Valutazione dell'uso del monitor continuo del glucosio nei pazienti di cure primarie scarsamente serviti
Continuous glucose monitoring (CGM) has demonstrated improved outcomes in both type 1 and type 2 diabetes populations in comparison to traditional methods; however, these devices have not been well studied in underserved adult patients (e.g., low-income, uninsured) who may face additional barriers to monitoring. Furthermore, there is limited data exploring long-term (3- to 6- month) health care team-based management of these devices in the primary care setting. The purpose of this study is to further understand the benefits and barriers associated with CGM use in underserved populations with type 2 diabetes and improve their overall diabetes care.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Continuous glucose monitoring (CGM) has demonstrated improved outcomes in both type 1 and type 2 diabetes populations in comparison to traditional methods; however, these devices have not been well studied in underserved adult patients (e.g., low-income, uninsured) who may face additional barriers to monitoring. Furthermore, there is limited data exploring long-term (3- to 6- month) health care team-based management of these devices in the primary care setting. This study will evaluate the perceived and experienced benefits and barriers of continuous glucose monitor (CGM) and traditional glucometer use and identify diabetes related outcomes associated with CGM use relative to usual care with self-monitoring of blood glucose (SMBG) in an underserved population.
Eligible adult (>=19 years of age) patients at participating clinics with type 2 diabetes, A1c >=9%, and concomitant insulin therapy and/or using two or more diabetes medications will be randomly enrolled to one of two groups: Freestyle Libre 2 CGM or traditional glucometer. Pre- and post-surveys will be used to evaluate perceived and experienced benefits and barriers to CGM use and diabetes-related outcomes will be compared between the groups using face-to-face, telephonic, and/or digital avenues. The latter aim will replicate current processes of team-based diabetes care which is blood glucose management from a pharmacist under collaborative practice with the primary care physician. Follow-up will also replicate these clinic processes throughout the 6-month period, including telephone calls and monthly in-clinic visits.
Tipo di studio
Tipo di studio
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Nebraska
-
Omaha, Nebraska, Stati Uniti, 68198-7400D
- Nebraska Medicine
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Type 2 diabetes
- A1c >9% at recruitment
- On/initiating insulin or on two or more diabetes medications
Exclusion Criteria:
- Current use of an insulin pump
- On dialysis
- Pregnant
- Implanted medical device (e.g., pace-maker, defibrillator)
- Intellectual or physical disabilities that may interfere with ability to properly use the Continuous Glucose Monitor (CGM)
- Able to read English
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Non randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Continuous Glucose Monitoring
Participants will use a Freestyle Libre 2 monitoring device for 6 months to track blood glucose levels. |
A Freestyle Libre 2 continuous glucose monitor (CGM) will be provided in the experimental arm of this study for 6 months.
Altri nomi:
|
|
Comparatore attivo: Traditional Glucometer Arm
Participants will use a traditional glucose monitoring device (glucometer) to self-monitor their blood glucose for 6 months to track blood glucose levels. |
A traditional glucometer device will be assigned in the active comparitor arm of this study for 6 months.
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Glycemic Control (Hemoglobin A1c)
Lasso di tempo: Baseline, 3 months, and 6 months.
|
Glycemic control will be assessed by measuring hemoglobin A1c at baseline, 3 months, and 6 months. Values will be evaluated as a continuous variable and categorized as <7.0% vs >7.0% to <9.0% and >9.0%. Comparisons of the proportions of participants achieving a minimum of 1 point drop in hemoglobin A1c will be made between study arms. |
Baseline, 3 months, and 6 months.
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Hypoglycemia
Lasso di tempo: 6 months
|
Continuous glucose monitor (CGM) and glucometer blood glucose data will be evaluated to determine number and percentage of hypoglycemic readings (i.e., <70 mg/dL). For CGM data, % time within target range, % time below specific thresholds for hypoglycemia) will be captured and described. |
6 months
|
|
Hyperglycemia
Lasso di tempo: 6 months
|
Continuous glucose monitor (CGM) and glucometer blood glucose data will be evaluated to determine percentage of hyperglycemic values (i.e., >180 mg/dl) experienced. For CGM data, % time within target range, % time below specific thresholds for hypoglycemia) will be captured and described. |
6 months
|
|
Blood Glucose Capture Rate
Lasso di tempo: 6 months
|
Number of days without any blood glucose recordings will be captured as a percentage over the study period. |
6 months
|
|
Perceived or Experienced Benefits and Barriers to Device Use
Lasso di tempo: Baseline and 6 months
|
A pre- and post-survey will be provided to all participants to qualitatively identify benefits and barriers to access and use of their assigned device and willingness to continue CGM use (follow-up survey). |
Baseline and 6 months
|
Collaboratori e investigatori
Sponsor
Sponsor
Collaboratori
Collaboratori
Investigatori
Investigatori
- Investigatore principale: Drew C Prescott, PharmD, University of Nebraska
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
- Malattie del sistema endocrino
- Malattie metaboliche
- Disturbi del metabolismo del glucosio
- Diabete mellito
- Malattie nutrizionali e metaboliche
- Diabete mellito, tipo 2
- Tecniche investigative
- Terapie
- Tecniche di laboratorio clinico
- Tecniche e procedure diagnostiche
- Diagnosi
- Analisi chimica del sangue
- Test di chimica clinica
- Tecniche diagnostiche, endocrino
- Monitoraggio, fisiologico
- Autotest
- Automedicazione
- Auto-monitoraggio della glicemia
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 0314-22-FB
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .