Methods for the Measurement of Respiratory Rate
This study aims to investigate these research questions:
- Is there a difference in the results obtained, when respiratory rate is measured automatically by an electronic device (SensiumVitals® system, Sensium Healthcare) compared with a research assistant using a criterion standard approach?
- Is there a difference in the results obtained, when respiratory rate is measured automatically by an electronic device (SensiumVitals® system, Sensium Healthcare) compared with hospital staff's current clinical practice?
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Részletes leírás
Respiratory rate is among the first vital signs to change when a deterioration in patient conditions occurs, and that it is highly useful in identifying high-risk patients, patients in pain, risk of death in patients treated for myocardial infarctions and medical patients at risk of cardiac arrest.
Respiratory rate is one of the seven physiological parameters included in the Early Warning Score (EWS), an aggregated track- and trigger-system for risk-stratification of patients in hospital wards at risk of imminent clinical deterioration. EWS includes an escalation protocol, defining when it is necessary for the ward staff to call for assistance and when vital parameters should be measured again.
Manual measurement of respiratory rates is the standard in hospital wards in the Capital Region of Denmark. During the measurement of respiratory rate, patients ideally have to lie still and refrain from talking. This poses a difficulty in daily, clinical practice. Several studies in hospital wards both using and not using an EWS-system report that respiratory rate is often omitted when vital signs are measured.
Even if the respiratory rate is measured regularly, poor inter-observer agreement and reproducibility of measured respiratory rates have been found. Respiratory rates recorded by nurses have been reported to be generally higher than those measured by observers using a standardised approach.
The EWS currently in use is validated using measurements obtained by normal nursing practise. If there is an element of human influence on the measurement of respiratory rate, automation could affect the prognostic properties of EWS in an unpredictable way, even if the automatically measured respiratory rates more reliably reflect the patients' physiology than current clinical practise.
If a systematic difference between the recordings by staff and the electronic devices currently on the market exists, this could have an implication on the EWS scores and subsequently, escalation protocols for patients with elevated EWS could be affected. If this is the case, EWS might even have to be re-validated using machine-measured respiratory rates.
Thus, even as there could be a number of advantages of automating the measurements of respiratory rates in hospital wards, due considerations are required before ward staff's manual measurement of respiratory rate can be replaced by measurements obtained from electronic devices. The purpose of this study is to evaluate if there is a systematic difference in the respiratory rate measurements performed by an electronic device (SensiumVitals® system, Sensium Healthcare) compared with the measurements performed by a research assistant using a criterion standard approach and the ward staff's usual measurements.
Tanulmány típusa
Beiratkozás (Tényleges)
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi helyek
-
-
-
Herlev, Dánia, 2730
- Copenhagen Academy for Medical Education and Simulation and Medical-Short Time Ward, Herlev Hospital
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Leírás
Inclusion Criteria:
- Age 18 years or older.
- Able and willing to give informed consent to participation in the study and necessary data collection.
- Admitted to the general medical short-time ward and planned stay there at the time of inclusion greater than two hours.
Exclusion Criteria:
- Wounds, burns or other conditions that prevent proper attachment of the measurement device, or where wearing the device might cause or increase discomfort from wearing the device.
- Allergies to medical graded tape or ECG electrodes.
- Patients with cardiac pacemaker or implanted defibrillator.
- Any condition or situation preventing proper information, consent and enrolment.
- Respiratory rate measurements by another device using impedance pneumography.
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Diagnosztikai
- Kiosztás: N/A
- Beavatkozó modell: Egyetlen csoportos hozzárendelés
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
---|---|
Egyéb: Included patients
All included patients will have respiratory rates measured by a research assistant using a criterion standard approach, by the SensiumVitals device and by the ward staff.
|
The patients will have their respiratory rates, heart rates and temperature (axilla) measured continuously by the SensiumVitals patch.
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
---|---|---|
Difference in respiratory rate recorded by the research assistant using a criterion standard approach and the SensiumVitals device
Időkeret: 24 Hours
|
After enrolment at the general, medical short-time ward a research assistant will measure the patient's respiratory rate using a criterion standard approach.
The time of this measurement will be registered, and the corresponding measurement made by the SensiumVitals device will be extracted and used for the comparison.
Reported with Bland-Altman plots.
|
24 Hours
|
Másodlagos eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
---|---|---|
Difference in respiratory rate recorded by the ward staff using standard clinical practice and the SensiumVitals device
Időkeret: 24 Hours
|
The ward staff's first measurement of respiratory rate after the patient is enrolled in the study at the general, medical short-time ward as registered in the electronic patient journal.
The time of this measurement will be registered, and the corresponding measurement made by the SensiumVitals device will be extracted and used for the comparison.
Reported with Bland-Altman plots.
|
24 Hours
|
Egyéb eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
---|---|---|
Early Warning Score recorded by the research assistant
Időkeret: 24 Hours
|
Early Warning Score (point score) will be recorded using standard practice by the research assistant.
Parameters included in the Early Warning Score: Peripheal arterial oxygen satuation (%), pulse (beats per minute), use of supplementary oxygen (liters per minute), systolic and diastolic blood pressure (mmHg), level of consciousness (AVPU-scale), temperature (degrees celcius) and pulse regularity (yes/no).
|
24 Hours
|
Early Warning Score recorded by the ward staff
Időkeret: 24 Hours
|
Early Warning Score (point score) recorded using standard practice by the ward staff.
Early Warning Score consists of: Peripheal arterial oxygen satuation (%), pulse (beats per minute), use of supplementary oxygen (liters per minute), systolic and diastolic blood pressure (mmHg), level of consciousness (AVPU-scale) and temperature (degrees celcius).
|
24 Hours
|
Együttműködők és nyomozók
Szponzor
Nyomozók
- Kutatásvezető: Niels E Pedersen, MD, Copenhagen Academy for Medical Education and Simulation, Herlev Hospital, Center for HR, Capital Region of Denmark
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete
Elsődleges befejezés (Tényleges)
A tanulmány befejezése (Tényleges)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Becslés)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Becslés)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
Kulcsszavak
Egyéb vizsgálati azonosító számok
- CAMES-16-001
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .
Klinikai vizsgálatok a SensiumVitals
-
Imperial College LondonIsmeretlenVérmérgezés | Leromlás, KlinikaiEgyesült Királyság