Manipolatore uterino nella chirurgia del cancro dell'endometrio: studio Pro MUCEI (proMUCEI)
Uno studio prospettico sull'impatto del manipolatore uterino sull'esito oncologico nella chirurgia del cancro endometriale in fase iniziale: studio Pro MUCEI
The uterine manipulator is a device commonly used in minimally invasive hysterectomy surgery for endometrial cancer. However, without substantial evidence to support its use, surgeons are required to make decisions about its use based only on their personal choice and surgical experience.
A retrospective study demonstrated how uterine manipulator use in early-stage endometrial cancer (FIGO I-II) for minimally invasive surgery was associated with a worse oncologic outcome in patients with uterus-confined endometrial cancer (FIGO I-II) who underwent minimally invasive surgery.
The main objective of this study is to prospectively confirm the results obtained retrospectively, assessing the relapse rate in these patients related to the use or not of a uterine manipulator during the endometrial surgery. Secondary, the presence of risk factors that contraindicate the use of the uterine manipulator will also be evaluated.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
The primary treatment for early-stage endometrial cancer is surgery, performing a total hysterectomy and bilateral salpingo-oophorectomy with surgical staging if it is indicated.1 The National Comprehensive Cancer Network and European Society of Gynaecological Oncology Consensus recommend minimally invasive approaches (laparoscopic/robotic) in patients with disease limited to the uterus, according to evidence reported from randomized prospective studies (GOG-LAP2 trial).2 This approach leads to lower operative morbidity and a shorter hospital stay compared to open surgery, without compromising oncologic outcomes.3 The uterine manipulator is a device commonly used in minimally invasive gynecologic hysterectomy for benign disease. It is inserted vaginally through the cervical canal into the endometrial cavity. It facilitates the uterus mobilization during the surgery, generating tension on the main supporting elements of the uterus to improve surgical field exposure and provide a landmark for the colpotomy.4
With the introduction of minimally invasive approaches in gynecological oncology treatments, this uterine device has been utilized for endometrial and cervical cancers, with controversy regarding its influence on the spread of tumoral cells and the risk of recurrence. Recently, the LACC trial showed a worse than expected oncological outcome after a laparoscopic/robotic approach in early stage cervical cancer.5 One of the hypotheses generated was that the uterine manipulator might influence this worse prognosis.6 The retrospective European Succor study found the use of a manipulator was associated with a decrease in disease-free survival in cervical cancer in the minimally invasive group.7 Therefore, there are reasonable doubts about the uterine manipulator's safety in hysterectomy performed due to cancer.
In endometrial cancer, the presence of the uterine device in a cavity lined with neoplastic tissue leads to a potential tumor-manipulator interaction. Multiple mechanisms are potentially involved in this relationship but are poorly understood, however, the concept of uterus-confined disease is important to evaluate these interactions.8 Nonetheless, we have limited evidence from retrospectives studies about the uterine manipulator in endometrial cancer surgery, in which no impact of the uterine manipulator's use on oncological outcome has been found.9-12 To date, it remains a controversial conclusion that the theoretical tumor manipulation has no clear impact on oncological prognosis in endometrial cancer.
As is already known in other gynecological tumors (such as early-stage epithelial ovarian cancer or morcellation in unexpected uterine sarcoma), when the confined disease is exposed to the peritoneal cavity, the oncological outcome worsens.29 Therefore, the concept of organ-confined disease is an essential idea to understand our results. In early-stage endometrial cancer, the myometrium acts as a containment barrier, which may be iatrogenically injured by the uterine manipulator.
The MUCEI study by Padilla et al. suggests that the use of a uterine manipulator is associated with worse oncological outcomes in patients with uterus-confined endometrial cancer (FIGO I-II) at the time of surgery; it also presented a lower recurrence-free survival and lower overall survival, regardless of the type of manipulator with no differences in the pattern of recurrence.
The study observed a worse prognosis when the uterine manipulator was used in patients with the uterine-confined disease (FIGO I-II), not present in those patients with the no-confined disease (FIGO III) at the time of surgery. These results support the concept that the uterine manipulator might act in breaking the uterine-confined disease and worsen the oncological outcomes.
The different potential interferences may explain the alteration of the myometrial barrier by the uterine device. Therefore, two hypotheses are presented to explain this relationship between the uterine manipulator and endometrial cancer.
The first is the macroscopic injury hypothesis. During the insertion of any uterine manipulator (with or without balloon) and its use (especially in the atrophic uterus), the manipulator´s shank may weaken the myometrium, iatrogenically leading to uterine rupture and the opening of the tumor to the peritoneal cavity and surgical field.30,31 The uterine rupture is rarely reflected in surgical reports, and it has not been considered in previous analyses. Machida et al. showed a 0.4-1% perforation rate with a balloon manipulator,32 thus, other factors could be involved.
The second hypothesis is the microscopical pathway of dissemination. The uterine device generates a significant increase in pressure inside the endometrial cavity, generating global distension according to Pascal´s principle, which is additionally increased by the maintained push needed during uterine mobilization and colpotomy.33 This increased pressure might be involved in the improved ability of tumor cells to exceed the myometrial barrier, spreading outside the uterus cavity by a passive effect through the fallopian tubes and lymphovascular space.34
Methodology Prospective and non-randomized multicenter descriptive and analytical study in which the characteristics of the patients, the details associated with the surgery, and the oncological results will be studied depending on the use or not of the uterine manipulator.
The non-randomization is due to the fact that the procedure to be evaluated is surgeon-dependent, so the criteria for the use of the uterine manipulator or not will depend on the surgeon according to the protocol of his center. In other words, inclusion in the study does not modify the surgical practice in the patient.
Inclusion criteria include women with endometrial cancer diagnosed with stage I-II in a previous pre-surgical biopsy, the surgery has been performed and there are complete data on surgery, pathological anatomy, and follow-up.
Exclusion criteria include any patient with suspected disease beyond the uterus in the preoperative assessment or confirmed during surgical exploration. Cases without pathological confirmation of endometrial cancer in the final surgical specimen, or final histology of atypical hyperplasia/endometrial intraepithelial neoplasia will not be accepted.
Patients with open surgery, conversion to laparotomy, or vaginal hysterectomy alone will also be excluded.
The surgical variables collected will be: use of uterine manipulator (the type of uterine manipulator and classification of subtypes with or without intrauterine balloon), sealing of the fallopian tubes, surgical staging, intraoperative complications, surgical time and hospital stay. Collection of postoperative complications by Clavien-Dindo Classification. The final histological data of the surgery will be collected according to the type and grade of the tumor according to the WHO classification, the invasion of the myometrium, the presence of invasion of the lymphovascular space, sentinel (+/- ultrastaging) and the number of pelvic lymph nodes. and para-aortic. The Bokhman dual classification of endometrial cancer will be used. and tumors were classified by FIGO staging. Finally, data on adjuvant treatment (vaginal brachytherapy, external beam radiation (ERBT), and chemotherapy scheme), follow-up time, relapse time, and type and pattern of relapse.
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Contatti e Sedi
Luoghi di studio
-
-
Valencia
-
Valencia, Valencia, Spagna, 46026
- Hospital universitario y politécnico La Fe
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Bambino
- Adulto
- Adulto più anziano
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
All patients older than 18 years undergoing surgery in an apparently early stage of endometrial cancer proposed by FIGO: total hysterectomy with double adnexectomy and evaluation of the lymph node status following recommendations for surgical staging by FIGO. Follow-up prospectively, gathering the necessary information already described in the previous sections.
Descrizione
Inclusion Criteria:
- - Women with endometrial cancer diagnosed with stage I-II.
- - Previous pre-surgical biopsy with a diagnosis of endometrial cancer.
- - The surgery has been performed and there are complete data on surgery, pathological anatomy, and follow-up of at least 2 years.
Exclusion Criteria:
- Any patient with suspected disease beyond the uterus in the preoperative assessment or confirmed during surgical exploration. Cases without pathological confirmation of endometrial cancer in the final surgical specimen or final histology of atypical hyperplasia/endometrial intraepithelial neoplasia will not be accepted.
Patients with open surgery, conversion to laparotomy, or vaginal hysterectomy alone will also be excluded.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: CASE_CONTROL
- Prospettive temporali: PROSPECTIVE
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
uterine manipulator cohort
Patients with early-stage endometrial cancer who have performed a hysterectomy with a uterine manipulator to mobilize the uterus during the surgery. |
The uterine manipulator is a device commonly used in minimally invasive hysterectomy surgery for endometrial cancer. However, without substantial evidence to support its use, surgeons are required to make decisions about its use based only on their personal choice and surgical experience. . It is inserted vaginally through the cervical canal into the endometrial cavity. The uterine manipulator facilitates the uterus mobilization during the surgery, generating tension on the main supporting elements of the uterus to improve surgical field exposure and provide a landmark for the colpotomy. |
|
no uterine manipulator cohort
Patients with early-stage endometrial cancer who have performed a hysterectomy without a uterine manipulator to mobilize the uterus during the surgery. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Relapse rate
Lasso di tempo: 2 years
|
To prospectively evaluate the relapse rate in patients undergoing surgery for apparently early-stage endometrial cancer (FIGO I-II) with minimally invasive surgery with or without the use of a uterine manipulator. |
2 years
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Other oncological outcomes
Lasso di tempo: 3 years
|
Assess oncological variables: disease-free period and overall survival. |
3 years
|
|
Relapse pattern
Lasso di tempo: 3 years
|
Identify relapse pattern: local, locoregional and distant. |
3 years
|
|
Surgical specimen variables
Lasso di tempo: 1 year
|
Histology variables in surgical specimen: relationship between lymphovascular invasion and uterine manipulator. |
1 year
|
|
Treatment data
Lasso di tempo: 1 year
|
Collect and analyze the characteristics of the surgical procedure and the adjuvant treatment received. |
1 year
|
|
Pathology data
Lasso di tempo: 1 year
|
Collect and analyze the characteristics of the histological data and the adjuvant treatment received. |
1 year
|
|
Recurrence treatment
Lasso di tempo: 3 years
|
Recurrence treatment |
3 years
|
|
complications
Lasso di tempo: 1 year
|
Intraoperative and postoperative complications rate |
1 year
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Pablo Padilla iserte, MD, PhD, Hospital Universitario La Fe
Pubblicazioni e link utili
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- pro MUCEI (507-21/07/21)
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .