Specific Objectives:
- To compare Cirrus HD-OCT automated measurements of the illumination area under the RPE to expert manual measurements of areas of hypofluorescence typical of geographic atrophy in fundus autofluorescence (FAF) images.
- To describe the differences and similarities between Cirrus HD-OCT and fundus autofluorescence images of subjects with geographic atrophy secondary to dry age-related macular degeneration (AMD).
- To determine the clinical factors that affect the Cirrus HD-OCT automated measurements of the illumination area under the RPE.
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Contactos e Locais
Locais de estudo
-
-
California
-
Oakland, California, Estados Unidos, 94609
- East Bay Retina Consultants, Inc.
-
-
Michigan
-
Jackson, Michigan, Estados Unidos, 49202
- TLC Eyecare and Laser Centers
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- Males or females 50 years of age and older diagnosed to have advanced dry AMD with geographic atrophy.
Geographic atrophy lesions should:
- Not be greater than 5 mm at the widest diameter. The entire lesion(s) should fit into the 6x6 mm scan area of the Cirrus HD-OCT.
- Not be smaller than 1.25 mm2.
- Not be confluent with peri-papillary atrophy.
- Not be combined with other lesions such as CNVs.
- Able and willing to make the required study visit.
- Able and willing to give consent and follow study instructions.
Exclusion Criteria:
- History of retinal surgery, laser photocoagulation, and/or radiation therapy to the eye.
- Evidence of other retinal diseases of the eye, including wet AMD, diabetic retinopathy, diabetic macular edema, or significant vitreomacular traction upon dilated examination, or upon evaluation of retinal photos.
- Thick media opacity or inability to fixate that precludes obtaining acceptable scans.
- Concomitant use of hydrochloroquine and chloroquine.
- Unable to make the required study visit.
- Unable to give consent or follow study instructions.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Número de grupos/coortes
Coortes e Intervenções
Grupo / CoorteGrupo / Coorte |
|---|
|
Dry AMD and geographic atrophy
Patients diagnosed with dry AMD and geographic atrophy
|
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Difference in mm Squared of Cirrus HD-OCT Automated Measurements of the Illumination Areaa Under the RPE to Expert Manual Measurement of Areas of Hypofluorescence Typical of Geographic Atrophy (GA).
Prazo: August 2011
|
In retinal areas with atrophy, light emitted from the Cirrus penetrates the sclera and choroid which are more reflecting compared with the Retinal Pigment Epithelium (RPE).
The areas with higher illumination are associated with areas of Geographic Atrophy (GA), and allow to quantify how big is the area of atrophy.
The study will assess the difference between Cirrus HD-OCT measurements of areas of increased illumination under the RPE to hypofluorescence areas on fundus photos as assessed manually by retina specialists.
|
August 2011
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Investigador principal: Carmelina M Gordon, MD, TLC Eye Care and Laser Center
- Investigador principal: Eugene S Lit, M.D., East Bay Retina Consultants
Publicações e links úteis
Publicações Gerais
- Holz FG, Bindewald-Wittich A, Fleckenstein M, Dreyhaupt J, Scholl HP, Schmitz-Valckenberg S; FAM-Study Group. Progression of geographic atrophy and impact of fundus autofluorescence patterns in age-related macular degeneration. Am J Ophthalmol. 2007 Mar;143(3):463-72. doi: 10.1016/j.ajo.2006.11.041. Epub 2006 Dec 22.
- Schmitz-Valckenberg S, Fleckenstein M, Scholl HP, Holz FG. Fundus autofluorescence and progression of age-related macular degeneration. Surv Ophthalmol. 2009 Jan-Feb;54(1):96-117. doi: 10.1016/j.survophthal.2008.10.004.
- Hwang JC, Chan JW, Chang S, Smith RT. Predictive value of fundus autofluorescence for development of geographic atrophy in age-related macular degeneration. Invest Ophthalmol Vis Sci. 2006 Jun;47(6):2655-61. doi: 10.1167/iovs.05-1027.
- Lujan BJ, Rosenfeld PJ, Gregori G, Wang F, Knighton RW, Feuer WJ, Puliafito CA. Spectral domain optical coherence tomographic imaging of geographic atrophy. Ophthalmic Surg Lasers Imaging. 2009 Mar-Apr;40(2):96-101. doi: 10.3928/15428877-20090301-16.
- Sunness JS, Margalit E, Srikumaran D, Applegate CA, Tian Y, Perry D, Hawkins BS, Bressler NM. The long-term natural history of geographic atrophy from age-related macular degeneration: enlargement of atrophy and implications for interventional clinical trials. Ophthalmology. 2007 Feb;114(2):271-7. doi: 10.1016/j.ophtha.2006.09.016.
- Yehoshua Z, Rosenfeld PJ, Gregori G, Feuer WJ, Falcao M, Lujan BJ, Puliafito C. Progression of geographic atrophy in age-related macular degeneration imaged with spectral domain optical coherence tomography. Ophthalmology. 2011 Apr;118(4):679-86. doi: 10.1016/j.ophtha.2010.08.018. Epub 2010 Oct 29.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- HD-OCT-GA-2010-1-v2
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .