Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography
Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography in Patients With Auditory Hallucinations and Healthy Controls
Aperçu de l'étude
Statut
Statut
Les conditions
Les conditions
Intervention / Traitement
Intervention / Traitement
Type d'étude
Type d'étude
Inscription (Réel)
Inscription
Phase
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Fuyang, Chine
- Fuyang Mental Heath Center
-
-
Critères de participation
Critère d'éligibilité
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
- Age 18 to 65 years;
- Meet the diagnostic criteria for schizophrenia according to the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5);
- Adequate verbal communication skills;
- At least one auditory hallucination episode within the past week;
- Willing to participate in the study and able to complete all trial procedures.
Exclusion Criteria:
- History of neurological disorders, severe physical illness, traumatic brain injury, or craniotomy;
- History of epileptic seizures or other neuropsychiatric disorders;
- At risk for suicide, self-injury, or impulsive behavior.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation croisée
- Masquage: Double
Nombre de bras
Armes et Interventions
Groupe de participants / BrasGroupe de participants / Bras |
Intervention / TraitementIntervention / Traitement |
|---|---|
|
Expérimental: 0.4mA-10Hz HD-tACS
For 0.4mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: 0.4mA-20Hz HD-tACS
For 0.4mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: 0.4mA-40Hz HD-tACS
For 0.4mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: 0.4mA-140Hz HD-tACS
For 0.4mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: 1mA-10Hz HD-tACS
For 1mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: 1mA-20Hz HD-tACS
For 1mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: 1mA-40Hz HD-tACS
For 1mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: 1mA-140Hz HD-tACS
For 1mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: 2mA-10Hz HD-tACS
For 2mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: 2mA-20Hz HD-tACS
For 2mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: 2mA-40Hz HD-tACS
For 2mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: 2mA-140Hz HD-tACS
For 2mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Expérimental: sham HD-tACS
For sham HD-tACS, we will stimulate the personalized left or right temporal lobe channel using sham HD-tACS pattern.
|
The sham intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
To mimic the sensory experience of active stimulation, the sham condition includes a 10-second ramp-up and a 5-second ramp-down period at 0.4 mA and 140 Hz, with no current delivered during the intervening 90-second period.
|
Que mesure l'étude ?
Principaux critères de jugement
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Beta2-band EEG power at the stimulation site
Délai: 180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in beta2 band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
Mesures de résultats secondaires
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Alpha-band EEG power at the stimulation site
Délai: 180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in alpha band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Delta-band EEG power at the stimulation site
Délai: 180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in delta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Theta-band EEG power at the stimulation site
Délai: 180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in theta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Gamma-band EEG power at the stimulation site
Délai: 180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in gamma band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Beta2-band functional connectivity measured by EEG wPLI
Délai: 180-second recording after each 90-second stimulation
|
Beta2-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Alpha-band functional connectivity measured by EEG wPLI
Délai: 180-second recording after each 90-second stimulation
|
Alpha-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Delta-band functional connectivity measured by EEG wPLI
Délai: 180-second recording after each 90-second stimulation
|
Delta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Theta-band functional connectivity measured by EEG wPLI
Délai: 180-second recording after each 90-second stimulation
|
Theta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Gamma-band functional connectivity measured by EEG wPLI
Délai: 180-second recording after each 90-second stimulation
|
Gamma-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
Collaborateurs et enquêteurs
Parrainer
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Début de l'étude
Achèvement primaire (Réel)
Achèvement primaire
Achèvement de l'étude (Réel)
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Première publication
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour publiée
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Dernière vérification
Plus d'information
Termes liés à cette étude
Autres numéros d'identification d'étude
Autres numéros d'identification d'étude
- HFJiang-006
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .