Valutazione dell'andatura tramite applicazione telefonica
Validità e affidabilità di un'applicazione smartphone per la valutazione dell'andatura
The evaluation of human gait is a crucial component of the clinical assessment and decision-making process. The gold standard in gait analysis is computerized gait analysis, which allows for three-dimensional digital data acquisition through computers (3D Computerized Gait Analysis). However, this technology is not readily accessible in routine analyses, as it proves to be a time-consuming and expensive endeavor in terms of infrastructure and human resources. The utilization of smartphones in clinical applications is on the rise, facilitated by the increasing accessibility of low-cost or free "applications," thereby addressing the limitations associated with traditional gait analysis methods. The Gait-Analyzer application is among the mentioned applications. However, in the literature, no evidence has been found regarding the validity and reliability of Gait-Analyzer application compared to the gold standard 3D computerized gait analysis systems within the context of gait analyses.
The aim of this study is to comparatively examine the effectiveness of the Gait-Analyzer smartphone application with established 3D Computerized Gait Analysis systems, which have proven validity and reliability in gait analyses. Through this research, the study intends to elucidate the validity and reliability of spatiotemporal parameters of walking within the Gait-Analyzer smartphone application.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Voluntary healthy participants will be included in the study. Signed voluntary consent will be obtained from participants. Participants will be divided into two groups. 3D Computerized Gait Analysis will be applied to one group first, and Gait-Analyzer smarthphone application will be applied to the other group first.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Contatti e Sedi
Luoghi di studio
-
-
-
Istanbul, Turchia (Türkiye), 34752
- Acibadem Mehmet Ali Aydinlar University
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Volunteers willing to participate in the study and who meet the inclusion criteria of being healthy
Descrizione
Inclusion Criteria:
- Age between 18 and 26 years.
- Body Mass Index (BMI) within normal limits (18.5-24.9 kg/m2)
Exclusion Criteria:
- Presence of lower extremity rotational problems (such as high femoral anteversion, internal tibial torsion, metatarsus adductus).
- History of Botulinum Toxin Type A (BoNT-A) application or surgery within the last 6 months.
- History of lower extremity injury within the last 6 months.
- Leg length discrepancy.
- Presence of third-degree pes planus.
- Any neurological, rheumatic, musculoskeletal, metabolic, or connective tissue diseases.
- History of pain, deformity, or surgery related to the vertebral column and upper extremities.
- Presence of cognitive, mental, and/or severe psychiatric disorders
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: CASE_ONLY
- Prospettive temporali: PROSPECTIVE
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
3D Computerized Gait Analysis
The gait analysis will be conducted through 3D computerized gait analysis. |
It will be carried out on a 10-meter flat surface, with the participant walking at normal walking speed. |
|
Gait-Analyzer
The gait analysis will be performed using a smartphone application called Gait-Analyzer. |
It will be carried out on a 10-meter flat surface, with the participant walking at normal walking speed. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Three-Dimensional Computerized Gait Analysis
Lasso di tempo: change from baseline at first week
|
Reflective markers are placed on specific anatomical points to record varying joint angles throughout the walking cycle. Patients walk a distance of 9-10 meters, capturing records of their walking patterns and speed in everyday life, either barefoot or using assistive walking devices. |
change from baseline at first week
|
|
Gait-Analyzer
Lasso di tempo: change from baseline at first week
|
Gait-Analyzer is a mobile application for smartphones capable of real-time analysis of walking parameters. Using a smartphone with an Android processor and the "Gait Analyzer" application, directly attached to the participants' lumbar spine (nearest to L5) with a waist belt, participants will be instructed to complete 6 laps (12 forward and backward walks) on a 10-meter walking path. |
change from baseline at first week
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Ayşenur Erekdağ, MSc, Bezmialem Vakif University
Pubblicazioni e link utili
Pubblicazioni generali
- Stuberg WA, Colerick VL, Blanke DJ, Bruce W. Comparison of a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography. Phys Ther. 1988 Aug;68(8):1221-5.
- Norris BS, Olson SL. Concurrent validity and reliability of two-dimensional video analysis of hip and knee joint motion during mechanical lifting. Physiother Theory Pract. 2011 Oct;27(7):521-30. doi: 10.3109/09593985.2010.533745. Epub 2011 May 15.
- Finkbiner MJ, Gaina KM, McRandall MC, Wolf MM, Pardo VM, Reid K, Adams B, Galen SS. Video Movement Analysis Using Smartphones (ViMAS): A Pilot Study. J Vis Exp. 2017 Mar 14;(121):54659. doi: 10.3791/54659.
- Kelly M, Jones P, Wuebbles R, Lugade V, Cipriani D, Murray NG. A novel smartphone application is reliable for repeat administration and comparable to the Tekscan Strideway for spatiotemporal gait. Measurement (Lond). 2022 Mar 31;192:110882. doi: 10.1016/j.measurement.2022.110882. Epub 2022 Feb 11.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 93402A830
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .