Does Parathyroid Autofluorescence Reduces Unintensional Parathyroidectomy During Total Thyroidectomy With Central Lymph Node Compartment Dissection (FLUOBCC)
The aim of the study is to evaluate the effectiveness of autofluorescence in the intraoperative preservation of parathyroids during total thyroidectomy with central lymph node compartment dissection.
Aperçu de l'étude
Statut
Description détaillée
Real-time intraoperative identification and functional maintenance of structures are of major importance in endocrine surgery, with a critical role in clinical outcomes and patients' quality of life. Despite the advances in preoperative imaging techniques, there is still need for precise intraoperative visualizing [1]. Limitations of naked eye inspection and subjectivity of palpation are imposing challenges even for the most experienced surgeons [1-3]. Nowadays, attention is attracted to intraoperative imaging techniques using Near Infrared Fluorescence (NIRF) with endogenous or exogenous contrast agents. These imaging techniques are attractive in biomedicine due to its high penetration depth and low scattering in human tissue [2].
Autofluorescence is the ability of several natural substances or drugs to be fluorescent after the absorbance of light or radiation. It has been already proved that parathyroid glands emit their own light after near-infrared (NIR) around 820nm , providing high contrast to the surrounding tissues. This made near-infrared autofluorescence a potential useful tool in hands of experienced endocrine surgeons in order to distinguish parathyroid glands from other anatomic structures during thyroidectomies.
Approximately 7.6% of thyroid surgeries resulted in hypoparathyroidism, with 75% of these cases being transient and 25% being chronic. The mechanisms that underlie hypoPTH are related to disruption of parathyroid arterial supply or venous drainage, mechanical injury, thermal or electrical injury, and either intentional or inadvertent partial or complete removal.
The aim of the present study is to evaluate the value of intra-operative autofluorescence imaging concerning the unintentional excision rate of parathyroids during total thyroidectomy with central lymph node compartment dissection. Moreover, we are going to evaluate correlation of autofluorescence with 24 hours post-operative PTH.
Type d'étude
Inscription (Réel)
Contacts et emplacements
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
Our sample size of 180 patients has been calculated after power analysis regarding other similar studies with an a=0.05 and Power=0.95.
La description
Inclusion Criteria:
- Patient is over 18 years old
- Patient scheduled for a non-emergency operation
- Patient eligible for total thyroidectomy
Exclusion Criteria:
- Patient is participating in another clinical trial which may affect this study's outcomes
- Prior operation in the neck
- Primary or secondary hyperparathyroidism
- Vitamin D deficiency
- Use of drugs that influences calcium metabolism (Vitamin D analogues, oral calcium supplements, bisphosphonates, teriparatide, thiazide diuretics, aromatase inhibitors)
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Modèles d'observation: COHORT
- Perspectives temporelles: PROSPECTIVE
Cohortes et interventions
Groupe / Cohorte |
|---|
|
Autofluorescence
The surgeon will perform the preplanned thyroidectomy with central lymph node compartment dissection with FLUOBEAM XS. The following intraoperative variables will be recorded for all patients: Surgery date Duration of surgery Operation performed Procedure related comments Number and location of the visualized glands Intra-operative autofluorescence score (either 0 (no visualization or 1 visualization) for each gland |
|
Control
The surgeon will perform the preplanned thyroidectomy with central lymph node compartment dissection without autofluorescence device. The following intraoperative variables will be recorded for all patients: Surgery date Duration of surgery Operation performed Procedure related comments Number and location of the visualized glands |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
The contribution of intra-operative autofluorescence imaging on unintentional excision rate of parathyroids during total thyroidectomy with central lymph node dissection
Délai: 6 months
|
The aim of the study is to evaluate the use of autofluorescence to distinguish parathyroid glands during thyroidectomy with central lymph node dissection (TTCC). We will measure the number of parathyroids accidentally excised during TTCC with and without autofluorescence. |
6 months
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Detecting the changes of practice in performing total thyroidectomywith central lymph node dissection when monitoring parathyroids with autofluorescence.
Délai: 6 months
|
If autofluorescence is proved to be a useful tool in endocrine surgeons hands, the preservation of parathyroid glands during thyroidectomy with central lymph node dissection would be easier. |
6 months
|
|
Correlating autofluorescence with 24 hours post-operative PTH.
Délai: 6 months
|
To identify any correlation between intra-operative parathyroid glands autofluorescence with postoperative hypoparathyroidism. We are going to evaluate the number of parathyroids evaluated and we are going to correlate it with PTH. |
6 months
|
|
Correlating autofluorescence with postoperative hypocalcemia
Délai: 7months
|
To identify any correlation between intra-operative parathyroid glands autofluorescence with postoperative hypoparathyroidism. We are going to evaluate the number of parathyroids evaluated and we are going to correlate it with Ca. |
7months
|
|
Identifying and analyzing problematic groups of patients
Délai: 7 months
|
This study will sign out the disadvantages of FLUOBEAM XS or cases that its use should be avoided. |
7 months
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Theodossis Papavramidis, MD, PhD, AHEPA University Hospital of Thessaloniki, Greece
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- FLUOBCC
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .