Physiological Behavior of Respiratory Maneuvers
Physiological Behavior of Respiratory Maneuvers Through Electrical Impedance Tomography and Optoelectronic Plethymography
Introduction: new methods of evaluation of respiratory function, such as electrical impedance tomography (EIT) and optoelectronic plethysmography (OEP), have been used to measure regional pulmonary ventilation and the variation of tricompartmental volumes of the thoracic cavity, respectively. Analysis of these instruments during maximal respiratory maneuvers with monitoring of esophageal pressure may probably provide additional information on the physiological behavior of the cardiorespiratory system during EIT and OEP maneuvers. Objectives: To describe the physiological behavior of maximal respiratory maneuvers through the electrical impedance tomography and optoelectronic plethysmography in healthy men.
METHODS: This is a cross-sectional study involving 10 healthy male volunteers. The development of the method will take place in 3 stages. The first step corresponds to the characterization of the inspiratory and expiratory curves in the respiratory cycle generated by the impedance variation (ΔZ), the mobility of the chest wall and the pulmonary volume curve during maximal respiratory maneuvers. 2nd stage: verification of the correlation between the variables Step 3: Estimate the dislocated blood volume of the lung through previous analyzes.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Descrizione dettagliata
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Contatti e Sedi
Luoghi di studio
-
-
PE - Pernambuco
-
Recife, PE - Pernambuco, Brasile, 50740300
- Universidade Federal de Pernambuco
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Will be included in the study male volunteers,
- BMI greater than or equal to 18.5 and less than 25 kg / m2, considered adequate or eutrophic (MS, 2011)
- Chest circumference between 44 and 55 cm if fitted to the electrical impedance tomography (EIT) strap size P or M;
- systolic blood pressure lower than 140 mmHg and greater than 100 mmHg
- diastolic blood pressure greater than 60 mmHg and lower than 90 mmHg (VI Brazilian Guidelines for Hypertension, 2010)
- without reports of cardiovascular or pulmonary diseases and symptoms Last month.
Exclusion Criteria:
- Volunteers who refuse to participate in the study will be excluded from the survey;
- Presence of cardiac dysfunction assessed by echocardiography;
- Altered pulmonary function by spirometry (PEREIRA et al, 2001) and manovacuometry according to predicted values for healthy individuals (PESSOA et al, 2014).
- Presence of tissue injury in the thorax;
- Dysautonomia that may indicate dysfunction of the autonomic nervous system (ANS), with following clinical manifestations: seizures; epilepsy; Anhydrosis and hyperhidrosis; Neurogenic bladder (CASTRO et al, 1992); (Stewart et al., 2004 and 2005)
- individuals who donated blood or had significant blood loss within 30 days prior to the start of the study (Navarro et al, 1997).
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: Altro
- Prospettive temporali: Trasversale
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Displacement of blood volume of the lung
Lasso di tempo: 09/03/2018
|
Volume displacement per unit time measured by electrical impedance tomography through the impedance variation in Ohm (Ω).
|
09/03/2018
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Variation of pulmonary electrical impedance
Lasso di tempo: 09/03/2018
|
Variation between the final and initial impedance measured by electrical impedance tomography through the impedance variation in Ohm (Ω).
|
09/03/2018
|
Altre misure di risultato
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Lung volume
Lasso di tempo: 09/03/2018
|
Measurement of the amount of air that the lungs may contain at various points in the respiratory cycle.
|
09/03/2018
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Cláudia Thais Pinto, Ms, UFPE
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 23031990
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .