Clinical Evaluation of SHOFU FX-LC RMGI Restoration Versus FUJI II RGMI in Management of Anterior Carious Cervical Lesions
Clinical Evaluation of Acrylamide Based RMGI Restoration Versus Conventional Resin Modified Glass Ionomer in Management of Patients Having Anterior Carious Cervical Lesions: A Randomized Clinical Trial.
The development of resin-modified glass ionomers (RMGIs) represents a strategic evolution designed to augment the mechanical performance of conventional glass ionomers. By incorporating a resin matrix, these materials achieve notable physical improvements, including superior fracture toughness, increased resistance to occlusal wear, and higher resilience to moisture degradation, alongside the clinical advantage of a prolonged working time. (Hübel 2003)However, an excessive proportion of hydrophobic multifunctional monomers within the RMGI matrix suppresses the essential aqueous acid-base reaction.
To overcome conventional resin modified glass ionomer drawbacks, FX-LC tried to overcome it by incorporating a new multifunctional acrylamide monomer called New Generation Acrylamide monomer (NGA monomer) with which they claim that it exhibits high water solubility due to its four amide bonds (-CO-NH-) and demonstrates high polymerization reactivity, even in the presence of water. It has unique properties that are not found in conventional multifunctional monomers
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Salma hany Nadeem, BDS 2022
- Numero di telefono: (+2)01033719904
- Email: salma.hany@dentistry.cu.edu.eg
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
-
Patient inclusion:
- Adult Patients age >18 years.
- Males or Females
- Patients with good likelihood of recall availability.
Tooth inclusion:
- Permanent anterior teeth with cervical Class V, carious lesions (ICDAS 3-5)
- Vital and with positive reaction to cold stimulus.
- Well-formed and fully erupted teeth.
Exclusion Criteria:
-
Patient exclusion:
- Participants with general/systemic illness.
- Pregnant or lactating females.
- Concomitant participation in another research study.
- Inability to comply with study procedures.
- Heavy Bruxism Habits.
- Last experience with allergic reactions against any components of the used materials.
- Patients receiving orthodontic treatment.
Tooth exclusion:
- Teeth with clinical symptoms of pulpitis such as spontaneous pain or sensitivity to pressure.
- Non-vital teeth, Fractured or cracked teeth.
- Secondary carious lesions.
- Hypocalcified or hypoplastic teeth
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Doppio
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: SHOFU FX-LC RMGI
After rubber dam isolation, the prepared cavities will be conditioned using Dentin conditioner (GlasIonomer FX-LC Conditioner, Japan) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance. The (SHOFU FX- LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavities with a capsule gun ensuring that no air bubbles will be included. |
FX-LC is RMGI which incorporates New Generation Acrylamide monomer, After rubber dam isolation, the prepared cavities will be conditioned using Dentin conditioner (GlasIonomer FX-LC Conditioner, Japan) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance. The (SHOFU FX- LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavities with a capsule gun ensuring that no air bubbles will be included. Light curing unit will be used to cure the material for 10 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction. |
|
Comparatore attivo: FUJI II RMGI
Cavities will be conditioned using using Dentin conditioner (GC Dentine ConditionerS) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance. The (Fuji II LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavity with a capsule gun ensuring that no air bubbles will be included. light curing unit will be used to cure the material for 20 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction. |
FUJI II, Conventional resin modifies glass ionomer will bwe applied. Cavities will be conditioned using using Dentin conditioner (GC Dentine ConditionerS) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance. The (Fuji II LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavity with a capsule gun ensuring that no air bubbles will be included. light curing unit will be used to cure the material for 20 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Clinical Performance assessing Biological, Mechanical and Esthetic Parameters Using Modified USPHS Criteria
Lasso di tempo: Time Frame: Baseline, 6 months, 12 months, 18 months.
|
Time Frame: Baseline, 6 months, 12 months, 18 months.
|
Collaboratori e investigatori
Sponsor
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 22051999
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .