Observational Study to Assess Oxygen Saturation Predictive Power Related to Intradialytic Acute Hypotension (SOGLIA)
Italian Group of Study on the Role of Oxygen Saturation as a Potential Surrogate Marker of Intradialytic Cardiovascular Instability
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
During the last 40 years a lot has been achieved in dialysis regarding both monitors safety and membranes overall performances Anyway, intradialytic symptoms still remain a major concern for nephrologists: in particular, hypotension is the most frequent [1].
Intradialytic hemodynamic monitoring systems have been developed to have continuous surveillance of the main hemodynamic variables (heart rate, body temperature, blood pressure itself, cardiac output, ecc…).
In a second moment, the further evolution was towards the retroactive control systems, to force some of the variables involved in the genesis of the hemodynamic stability, along a pre-determined, ideal, trend. In this view, various bio-feedback mechanisms have been proposes along the years, for example, to tackle hypovolemia-related hypotension. Their scientific rationale is the control of either blood volume or directly natremia, in order to pilot plasma refilling towards the vascular compartment [2].
Despite the great achievements obtained, the forecasting of acute hypotension during hemodialysis still remains a complex problem, likely involving more than one variable.
SO2 can be considered an indirect expression of the hemodynamic stability. Moreover, in dialysis, it has always been regarded as a bio-compatibility marker for membranes [3]. Nowadays, SO2 changes during dialysis are easy to measure with a fully, non-invasive sensor assembled on the arterial line.
We planned this study to analyze on a large number of sessions the short-term variability of SO2 during hemodialysis in relationship with hemodynamic tolerance.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Contatti e Sedi
Luoghi di studio
-
-
-
Bologna, Italia, 40057
- Azienda Ospedaliero-Universitaria "S. Orsola-Malpighi", Nephrology, Dialysis and Hypertension dpt.
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Dialysis vintage > 6 months
- Well functioning arterovenous fistula or central venous catheter
- thrice weekly HD treatment schedule
- Acute hypotensions in the last month before study start > 20% of sessions
Exclusion Criteria:
- Mental illness
- life expectancy < 6 months
- any profiling and/or biofeedback strategies routinely prescribed
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Hypotension-prone patients
The study group included all patients treated with standard HD prone to acute intradialytic hypotension.
|
Hemox optical sensor equips the dialysis monitors used during this trial.
It is able to measure continuously, on arterial blood line, oxygen saturation, hematocrit and blood volume reduction.
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
SO2 short-term variability predictive power
Lasso di tempo: 3 months
|
SO2 short term variability predictive power was assessed by means of common clinical tests indexes: sensitivity (number of sessions with effective hypotension correctly classified using SO2 standard deviation analysis) specificity (number of sessions without hypotension correctly classified using SO2 standard deviation analysis) |
3 months
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Central venous catheters subgroup analysis
Lasso di tempo: 3 months
|
This analysis was performed, according to the method described in the Primary Outcome section, only on the group of sessions in which a central catheter was used as vascular access.
|
3 months
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Antonio Santoro, MD, Azienda ospedaliera universitaria "S. Orsola-Malpighi", Bologna, Italy
Pubblicazioni e link utili
Pubblicazioni generali
- Santoro A, Mancini E, Basile C, Amoroso L, Di Giulio S, Usberti M, Colasanti G, Verzetti G, Rocco A, Imbasciati E, Panzetta G, Bolzani R, Grandi F, Polacchini M. Blood volume controlled hemodialysis in hypotension-prone patients: a randomized, multicenter controlled trial. Kidney Int. 2002 Sep;62(3):1034-45. doi: 10.1046/j.1523-1755.2002.00511.x.
- Locatelli F, Altieri P, Andrulli S, Bolasco P, Sau G, Pedrini LA, Basile C, David S, Feriani M, Montagna G, Di Iorio BR, Memoli B, Cravero R, Battaglia G, Zoccali C. Hemofiltration and hemodiafiltration reduce intradialytic hypotension in ESRD. J Am Soc Nephrol. 2010 Oct;21(10):1798-807. doi: 10.1681/ASN.2010030280. Epub 2010 Sep 2.
- Gueler F, Gwinner W, Schiborr C, Martin M, Klos A, Kirsch T, Fiebeler A, Haller H, Fliser D. Biocompatibility parameters of different dialysis membranes assessed during systemic inflammation. Blood Purif. 2005;23(3):196-202. doi: 10.1159/000083941. Epub 2005 Feb 10.
Studiare le date dei record
Studia le date principali
Inizio studio
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- CRC-MAL 01
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .