Clinical Evaluation of SHOFU FX-LC RMGI Restoration Versus FUJI II RGMI in Management of Anterior Carious Cervical Lesions
Clinical Evaluation of Acrylamide Based RMGI Restoration Versus Conventional Resin Modified Glass Ionomer in Management of Patients Having Anterior Carious Cervical Lesions: A Randomized Clinical Trial.
The development of resin-modified glass ionomers (RMGIs) represents a strategic evolution designed to augment the mechanical performance of conventional glass ionomers. By incorporating a resin matrix, these materials achieve notable physical improvements, including superior fracture toughness, increased resistance to occlusal wear, and higher resilience to moisture degradation, alongside the clinical advantage of a prolonged working time. (Hübel 2003)However, an excessive proportion of hydrophobic multifunctional monomers within the RMGI matrix suppresses the essential aqueous acid-base reaction.
To overcome conventional resin modified glass ionomer drawbacks, FX-LC tried to overcome it by incorporating a new multifunctional acrylamide monomer called New Generation Acrylamide monomer (NGA monomer) with which they claim that it exhibits high water solubility due to its four amide bonds (-CO-NH-) and demonstrates high polymerization reactivity, even in the presence of water. It has unique properties that are not found in conventional multifunctional monomers
Aperçu de l'étude
Statut
Statut
Les conditions
Les conditions
Intervention / Traitement
Intervention / Traitement
Type d'étude
Type d'étude
Inscription (Estimé)
Inscription
Phase
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
Coordonnées de l'étude
- Nom: Salma hany Nadeem, BDS 2022
- Numéro de téléphone: (+2)01033719904
- E-mail: salma.hany@dentistry.cu.edu.eg
Critères de participation
Critère d'éligibilité
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
-
Patient inclusion:
- Adult Patients age >18 years.
- Males or Females
- Patients with good likelihood of recall availability.
Tooth inclusion:
- Permanent anterior teeth with cervical Class V, carious lesions (ICDAS 3-5)
- Vital and with positive reaction to cold stimulus.
- Well-formed and fully erupted teeth.
Exclusion Criteria:
-
Patient exclusion:
- Participants with general/systemic illness.
- Pregnant or lactating females.
- Concomitant participation in another research study.
- Inability to comply with study procedures.
- Heavy Bruxism Habits.
- Last experience with allergic reactions against any components of the used materials.
- Patients receiving orthodontic treatment.
Tooth exclusion:
- Teeth with clinical symptoms of pulpitis such as spontaneous pain or sensitivity to pressure.
- Non-vital teeth, Fractured or cracked teeth.
- Secondary carious lesions.
- Hypocalcified or hypoplastic teeth
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Double
Nombre de bras
Armes et Interventions
Groupe de participants / BrasGroupe de participants / Bras |
Intervention / TraitementIntervention / Traitement |
|---|---|
|
Expérimental: SHOFU FX-LC RMGI
After rubber dam isolation, the prepared cavities will be conditioned using Dentin conditioner (GlasIonomer FX-LC Conditioner, Japan) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance. The (SHOFU FX- LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavities with a capsule gun ensuring that no air bubbles will be included. |
FX-LC is RMGI which incorporates New Generation Acrylamide monomer, After rubber dam isolation, the prepared cavities will be conditioned using Dentin conditioner (GlasIonomer FX-LC Conditioner, Japan) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance. The (SHOFU FX- LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavities with a capsule gun ensuring that no air bubbles will be included. Light curing unit will be used to cure the material for 10 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction. |
|
Comparateur actif: FUJI II RMGI
Cavities will be conditioned using using Dentin conditioner (GC Dentine ConditionerS) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance. The (Fuji II LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavity with a capsule gun ensuring that no air bubbles will be included. light curing unit will be used to cure the material for 20 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction. |
FUJI II, Conventional resin modifies glass ionomer will bwe applied. Cavities will be conditioned using using Dentin conditioner (GC Dentine ConditionerS) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance. The (Fuji II LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavity with a capsule gun ensuring that no air bubbles will be included. light curing unit will be used to cure the material for 20 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction. |
Que mesure l'étude ?
Principaux critères de jugement
Principaux critères de jugement
Mesure des résultats |
Délai |
|---|---|
|
Clinical Performance assessing Biological, Mechanical and Esthetic Parameters Using Modified USPHS Criteria
Délai: Time Frame: Baseline, 6 months, 12 months, 18 months.
|
Time Frame: Baseline, 6 months, 12 months, 18 months.
|
Collaborateurs et enquêteurs
Parrainer
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Début de l'étude
Achèvement primaire (Estimé)
Achèvement primaire
Achèvement de l'étude (Estimé)
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Première publication
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour publiée
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
Autres numéros d'identification d'étude
- 22051999
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .