Factors Contributing to the Pressure Wave Form Changes
Analysis of Factors Contributing to the Pressure Wave Form Changes During Lumbar Epidural Injections
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Loss of resistance (LOR) is the most commonly used method to confirm the epidural space. The advantage of LOR is its simplicity; only saline or air filled syringe is required. LOR is felt through the sudden decrease of pressure and this pressure gradient is generated when the needle is within the passage of interspinous ligament, ligamentum flavum and epidural space. The presence of ligamentum flavum is crucial for the identification of epidural space by LOR. However, gaps in ligamentum flavum, paravertebral muscle and cyst in interspinous ligament can modify this passage and a false LOR is generated consequentially. The false positive rate of the lumbar and cervical area was reported to be 8.3~17% and 30~68%, respectively. If the false positive rate is high, repeated attempts of epidural steroid injection (ESI) are required, with additional discomfort or pain to the patient.
The high rate of false LOR has prompted the design of adjunctive modalities. Among these, epidural pressure waveform analysis (EPWA) using pressure transducer has been reported. If the epidural needle or catheter is positioned accurately in the epidural space, a pulsatile wave coinciding with arterial pulsations can be seen through the monitor.
Recent study suggested that significant abrupt pressure decrease occurs when cervical epidural injection was done via paramedian approach rather than midline.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Daegu, Corée, République de, 700712
- Ji Hee Hong
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- lumbar herniated nucleus
- lumbar spinal stenosis
- internal disc disruption
- NRS > 5
- ODI > 20
Exclusion Criteria:
- coagulopathy
- allergy to contrast media
- infection at needle insertion site
- absence of lumbar MRI
- Pregnancy
- previous lumbar spine surgery
- neurological symptoms requiring prompt reevalution
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Seul
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
---|---|
Comparateur actif: Lumbar ESI with paramedian approach
|
the pattern of pressure decrease from ligamentum flavum to epidural space
|
Comparateur actif: Lumbar ESI with midline approach
|
the pattern of pressure decrease from ligamentum flavum to epidural space
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
pattern of epidural pressure decrease
Délai: 1 second after the completion of entry from ligamentum flavum to epidural space
|
abrupt or gradual decrease of epidural pressure
|
1 second after the completion of entry from ligamentum flavum to epidural space
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
factors contributing the epidural pressure pattern
Délai: 60 minutes after the completion of entry from ligamentum flavum to epidural space
|
factors contributing the epidural pressure decrease(abrupt vs. gradual) pattern
|
60 minutes after the completion of entry from ligamentum flavum to epidural space
|
Collaborateurs et enquêteurs
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Autres numéros d'identification d'étude
- 2017-05-039
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .
Essais cliniques sur lumbar epidural injection
-
Zongxun LinRecrutement
-
Jiangsu HengRui Medicine Co., Ltd.Complété
-
Jiangsu HengRui Medicine Co., Ltd.Complété
-
Jiangsu HengRui Medicine Co., Ltd.Pas encore de recrutement
-
Royan InstituteComplétéInfarctus du myocardeIran (République islamique d
-
Dalia Salah SaifInconnuePR - Polyarthrite rhumatoïdeEgypte
-
Wuhan Neurophth Biotechnology Limited CompanyRecrutementNeuropathie optique héréditaire de Leber (NOHL)Chine
-
Fidia Farmaceutici s.p.a.RecrutementDiscopathie dégénérative (DDD)Italie, Suisse
-
Qilu Pharmaceutical Co., Ltd.Actif, ne recrute pasTumeurs solides avancéesChine
-
Taipei Medical University WanFang HospitalInconnue