2011 Jun 17.
- Anderson A, Alexanders J, Sinani C, Hayes S, Fogarty M. Effects of ventilator vs manual hyperinflation in adults receiving mechanical ventilation: a systematic review of randomised clinical trials. Physiotherapy. 2015 Jun;101(2):103-10. doi: 10.1016/j.physio.2014.07.006. Epub 2014 Oct 6.
- Davies JD, Senussi MH, Mireles-Cabodevila E. Should A Tidal Volume of 6 mL/kg Be Used in All Patients? Respir Care. 2016 Jun;61(6):774-90. doi: 10.4187/respcare.04651.
- de Wit M. Monitoring of patient-ventilator interaction at the bedside. Respir Care. 2011 Jan;56(1):61-72. doi: 10.4187/respcare.01077.
Przydatne linki
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- VHI1
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na VC-CMV20
-
ViaCyteCalifornia Institute for Regenerative Medicine (CIRM)ZakończonyCukrzyca typu 1Kanada, Stany Zjednoczone
-
National Defense Medical Center, TaiwanZakończonyBól, ostry | Zachowanie niemowlęcia | Stres fizjologiczny | Mleko matkiTajwan
-
ViaCyteZakończonyCukrzyca typu 1Stany Zjednoczone
-
Queen's University, BelfastAWARE NI; Northern Ireland Public Health Research NetworkZakończonyDepresjaZjednoczone Królestwo
-
ViaCyteZakończonyCukrzyca typu 1Kanada
-
VA Office of Research and DevelopmentJeszcze nie rekrutacjaPrzewlekła obturacyjna choroba płucStany Zjednoczone
-
Sunnybrook Health Sciences CentreCanadian Initiative for Outcomes in Rheumatology CareZakończony
-
ViaCyteCalifornia Institute for Regenerative Medicine (CIRM); Horizon 2020 - European...ZakończonyCukrzyca typu 1 z hipoglikemiąStany Zjednoczone, Kanada, Belgia
-
University Medical Center GroningenZakończony
-
International Centre for Diarrhoeal Disease Research...RekrutacyjnyPróba nieniższościBangladesz