Diaphragm Electrical Activity of Preterm Infants on nCPAP With Binasal Prongs Versus RAM Cannula
Effect of Nasal Continuous Positive Airway Pressure (nCPAP) With RAM Cannula Versus Standard Binasal Prongs on Diaphragm Electrical Activity in Very Low Birth Weight (VLBW) Preterm Infants
Preterm babies have immature lungs and frequent pauses in their breathing which often necessitates breathing support. Nasal Continuous Positive Airway Pressure (nCPAP) is one of the most commonly used tools, but the standard interfaces (prongs or mask) may cause nasal-septal injury and discomfort.
The RAM cannula is another interface that consists in soft and curved prongs to avoid this nasal injury, but as the seal is not 100%, suboptimal delivery of airway distending pressure could result if they are used to deliver CPAP, as compared to standard interfaces.
The investigators plan to study very low birth weight preterm babies who are generally well but require some support with their breathing. By inserting a special feeding tube with sensors into the stomach, the investigators can measure the electrical activity of the diaphragm (EAdi), which is an important muscle for breathing. By analyzing EAdi in babies receiving nCPAP either with prongs or ram cannula, the investigators will be able to measure and compare how each method of support affects a baby's breathing. This important study will help us determine the most appropriate breathing support for preterm babies.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Continuous Positive Airway Pressure is one of the most researched and accepted methods of delivering NIV to term and preterm infants. Different interfaces have been used, most frequently binasal prongs or mask. The RAM cannula is a relatively new interface for delivering CPAP in preterm infants, specially to avoid nasal injury and discomfort. However, there are few studies in artificial models with different results in term of the percentage of pressure that is really delivered when we use the RAM cannula. The objective of this study is to to investigate in VLBW preterm infants who require respiratory support by nasal CPAP, whether or not using the RAM cannula as the interface will allow to provide the level of respiratory support equivalent to that with the traditional binasal prongs, measured by diaphragm electrical activity (Edi). The investigators hypothesize that in VLBW preterm infants with respiratory distress syndrome (RDS), the use of CPAP with RAM cannula as the interface may provide lower PEEP (positive end expiratory pressure) than set and increased resistance to gas flow, leading to increased respiratory effort for the patient as reflected by an increase in Edi.
This study will help Neonatologist determine if the amount of support provided with the RAM cannula as interface is equivalent to the support we achieve with the standard interfaces, to select the patients that could benefit from using this interface. The investigators will be able to utilize this information to decide on the most appropriate respiratory support modality for preterm patients.
Type d'étude
Inscription (Anticipé)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
Ontario
-
Toronto, Ontario, Canada, M4N3M5
- Recrutement
- Sunnybrook Health Science Centre
-
Contact:
- Michael Dunn, MD
- Numéro de téléphone: 87777 (416) 480-6100
- E-mail: michael.dunn@sunnybrook.ca
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Clinically stable preterm infants (defined as: cardiovascular stability with normal blood pressure and heart rate for GA and no recent increase in apneic episodes or spells and confirmed by the attending neonatologist) with birth weights less than 1500 gr and/or gestational age bellow 32 weeks, admitted to the NICU at Sunnybrook Health Sciences Centre on nasal continuous positive airway pressure of 5 to 8 cmH20 support, for at least 48 h and requiring less than 35% of oxygen.
Exclusion Criteria:
- Infants with congenital anomalies of the gastrointestinal tract, phrenic nerve damage, diaphragmatic paralysis, esophageal perforation; infants with congenital or acquired neurological deficit (including significant intraventricular hemorrhage greater than Grade II), neonatal seizure; infants with significant congenital heart disease (including symptomatic PDA); infant with congenital anomalies of the diaphragm; infant with congenital anomalies of the respiratory tracts (e.g. Congenital Cystic Adenomatoid Malformation (CCAM)) infants requiring ongoing treatment for sepsis, necrotizing enterocolitis (NEC), antibiotics for lung infections, narcotic analgesics, or gastric motility agents will be excluded. Infants on nasal CPAP and requiring more than 35% oxygen will be excluded from the study. Infants with significant gastric residuals and vomiting, infants with facial anomalies, infants with pneumothorax or pneumomediastinum, and infants in the immediate postoperative period will be excluded. Infants with nasal excoriations will be excluded from the study as they may be electively placed on the RAM cannula to prevent further nasal trauma.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation croisée
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
---|---|
Comparateur actif: CPAP with binasal prongs
Edi will be recorded while the infant is on nasal CPAP with the binasal prongs, with a PEEP of 5-8 cm H2O, for 2 hours.
Then, the infant will be switched the interface to the RAM cannula, with a PEEP 2 cmH2O higher, during 2 hours.
|
change interface to RAM cannula
change interface to binasal prongs
|
Comparateur actif: CPAP with RAM cannula
Edi will be recorded while the infant is on nasal CPAP with the RAM cannula with a PEEP 2 cmH20 higher than the levels the infant was receiving before starting the study protocol, for 2 hours.
Then, the infant will be switched the interface to the binasal prongs with a PEEP between 5-8 cmH2O, during 2 hours.
|
change interface to RAM cannula
change interface to binasal prongs
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
Differences in Edi min between CPAP with binasal prongs versus with the RAM cannula
Délai: 4 hours
|
Measured by the electrical activity of the diaphragm between respiratory support modes (nCPAP with binasal prongs and RAM cannula)
|
4 hours
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
Difference in neural respiratory rate
Délai: 4 hours
|
Measured by the electrical activity of the diaphragm between respiratory support modes (nCPAP with binasal prongs and RAM cannula).
|
4 hours
|
Difference in neural inspiratory time
Délai: 4 hours
|
Measured by the electrical activity of the diaphragm between respiratory support modes (nCPAP with binasal prongs and RAM cannula).
|
4 hours
|
Difference in Edi peak
Délai: 4 hours
|
Measured by the electrical activity of the diaphragm between respiratory support modes (nCPAP with binasal prongs and RAM cannula).
|
4 hours
|
Difference in transcutaneous pCO2
Délai: 4 hours
|
Measured difference in transcutaneous pCO2 between the 2 different respiratory support modes(nCPAP with binasal prongs and RAM cannula).
|
4 hours
|
Difference in number of apnea episodes
Délai: 4 hours
|
Difference in number of apnea episodes between the 2 different respiratory support modes (nCPAP with binasal prongs and RAM cannula).
|
4 hours
|
Needs of oxygen
Délai: 4 hours
|
Needs of O2 measured by FiO2 on the 2 different respiratory support modes (nCPAP with binasal prongs and RAM cannula).
|
4 hours
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Michael Dunn, MD, Staff Neonatologist - NICU
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Anticipé)
Achèvement de l'étude (Anticipé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
- Maladies des voies respiratoires
- Troubles respiratoires
- Maladies pulmonaires
- Nourrisson, nouveau-né, maladies
- Complications de grossesse
- Complications du travail obstétrical
- Travail obstétrique, prématuré
- Nourrisson, Prématuré, Maladies
- Naissance prématurée
- Syndrome de détresse respiratoire
- Syndrome de détresse respiratoire, nouveau-né
Autres numéros d'identification d'étude
- RAM cannula study
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .
Essais cliniques sur Les nourrissons prématurés
-
Georgetown UniversityComplétéParental Infant Bonding | Stabilité cardio-respiratoire chez les nourrissons prématurés de l'USINÉtats-Unis
Essais cliniques sur respiratory support- interface
-
QIAGEN Gaithersburg, IncComplétéMaladie respiratoireRoyaume-Uni
-
Guy's and St Thomas' NHS Foundation TrustPhilips HealthcareComplété
-
Tufts Medical CenterComplétéObésité | Apnée obstructive du sommeilÉtats-Unis