Fluido somministrato secondo PVI rispetto alla gestione dei fluidi negli interventi laparoscopici di Trendelenburg
Confronto tra i fluidi somministrati secondo l'indice di variabilità pletismografica e la gestione ideale dei fluidi negli interventi laparoscopici di Trendelenburg
Investigating the ideal fluid management in Trendelenburg positions during lower abdominal laparoscopic surgeries in gynecological oncology and surgical oncology patients
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Laparoscopic lower abdominal surgeries include carbon dioxide (CO2) insufflation and an advanced Trendelenburg position with the head down. Increased intra-abdominal pressure can reduce cardiac index and cause changes in total body fluid balance. However, the head down Trendelenburg position increases intracranial pressure and preload. According to traditional fluid management, intraoperative fluid deficit is calculated according to the 4-2-1 rule, by summing up hourly basal fasting level, intraoperative losses due to degree of tissue trauma (1-2mlt/kg/h in minor surgeries, 2-4mlt/kg/h in medium surgeries, 4-8mlt/kg/h in major surgeries), blood losses, urine and losses from nasogastric tube.
Preservation of intravascular volume and thus provision of hemodynamic stability are among the factors affecting postoperative morbidity and mortality. Some studies have shown that standard fluid therapy is more than necessary. Current guidelines recommend more restrictive approaches by ensuring hemodynamic stability. Masimo, which we also use routinely in our clinic, is a device designed for continuous noninvasive monitoring of arterial hemoglobin functional oxygen saturation (SpO2), pulse rate (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values. In our study, in the individualization of the recommended target-oriented restrictive fluid therapy in major surgeries, by comparing the calculated fluid amount with traditional fluid management with PVI values (PVI is evaluated between 0-100.
Normavolemia 15-25 low fluid responsiveness <15 high fluid responsiveness >25) and when the patient's massimo pvi score is >25, 300cc bolus fluid will be administered and fluid will be loaded at an average speed and the PVI value will be reduced below 25. When the patient's massimo PVI value is below 25, restrictive fluid therapy will be followed.(A crystalloid fluid infusion of 2 mL/kg was administered to the patients.)
The aim was to investigate the ideal fluid management in Trendelenburg positions in lower abdominal laparoscopic surgeries performed in gynecological oncology and surgical oncology patients.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Ankara, Turchia (Türkiye), 06010
- Ankara Etlik City Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
İnclusion Criteria:
- between the ages of 18-80
- patients with ASA score II III
- Laparoscopic lower abdominal surgery (patients undergoing gynecological oncology and surgical oncology surgery)
Exclusion Criteria:
- ASA score IV
- Patients with heart failure and chronic kidney disease
- Patients who did not agree to participate in the study
- Cases that started laparoscopically and converted to laparotomy
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Altro
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Doppio
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Massimo group
The patient is not given fluids until the Massimo PVI score is >25, a 300 cc fluid bolus is given when the PVI is above 25, and fluid loading is performed at an average rate until the PVI falls below 25. If the patient's Massimo PVI is below 25, restrictive fluid therapy is applied. |
masimo is a device for the continuous noninvasive measurement of arterial hemoglobin functional oxygen saturation (SpO2), pulse rate (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index). |
|
Comparatore attivo: standart group
intraoperative fluid deficit is calculated according to the 4-2-1 rule by summing up the hourly basal fasting level, intraoperative losses depending on the degree of tissue trauma (1-2mlt/kg/h in small-sized surgeries, 2-4mlt/kg/h in medium-sized surgeries, 4-8mlt/kg/h in large-sized surgeries), blood losses, urine and losses from the nasogastric tube. Fluid is given in this way. |
intraoperative fluid deficit is calculated according to the 4-2-1 rule by summing up the hourly basal fasting level, intraoperative losses depending on the degree of tissue trauma (1-2mlt/kg/h in small-sized surgeries, 2-4mlt/kg/h in medium-sized surgeries, 4-8mlt/kg/h in large-sized surgeries), blood losses, urine and losses from the nasogastric tube. Fluid is given in this way. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
PI (perfusion index)
Lasso di tempo: ten minutes results before induction
|
arterial hemoglobin functional oxygen saturation % (SpO2), pulse rate (PR) beats per minute, pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
ten minutes results before induction
|
|
PVI (pleth variability index)
Lasso di tempo: ten minutes results before induction
|
arterial hemoglobin functional oxygen saturation % (SpO2, pulse rate (PR) beats per minute, pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
ten minutes results before induction
|
|
SPO2 (hemoglobin functional oxygen saturation)
Lasso di tempo: ten minutes results before induction
|
arterial hemoglobin functional oxygen saturation % (SpO2), pulse rate (PR) beats per minute, pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
ten minutes results before induction
|
|
PR (pulse rate beats per minute)
Lasso di tempo: ten minutes results before induction
|
arterial hemoglobin functional oxygen saturation % (SpO2), pulse rate (PR) beats per minute, pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
ten minutes results before induction
|
|
PI (perfusion index)
Lasso di tempo: ten minutes when c02 insufflation is performed into the abdomen
|
arterial hemoglobin functional oxygen saturation (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
ten minutes when c02 insufflation is performed into the abdomen
|
|
PVI (pleth variability index)
Lasso di tempo: ten minutes when c02 insufflation is performed into the abdomen
|
arterial hemoglobin functional oxygen saturation (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
ten minutes when c02 insufflation is performed into the abdomen
|
|
SPO2 (hemoglobin functional oxygen saturation)
Lasso di tempo: ten minutes when c02 insufflation is performed into the abdomen
|
arterial hemoglobin functional oxygen saturation (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
ten minutes when c02 insufflation is performed into the abdomen
|
|
PR (pulse rate beats per minute)
Lasso di tempo: t2(ten minutes when c02 insufflation is performed into the abdomen
|
arterial hemoglobin functional oxygen saturation (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
t2(ten minutes when c02 insufflation is performed into the abdomen
|
|
PI (perfusion index)
Lasso di tempo: two hours during the surgery in the trendelenburg position
|
arterialhemoglobin functional oxygen saturation % (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
two hours during the surgery in the trendelenburg position
|
|
PVI (pleth variability index)
Lasso di tempo: two hours during the surgery in the trendelenburg position
|
arterialhemoglobin functional oxygen saturation % (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
two hours during the surgery in the trendelenburg position
|
|
SPO2 (hemoglobin functional oxygen saturation)
Lasso di tempo: two hours during the surgery in the trendelenburg position
|
arterialhemoglobin functional oxygen saturation % (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
two hours during the surgery in the trendelenburg position
|
|
PR (pulse rate beats per minute)
Lasso di tempo: two hours during the surgery in the trendelenburg position
|
arterialhemoglobin functional oxygen saturation % (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
two hours during the surgery in the trendelenburg position
|
|
PI (perfusion index)
Lasso di tempo: five minute send of surgery
|
arterial hemoglobin functional oxygen saturation % (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
five minute send of surgery
|
|
PVI (pleth variability index)
Lasso di tempo: five minute send of surgery
|
arterial hemoglobin functional oxygen saturation % (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
five minute send of surgery
|
|
SPO2 (hemoglobin functional oxygen saturation)
Lasso di tempo: five minute send of surgery
|
arterial hemoglobin functional oxygen saturation % (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
five minute send of surgery
|
|
PR (pulse rate beats per minute)
Lasso di tempo: five minute send of surgery
|
arterial hemoglobin functional oxygen saturation % (SpO2), pulse rate BPM (PR), pleth variability index (PVi) and pleth respiratory rate (Rrp) PI (perfusion index) values |
five minute send of surgery
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: ELA ERDEM HIDIROGLU, ANKARA ETLİK CİTY HOSPİTAL
Pubblicazioni e link utili
Pubblicazioni generali
- Yildiz GO, Hergunsel GO, Sertcakacilar G, Akyol D, Karakas S, Cukurova Z. Perioperative goal-directed fluid management using noninvasive hemodynamic monitoring in gynecologic oncology. Braz J Anesthesiol. 2022 May-Jun;72(3):322-330. doi: 10.1016/j.bjane.2021.12.012. Epub 2022 Feb 1.
- Forget P, Lois F, de Kock M. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg. 2010 Oct;111(4):910-4. doi: 10.1213/ANE.0b013e3181eb624f. Epub 2010 Aug 12.
- Ghoundiwal D, Delaporte A, Bidgoli J, Forget P, Fils JF, Van der Linden P. Effect of pneumoperitoneum on dynamic variables of fluid responsiveness (Delta PP and PVI) during Trendelenburg position. Saudi J Anaesth. 2020 Jul-Sep;14(3):323-328. doi: 10.4103/sja.SJA_737_19. Epub 2020 May 30.
- Agerskov M, Thusholdt ANW, Holm-Sorensen H, Wiberg S, Meyhoff CS, Hojlund J, Secher NH, Foss NB. Association of the intraoperative peripheral perfusion index with postoperative morbidity and mortality in acute surgical patients: a retrospective observational multicentre cohort study. Br J Anaesth. 2021 Sep;127(3):396-404. doi: 10.1016/j.bja.2021.06.004. Epub 2021 Jul 3.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- ANKARA ETLİK 1
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .