Risultati protesici e prestazioni cliniche delle corone in zirconio supportate da impianti
Risultati protesici e prestazioni cliniche di due tipi di corone avvitate monolitiche a base di zirconio. Uno studio clinico randomizzato
To compare biological, technical, radiographic, and patient-reported outcomes of two types of monolithic zirconia crowns screw-retained to implant.
To assess whether the new form of multilayered zirconia crowns will show similar survival and success rate to conventional monolithic Zirconia screw-retained to implants in molar and premolar regions.
First Null Hypothesis: Multilayered monolithic zirconia crowns would have similar survival, success rate compared to conventional monolithic zirconia implant supported crowns.
Second Null hypothesis: There would be no difference in clinical and patients related outcomes between multilayered and conventional monolithic zirconia implant supported crowns.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Study design:
A short-randomized controlled trial study, the (PICO) study design: population will be patients from Jordan University Hospital with implants planned for single screw-retained zirconia crowns in the posterior site (premolar or molar), intervention will be the multilayer monolithic screw-retained zirconia crowns over implants, the comparator is the conventional monolithic zirconia crowns over implants, and the main outcomes will be the prosthetic/technical outcomes, survival and success rates in addition to radiographic, patient-reported outcomes, and biological parameters.
Methodology The patients who fulfilled the inclusion/exclusion criteria and entered the study will have a fully digital workflow starting from data acquisition using an intraoral scanner (3Shape TRIOS® 5) , Ti-base abutment design and CAD/CAM milling of the two types of monolithic zirconia blanks (IPS e.max® ZirCAD Prime and IPS e.max® ZirCAD LT).
The fabricated zirconia crowns in both groups will have the same treatment and will be cemented to the Ti-base abutment according to the (APC) concept; alumina airborne-particle abrasion 50-μm at 1 bar for 15-20 seconds, intaglio surface primed using MDP for 60 seconds and air blown for 5 seconds, and finally cemented to the abutment by phosphate monomer resin cement PANAVIA™ V5(Blatz-Alvarez-Compendium-APC-2016, n.d.).
On the other hand, the Ti-base abutment: height will be standardized at 4mm, and the base abutment surface will have blasting with alumina particles of 50 μm at 2-bar pressure for 15-20 seconds at a 10-mm step-over distance at an angle of 45 degrees.
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Amman, Giordania, 11181
- The university ofJordan
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Partially edentulous area with suitable restorative space more than 5.5 mm
- At least 18 years of age
- Opposing natural teeth or fixed restorations supported by teeth or implants.
- Generally good health (ASA I, ASA II)
- Participant complies with good oral hygiene practices (BOP and PI less than 20%)
- Healthy integrated implant/s without signs of periimplantitis in the posterior site planned for single tooth replacement (in premolar or molar areas)
- Patients received bone-level implants, RC Straumann Implants.
Exclusion Criteria:
- Inability to provide consent.
- Temporomandibular disorders
- Smoking of more than 10 cigarettes per day
- Untreated caries or periodontal disease of remaining dentition
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Triplicare
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Graded monolithic Zirconia Crowns
3Y-TZP/5Y-TZP zirconia crown |
monolithic implant supported crown |
|
Comparatore attivo: Conventional monolithic Zirconia Crowns
3Y-TZP zirconia crowns |
monolithic implant supported crown |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Technical & Biological Outcomes
Lasso di tempo: Baseline, 6 months, 12 months
|
The abutments and restoration will be evaluated clinically by two blinded investigators, according to the modified United States Public Health Service (USPHS) criteria USPHS criteria involve four Scales: Alpha, Bravo, Charlie, Delta The criteria of evaluation include: Restoration fracture, Abutment Fracture, Loosening of the restoration, Screw-access hole restoration, Occlusal Wear, Anatomical Form, Color match, Proximal contact, Occlusal Contact, Marginal Fit, Periodontal parameters. |
Baseline, 6 months, 12 months
|
|
Survival and Success rate
Lasso di tempo: 6 months, 12 months
|
All patients will be evaluated for success and survival of restorations at 6 months and 1 year after placement of the restorations (Follow-ups). The success rate is defined as the number of restorations that did not change over time. The survival rate is defined as the number of restorations that did not require replacement. |
6 months, 12 months
|
|
Patient reported outcomes
Lasso di tempo: 6 months, 12 months
|
Patient satisfaction in terms of the shape and shade of the crown, their ability to chew (function) and floss (proximal contact) and their overall satisfaction with the restoration provided will be assessed by a questionnaire based on a five-grade ordinal category scale (extremely satisfied, satisfied, neutral, dissatisfied and extremely dissatisfied). Each patient was asked to fill out the questionnaire themselves to ensure as little bias as possible. |
6 months, 12 months
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Susan Hattar, Professor, University of Jordan
Pubblicazioni e link utili
Pubblicazioni generali
- Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res. 2012 Oct;23 Suppl 6:2-21. doi: 10.1111/j.1600-0501.2012.02547.x.
- Le M, Dirawi W, Papia E, Larsson C. Clinical Outcome of Three Different Types of Posterior All-Ceramic Crowns. A 3-Year Follow-up of a Multicenter, Randomized, Controlled Clinical Trial. Int J Prosthodont. 2023 Nov 1;36(5):546-553. doi: 10.11607/ijp.8016.
- Hosseini M, Worsaae N, Gotfredsen K. A 5-year randomized controlled trial comparing zirconia-based versus metal-based implant-supported single-tooth restorations in the premolar region. Clin Oral Implants Res. 2022 Aug;33(8):792-803. doi: 10.1111/clr.13960. Epub 2022 Jun 11.
- Zhang CN, Zhu Y, Zhang YJ, Jiang YH. Clinical esthetic comparison between monolithic high-translucency multilayer zirconia and traditional veneered zirconia for single implant restoration in maxillary esthetic areas: Prosthetic and patient-centered outcomes. J Dent Sci. 2022 Jul;17(3):1151-1159. doi: 10.1016/j.jds.2022.01.012. Epub 2022 Feb 5.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- Susan Hattar
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .