Cirrus HD-OCT Measurement of Area of Increased Light Penetration Under the Retinal Pigment Epithelium (RPE)
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Descrizione dettagliata
Specific Objectives:
- To compare Cirrus HD-OCT automated measurements of the illumination area under the RPE to expert manual measurements of areas of hypofluorescence typical of geographic atrophy in fundus autofluorescence (FAF) images.
- To describe the differences and similarities between Cirrus HD-OCT and fundus autofluorescence images of subjects with geographic atrophy secondary to dry age-related macular degeneration (AMD).
- To determine the clinical factors that affect the Cirrus HD-OCT automated measurements of the illumination area under the RPE.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Contatti e Sedi
Luoghi di studio
-
-
California
-
Oakland, California, Stati Uniti, 94609
- East Bay Retina Consultants, Inc.
-
-
Michigan
-
Jackson, Michigan, Stati Uniti, 49202
- TLC Eyecare and Laser Centers
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Males or females 50 years of age and older diagnosed to have advanced dry AMD with geographic atrophy.
Geographic atrophy lesions should:
- Not be greater than 5 mm at the widest diameter. The entire lesion(s) should fit into the 6x6 mm scan area of the Cirrus HD-OCT.
- Not be smaller than 1.25 mm2.
- Not be confluent with peri-papillary atrophy.
- Not be combined with other lesions such as CNVs.
- Able and willing to make the required study visit.
- Able and willing to give consent and follow study instructions.
Exclusion Criteria:
- History of retinal surgery, laser photocoagulation, and/or radiation therapy to the eye.
- Evidence of other retinal diseases of the eye, including wet AMD, diabetic retinopathy, diabetic macular edema, or significant vitreomacular traction upon dilated examination, or upon evaluation of retinal photos.
- Thick media opacity or inability to fixate that precludes obtaining acceptable scans.
- Concomitant use of hydrochloroquine and chloroquine.
- Unable to make the required study visit.
- Unable to give consent or follow study instructions.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
|---|
|
Dry AMD and geographic atrophy
Patients diagnosed with dry AMD and geographic atrophy
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Difference in mm Squared of Cirrus HD-OCT Automated Measurements of the Illumination Areaa Under the RPE to Expert Manual Measurement of Areas of Hypofluorescence Typical of Geographic Atrophy (GA).
Lasso di tempo: August 2011
|
In retinal areas with atrophy, light emitted from the Cirrus penetrates the sclera and choroid which are more reflecting compared with the Retinal Pigment Epithelium (RPE).
The areas with higher illumination are associated with areas of Geographic Atrophy (GA), and allow to quantify how big is the area of atrophy.
The study will assess the difference between Cirrus HD-OCT measurements of areas of increased illumination under the RPE to hypofluorescence areas on fundus photos as assessed manually by retina specialists.
|
August 2011
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Carmelina M Gordon, MD, TLC Eye Care and Laser Center
- Investigatore principale: Eugene S Lit, M.D., East Bay Retina Consultants
Pubblicazioni e link utili
Pubblicazioni generali
- Holz FG, Bindewald-Wittich A, Fleckenstein M, Dreyhaupt J, Scholl HP, Schmitz-Valckenberg S; FAM-Study Group. Progression of geographic atrophy and impact of fundus autofluorescence patterns in age-related macular degeneration. Am J Ophthalmol. 2007 Mar;143(3):463-72. doi: 10.1016/j.ajo.2006.11.041. Epub 2006 Dec 22.
- Schmitz-Valckenberg S, Fleckenstein M, Scholl HP, Holz FG. Fundus autofluorescence and progression of age-related macular degeneration. Surv Ophthalmol. 2009 Jan-Feb;54(1):96-117. doi: 10.1016/j.survophthal.2008.10.004.
- Hwang JC, Chan JW, Chang S, Smith RT. Predictive value of fundus autofluorescence for development of geographic atrophy in age-related macular degeneration. Invest Ophthalmol Vis Sci. 2006 Jun;47(6):2655-61. doi: 10.1167/iovs.05-1027.
- Lujan BJ, Rosenfeld PJ, Gregori G, Wang F, Knighton RW, Feuer WJ, Puliafito CA. Spectral domain optical coherence tomographic imaging of geographic atrophy. Ophthalmic Surg Lasers Imaging. 2009 Mar-Apr;40(2):96-101. doi: 10.3928/15428877-20090301-16.
- Sunness JS, Margalit E, Srikumaran D, Applegate CA, Tian Y, Perry D, Hawkins BS, Bressler NM. The long-term natural history of geographic atrophy from age-related macular degeneration: enlargement of atrophy and implications for interventional clinical trials. Ophthalmology. 2007 Feb;114(2):271-7. doi: 10.1016/j.ophtha.2006.09.016.
- Yehoshua Z, Rosenfeld PJ, Gregori G, Feuer WJ, Falcao M, Lujan BJ, Puliafito C. Progression of geographic atrophy in age-related macular degeneration imaged with spectral domain optical coherence tomography. Ophthalmology. 2011 Apr;118(4):679-86. doi: 10.1016/j.ophtha.2010.08.018. Epub 2010 Oct 29.
Studiare le date dei record
Studia le date principali
Inizio studio
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- HD-OCT-GA-2010-1-v2
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .