Clinical Assessment of a Customized Free-form Progressive Addition Lens Spectacle (CZV_PAL1)

17 aprile 2017 aggiornato da: Meng C. Lin, University of California, Berkeley
The purpose of this study was to compare objective clinical measures of visual performance and subjective measures of satisfaction and preference between standard progressive addition lens (PAL) spectacles and a new type of free-form surfaced, optically customized PAL spectacle.

Panoramica dello studio

Stato

Completato

Condizioni

Intervento / Trattamento

Descrizione dettagliata

In a double-masked crossover trial, 95 experienced wearers wore customized free-form PAL spectacles (Test) and standard non-free-form PAL spectacles (Control) for one week each. All subjects wore both Test and Control spectacles, and the pair to be worn first was randomly assigned. At dispensing and after 1 week of wear, subjects were tested for distance and near visual acuity (VA) under both high and low contrast; in addition, 30 degree off-axis VA was measured using a novel apparatus, as was the horizontal extent of undistorted vision at reading distance. Subjects also completed a set of questionnaires detailing their satisfaction levels, adaptation times, and preferences for Test or Control spectacles for different visual tasks.

Tipo di studio

Interventistico

Iscrizione (Effettivo)

95

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • California
      • Berkeley, California, Stati Uniti, 94720-2020
        • Clinical Research Center, School of Optometry, University of California, Berkeley

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 39 anni a 80 anni (Adulto, Adulto più anziano)

Accetta volontari sani

Sì

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Presbyope
  • Experienced PAL spectacle wearer
  • Correctable to at least 20/25 in both eyes
  • Able and willing to use Test and Control spectacles for 1 week each as primary form of presbyopia correction
  • Able and willing to complete all laboratory measurements and questionnaire batteries

Exclusion Criteria:

  • Purchasing free-form PAL spectacles from the UC Berkeley Eyewear Center
  • Having eye conditions or diseases that could potentially cause a decrease in visual acuity over the course of participation in the study
  • Having eye conditions or diseases that could potentially interfere with ability to use Test and Control spectacles as primary form of presbyopia correction

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione incrociata
  • Mascheramento: Doppio

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Comparatore attivo: Randomized Order of Interventions 1
Randomized to first wear standard, non-free-form, non-customized PAL spectacles, then second, crossover to wear individually customized free-form surfaced PAL spectacles
Control spectacles include several different PAL brands as selected by patients in the UC Berkeley Optometry Clinic and purchased in the Eyewear Center; after successful fitting and purchase, potential subjects were recruited for the trial.
Test spectacles are Zeiss Individual, free-form surfaced, and customized using the iTerminal device to account for individual back vertex distance, wrap angle and pantoscopic tilt
Altri nomi:
  • Zeiss Individual, Carl Zeiss Vision, Inc., Germany
Comparatore attivo: Randomized Order of Interventions 2
Randomized to first wear individually customized free-form surfaced PAL spectacles, then second, crossover to wear standard, non-free-form, non-customized PAL spectacles
Control spectacles include several different PAL brands as selected by patients in the UC Berkeley Optometry Clinic and purchased in the Eyewear Center; after successful fitting and purchase, potential subjects were recruited for the trial.
Test spectacles are Zeiss Individual, free-form surfaced, and customized using the iTerminal device to account for individual back vertex distance, wrap angle and pantoscopic tilt
Altri nomi:
  • Zeiss Individual, Carl Zeiss Vision, Inc., Germany

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Visual Acuity, High Contrast, Distance Chart
Lasso di tempo: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Standard assessment of high contrast visual acuity at distance, as in normal clinical practice, using Baily-Lovey charts and the M&S Technologies Smart System II visual acuity projection system.
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Visual Acuity, Low Contrast, Distance Chart
Lasso di tempo: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Standard assessment of low contrast visual acuity at distance, as in normal clinical practice, using Baily-Lovey charts and the M&S Technologies Smart System II visual acuity projection system.
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Visual Acuity, High Contrast, Near Chart
Lasso di tempo: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Standard assessment of high contrast visual acuity at near, as in normal clinical practice, using Baily-Lovey charts and the M&S Technologies Smart System II visual acuity projection system.
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Visual Acuity, Low Contrast, Near Chart
Lasso di tempo: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Standard assessment of low contrast visual acuity at near, as in normal clinical practice, using Baily-Lovey charts and the M&S Technologies Smart System II visual acuity projection system.
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
30-degree Off-axis Distance Visual Acuity, High Contrast Chart
Lasso di tempo: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Measured with subject immobilized in specially designed apparatus, keeping head pointed straight forward and moving only the eyes to left or right to view the off-axis chart
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
30-degree Off-axis Distance Visual Acuity, Low Contrast Chart
Lasso di tempo: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Measured with subject immobilized in specially designed apparatus, keeping head pointed straight forward and moving only the eyes to left or right to view the off-axis chart
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Horizontal Extent of Undistorted Vision at Reading Distance
Lasso di tempo: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Novel apparatus designed to immobilize head and allow subject to indicate point of peripheral optical distortion on a modified Amsler-type grid
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Questionnaire Battery
Lasso di tempo: At study exit, after both Test and Control spectacles had been worn for 1 week each
Forced-choice Likert scale preference questionnaire
At study exit, after both Test and Control spectacles had been worn for 1 week each

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Collaboratori

Investigatori

  • Investigatore principale: Meng C. Lin, OD, PhD, Clinical Research Center, School of Optometry, University of California, Berkeley

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio

1 febbraio 2009

Completamento primario (Effettivo)

1 ottobre 2009

Completamento dello studio (Effettivo)

1 ottobre 2009

Date di iscrizione allo studio

Primo inviato

3 novembre 2010

Primo inviato che soddisfa i criteri di controllo qualità

3 novembre 2010

Primo Inserito (Stima)

4 novembre 2010

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

18 aprile 2017

Ultimo aggiornamento inviato che soddisfa i criteri QC

17 aprile 2017

Ultimo verificato

1 aprile 2017

Maggiori informazioni

Termini relativi a questo studio

Termini MeSH pertinenti aggiuntivi

Altri numeri di identificazione dello studio

  • CZV_PAL1

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .