Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Lo studio PARS: studio sul servizio respiratorio avanzato pediatrico: uno studio osservazionale di fattibilità diagnostica (PARS)

9 novembre 2026 aggiornato da: Ross Langley, NHS Greater Clyde and Glasgow

Diagnostic investigations in paediatric respiratory and sleep medicine are often challenging due to patient size (due to prematurity), tolerability, and compliance with "gold standard equipment". Children with sensory/behavioural issues, at increased risk of sleep disordered breathing (SDB), often find tolerating standard diagnostic equipment difficult. There is a need to develop non-invasive, wireless, devices designed for the paediatric population. Devices must address health in-equalities as high-risk children, with low birth weights, genetic syndromes, or complex neuro-disabilities, are often unable to undergo current investigations, particularly in sleep medicine. Prompt and accurate diagnosis of SDB is important to facilitate early intervention and improve outcomes

Infants in the neonatal period can have immature breathing control which manifests as excessive central breathing pauses, apnoea's, whilst asleep requiring oxygen therapy. There is also a risk to newborn term infants of sudden unexpected neonatal collapse, even in "low risk" babies. Diagnosis of breathing issues in babies can be challenging since babies are often too small for standard monitoring equipment. Effective monitoring and appropriate treatment of apnoea's has been shown to improve prognosis in terms of 5-year mortality and neurodevelopmental outcomes.

Children with epilepsy are at risk of epileptic apnoea during a seizure (ictal) or post-ictal apnoea following an epileptic seizure. Epileptic and post-ictal apnoea have been implicated as causes of sudden unexpected death in epilepsy (SUDEP). Epilepsy affects approx. 50 million people worldwide. The risk of SUDEP varies in different underlying causes of epilepsy but is estimated to be the cause of 1.2 deaths for every 1,000 children with epilepsy each year.

This observational study is part of a phased clinical program of research that aims to validate a small wearable biosensor developed by PneumoWave Ltd in a paediatric clinical setting with the overall primary endpoints of monitoring and assessing respiratory pattern as an aid to sleep diagnostics, and as a device to monitor apnoea in neonatal patients and children with epilepsy at risk of SUDEP.

Panoramica dello studio

Stato

Reclutamento

Condizioni

Intervento / Trattamento

Descrizione dettagliata

Sleep diagnostics

The investigation of sleep disordered breathing (SDB) in children can be challenging given the requirement to apply sensors/bands that measure physiological changes as part of a cardiorespiratory sleep study (CR-poly). Children with sensory/behavioural issues, who have an increased risk of SDB, often find tolerability of standard diagnostic equipment difficult. Similarly, the usefulness is limited in low weight infants. Thus, there is a need to investigate novel devices which may provide sleep diagnostic information when a CR-poly may be inappropriate or challenging. A wearable respiratory rate (RR)/effort sensor can provide continuous remote monitoring of patients and may identify abnormal breathing patterns associated with SDB.

Central apnoea and abnormal breathing patterns in neonatal patients

Babies born prematurely can often have apnoea of prematurity requiring caffeine therapy. Similarly, term (or term corrected) infants can have immature breathing control which manifests as excessive central breathing pauses whilst asleep requiring oxygen therapy. There is also a risk to newborn term infants of sudden unexpected collapse, even in "low risk" babies. Diagnosis of breathing issues in babies can be challenging since babies are often too small for standard CR-poly equipment. We aim to use the Pneumowave sensor alongside other diagnostic equipment to assess the feasibility of using this novel sensor to aid diagnosis in the post-natal period and pre-discharge from neonatal unit. Currently, newborn infants receive no standard respiratory monitoring following delivery. We aim to use the Pneumowave sensor as an indicator of altered respiratory patterns in this patient group.

Apnoeas in patients attending the epilepsy monitoring unit

Children with epilepsy are at risk of epileptic apnoea during a seizure (ictal) or post-ictal apnoea following an epileptic seizure. Epileptic and post-ictal apnoea have been implicated as causes of sudden unexpected death in epilepsy (SUDEP). Epilepsy affects approx. 50 million people worldwide. The risk of SUDEP varies in different underlying causes of epilepsy but is estimated to be the cause of 1.2 deaths for every 1,000 children with epilepsy each year. We aim to use the Pneumowave sensor alongside other diagnostic equipment to assess the feasibility of using this novel sensor to detect ictal and post-ictal apnoea in children attending inpatient EEG video-telemetry monitoring. There are no clinical or commercially-available reliable sensors to detect epileptic apnoea. We aim to use the Pneumowave sensor as an indicator of altered respiratory patterns in this patient group and assess whether data can be reliably collected in the context of an epileptic seizure.

PneumoWave Ltd Device

PneumoWave Ltd is developing a small, chest-worn, ambulatory biosensor ("Pneumowave") to detect changes in a range of respiratory metrics. This physical monitor is linked wirelessly via Bluetooth to a central monitoring systems in the form of a mobile platform app (running on a smartphone or tablet). Real-time data analysis, event detection and alert response management algorithms will eventually be are located in the hub, mobile app - they are currently in the cloud depending on the device configuration.

The proposed technology, Pneumowave device, will be used in the diagnosis, treatment and monitoring of illness, and therefore must be regulated as a Class 2 Medical Device in accordance with the regulatory framework in each country of use. To achieve this, PneumoWave Ltd first intends to develop a device capable of detecting adverse respiratory events in the hospital setting where immediate attendance to alerts is available. Further technical development will be required prior to the submission for regulatory approval of a device that is suitable for use in the community where there may be a longer time before a response is activated.

This hospital study aims to compare the PneumoWave Ltd monitoring system with the current clinical standard for such monitoring in a range of hospital-based clinical services.

The studies will observe three distinct patient groups:

Group 1: Patients attending for an overnight CR-poly Group 2: Patients who are at risk of apnoea in the neonatal unit Group 3: Patients who are at risk of apnoea in the epilpsey monitoring unti

Tipo di studio

Osservativo

Iscrizione (Stimato)

225

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Luoghi di studio

    • Glasgow
      • Glasgow, Glasgow, Regno Unito, G51 4TF
        • Attivo, non reclutante
        • Royal Hospital for Children, Glasgow
    • Glasgow City
      • Glasgow, Glasgow City, Regno Unito, G51 4TF

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 1 minuto a 16 anni (Bambino)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

The target number of participants in this study is 225. 75 patients who fit group 1 characteristics, 75 patients who fit group 2 characteristics and 75 patients who fit group 3 characteristics.

Descrizione

Inclusion Criteria:

Group 1 - CR-poly group

  • Patient undergoing overnight CR-poly
  • Age birth to >=16 years
  • Are willing and able to give informed assent/consent or have available next of Kin to provide informed consent on the participant's behalf
  • Able (in the Investigators opinion) to comply with all study requirements
  • Can speak and read English

Group 2 - Apnoea group

  • Inpatient in neonatal unit
  • Age birth (from 30 weeks gestational age) to term corrected
  • Parents willing and able to give informed consent
  • Able (in the Investigators opinion) to comply with all study requirements
  • Can speak and read English

Group 3- VT Group attending epilepsy monitoirng unit

  • Inpatient receiving video-telemetry epilepsy monitoring unit
  • Age birth to <16 years
  • Parents willing and able to give informed consent
  • Able (in the Investigators opinion) and willing to comply with all study requirements
  • Can speak and read English

Exclusion Criteria:

Group 1 - CR-poly group

  • Unable to provide consent and no next of kin to provide consent on participants behalf
  • Treating clinician deems patient inappropriate to be included in study

Group 2 - Apnoea group

  • No next of kin to provide consent on participants behalf
  • Treating clinician deems patient inappropriate to be included in study

Group 3- VT Group attending epilepsy monitoirng unit

  • Unable to provide consent and no next of kin to provide consent on participants behalf
  • Treating clinician deems patient inappropriate to be included in study

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Modelli osservazionali: COHORT
  • Prospettive temporali: PROSPECTIVE

Coorti e interventi

Gruppo / Coorte
Intervento / Trattamento
Patient attending for overnight cardiorespiratory polysomnography sleep study

Any patient attending the Royal Hospital for Children, Glasgow sleep laboratory for overnight cardiorespiratory polysomnography for evaluation of sleep disordered breathing. Pneumowave device will collect data from patients alongside standard clinical monitoring.

Pneumowave biosensor(s) will be be used to collect data from chest +/- abdominal movement and compared to standard clinical monitoring data

Patients in the neonatal unit, Royal Hospital for Children, Glasgow, at risk of central apnoea

Any patient currently in the Queen Elizabeth University Hospital campus neonatal unit at risk of central apnoea receiving standard care (this may include mechanically ventilated patients). Pneumowave device will collect data from patients alongside standard clinical monitoring.

Pneumowave biosensor(s) will be be used to collect data from chest +/- abdominal movement and compared to standard clinical monitoring data

Patients attending the epilepsy monitoirng unit for Video Telemetry

Any patient attending the Royal Hospital for Children, Glasgow Epilepsy Monitoring Unit for inpatient video-telemetry at risk of apnoea during and following seizures

Pneumowave biosensor(s) will be be used to collect data from chest +/- abdominal movement and compared to standard clinical monitoring data

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Assess the feasibility of collecting respiratory waveform data using Pneumowave device in patients who have (1) attended the sleep laboratory for CR- polysomnography and (2) are inpatient in neonatal unit
Lasso di tempo: 2 years

1) Length of time device in situ on patient 2) Number of times device removed by patient / other 3) Ability of device to collect data while in situ

2 years

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Collate respiratory data in patients who have attended the sleep laboratory for CR- poly or inpatient in neonatal unit. Respiratory data will observe: (1) Normal respiratory effort (2) Response to treatments
Lasso di tempo: 2 years

(1) Observation of waveform data from Pneumowave device and compare to: normal care vital signs and continuous monitoring vital signs extracted from patient monitors. (2) Compare Pneumowave respiratory wave patterns to clinical events: normal respiratory patterns and clinical deterioration

2 years
Collate waveform and motion artefact data in patients who have attended overnight CR-polysomnography
Lasso di tempo: 2 years

Compare respiratory waveform patterns and motion artefact data to: banded sleep diagnostic information

2 years
Collate waveform and motion artefact data in neonatal patients at risk of central apnoea
Lasso di tempo: 2 years

(1) Observation of waveform data from Pneumowave device and compare to: normal care vital signs, continuous monitoring vital signs extracted from patient monitors (2) Compare Pneumowave respiratory wave patterns to clinical events: normal respiratory patterns, clinical deterioration ,Interventions in neonatal unit

2 years
Assess the useability of Pneumowave in the opinion of the clinician, nurse and patient
Lasso di tempo: 2 years

Interview of the stakeholders on the useability of the device: Clinician, Nurse, Patient (if able to)

2 years

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Collaboratori

Investigatori

  • Investigatore principale: Ross J Langley, MBChB BSc PhD MRCPCH, NHS Greater Glasgow and Clyde

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Pubblicazioni generali

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

1 marzo 2024

Completamento primario (Stimato)

1 dicembre 2027

Completamento dello studio (Stimato)

1 dicembre 2027

Date di iscrizione allo studio

Primo inviato

26 febbraio 2024

Primo inviato che soddisfa i criteri di controllo qualità

26 febbraio 2024

Primo Inserito (Effettivo)

5 marzo 2024

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

13 novembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

9 novembre 2026

Ultimo verificato

1 novembre 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • INGN22RM471P
  • 10072600 (Altro numero di sovvenzione/finanziamento: PneumoWave Ltd & Innovate UK)

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

SÌ

Descrizione del piano IPD

IPD will be shared with other collaborators on the grant. No identifiable data will be shared.

Periodo di condivisione IPD

IPD will be available by December 2025

Criteri di accesso alla condivisione IPD

PneumoWave will be able to access IPD, no patient identifiable information will be shared with PneumoWave. IPD from this study will be included in a final report, presented at paediatric meetings and published in peer reviewed paediatric journals.

Tipo di informazioni di supporto alla condivisione IPD

  • STUDIO_PROTOCOLLO
  • ICF
  • RSI

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .