Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography
Frequency- and Intensity-Dependent After-Effects of High-Definition Transcranial Alternating Current Stimulation on Resting-State Electroencephalography in Patients With Auditory Hallucinations and Healthy Controls
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Phase
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Fuyang, China
- Fuyang Mental Heath Center
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Beschreibung
Inclusion Criteria:
- Age 18 to 65 years;
- Meet the diagnostic criteria for schizophrenia according to the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5);
- Adequate verbal communication skills;
- At least one auditory hallucination episode within the past week;
- Willing to participate in the study and able to complete all trial procedures.
Exclusion Criteria:
- History of neurological disorders, severe physical illness, traumatic brain injury, or craniotomy;
- History of epileptic seizures or other neuropsychiatric disorders;
- At risk for suicide, self-injury, or impulsive behavior.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Crossover-Aufgabe
- Maskierung: Doppelt
Anzahl der Arme
Waffen und Interventionen
Teilnehmergruppe / ArmTeilnehmergruppe / Arm |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Experimental: 0.4mA-10Hz HD-tACS
For 0.4mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: 0.4mA-20Hz HD-tACS
For 0.4mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: 0.4mA-40Hz HD-tACS
For 0.4mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 20 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: 0.4mA-140Hz HD-tACS
For 0.4mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: 1mA-10Hz HD-tACS
For 1mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: 1mA-20Hz HD-tACS
For 1mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: 1mA-40Hz HD-tACS
For 1mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: 1mA-140Hz HD-tACS
For 1mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: 2mA-10Hz HD-tACS
For 2mA-10Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: 2mA-20Hz HD-tACS
For 2mA-20Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: 2mA-40Hz HD-tACS
For 2mA-40Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: 2mA-140Hz HD-tACS
For 2mA-140Hz HD-tACS prevention, we will stimulate the personalized left or right temporal lobe channel at 10 Hz and 0.4mA.
|
The active intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
Stimulation is administered for 90 seconds per condition, with the frequency and current intensity set according to the experimental protocol.
A 10-second ramp-up and a 5-second ramp-down period are included in each stimulation condition.
The stimulus waveform is sinusoidal.
Stimulation is delivered using saline-soaked sponge electrodes.
Electrode impedance is maintained below 10 kΩ throughout the stimulation session.
|
|
Experimental: sham HD-tACS
For sham HD-tACS, we will stimulate the personalized left or right temporal lobe channel using sham HD-tACS pattern.
|
The sham intervention consists of high-definition transcranial alternating current stimulation (HD-tACS) delivered using a 4×1 ring configuration (one center electrode surrounded by four return electrodes) over the personalized left or right temporal lobe.
The return electrodes deliver one-quarter of the central electrode current with opposite polarity.
To mimic the sensory experience of active stimulation, the sham condition includes a 10-second ramp-up and a 5-second ramp-down period at 0.4 mA and 140 Hz, with no current delivered during the intervening 90-second period.
|
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Beta2-band EEG power at the stimulation site
Zeitfenster: 180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in beta2 band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Alpha-band EEG power at the stimulation site
Zeitfenster: 180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in alpha band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Delta-band EEG power at the stimulation site
Zeitfenster: 180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in delta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Theta-band EEG power at the stimulation site
Zeitfenster: 180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in theta band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Gamma-band EEG power at the stimulation site
Zeitfenster: 180-second recording after each 90-second stimulation
|
Changes in EEG power(dB) in gamma band within different frequency band measured at the temporal lobe during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Beta2-band functional connectivity measured by EEG wPLI
Zeitfenster: 180-second recording after each 90-second stimulation
|
Beta2-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Alpha-band functional connectivity measured by EEG wPLI
Zeitfenster: 180-second recording after each 90-second stimulation
|
Alpha-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Delta-band functional connectivity measured by EEG wPLI
Zeitfenster: 180-second recording after each 90-second stimulation
|
Delta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Theta-band functional connectivity measured by EEG wPLI
Zeitfenster: 180-second recording after each 90-second stimulation
|
Theta-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
|
Gamma-band functional connectivity measured by EEG wPLI
Zeitfenster: 180-second recording after each 90-second stimulation
|
Gamma-band functional connectivity between predefined EEG electrodes, quantified using the weighted Phase Lag Index (wPLI), during the 180-second resting-state EEG recording immediately following each stimulation condition.
|
180-second recording after each 90-second stimulation
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- HFJiang-006
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Beschreibung des IPD-Plans
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .