Esiti Funzionali e Controllo Utilizzando BCI Sincrono - Canada (FOCUS-CAN) (FOCUS-CAN)
Esiti Funzionali e Controllo con Synchron BCI - Canada
Functional Outcomes and Control Using Synchron BCI - Canada (FOCUS-CAN)
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Functional Outcomes and Control Using Synchron BCI - Canada (FOCUS-CAN):
The Synchron BCI motor neuroprosthesis is an implanted brain-computer interface indicated for adults with bilateral upper-limb motor impairment, including Motor Neuron Disease. The Synchron BCI is intended to replace the function of motor neurons by detecting, translating and transmitting motor-related brain signals to restore clinically meaningful control of digital devices.
The Synchron BCI is an implanted BCI device that interfaces with the brain to enable control of digital devices in individuals with bilateral upper-limb motor impairment. The Synchron BCI is designed to record volitional motor-related neural signals from the sensorimotor cortices and translate these signals into digital motor outputs to enable control of digital devices to improve functional independence. The system includes both implantable and non-implantable components. Implantable components are the Stentrode and the Transceiver.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Toronto, Canada, M5C 1R6
- St. Michael's Hospital
-
-
Ontario
-
Toronto, Ontario, Canada, M5C 1N2
- Sunnybrook Health Sciences Centre
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
INCLUSION CRITERIA:
- Able to provide informed consent to participate in the study, in the opinion of the Investigator(s).
- Diagnosis of amyotrophic lateral sclerosis or motor neuron disease, with bilateral upper-limb paresis.
- Aged 18 years or older.
- Life expectancy greater than 12 months post-implantation, in the opinion of the Investigator(s).
- Preserved precentral gyrus assessed using CT.
- Suitable vascular anatomy, in the opinion of the Investigator(s), assessed using CT venography.
- Suitable anatomy for subcutaneous pocket creation.
- Able to undergo anesthesia.
- Willing and able to comply with investigational requirements, including clinical testing visits and training visits in the home.
- Caregiver(s) willing and able to facilitate study visits, including visits at the study site and in the home, and BCI use outside of study visits (e.g., device charging).
- Patient and Caregiver fluent in English.
- Suitable home environment for BCI training, including an internet connection.
EXCLUSION CRITERIA:
- Unrealistic expectations regarding the potential benefits of the device, in the opinion of the Investigator(s).
- Active infection or unexplained fever in the 48 hours prior to informed consent.
- Major psychiatric disorder that may adversely impact the participant's safety or study compliance (e.g., severe depression, psychotic features, personality disorder, severe emotional lability, substance abuse), in the opinion of the Investigator(s).
- Dementia or cognitive dysfunction that would impact the participant's ability to participate in study activities, in the opinion of the Investigator(s).
- Active implanted device (e.g., deep brain stimulator, cardiac defibrillator, pacemaker, vagal nerve stimulator, spinal cord stimulator, diaphragmatic pacer, etc.).
- Known allergy to patient-contacting materials included in the implanted device (listed in Physician Implant Manual).
- Contraindication to angiographic imaging or iodine contrast media.
- History of central venous sinus thrombosis.
- Recent history of new venous thromboembolic event (in the 6 months prior to implant) or recurrent history of venous thromboembolic disease.
- Contraindication to antithrombotic therapy, in the opinion of the Investigator(s).
- Participant is at substantially increased risk of infection, including immunocompromised status, recurrent or chronic infection, or poorly controlled diabetes mellitus.
- Significant risk of non-healing of the subcutaneous pocket incision, including history of chronic non-healing surgical wounds or poorly controlled diabetes mellitus.
- Currently receiving or expected to require medical treatment that may be precluded by device implant, including magnetic resonance imaging, transcranial magnetic stimulation, electroconvulsive therapy, transcranial ultrasound, shortwave, microwave, and/or therapeutic ultrasound diathermy, or balloon angioplasty or stenting in the target vessel.
- Pregnant or breast feeding.
- Patients who are currently enrolled in any other clinical trial that would confound interpretation of safety or effectiveness data or may interfere with the ability to meet study requirements.
- Patients with ALS due to SOD1 mutations on gene therapy.
- Any other disease or disorder that could significantly affect participation in the study, in the opinion of the Investigator(s). Examples may include corrected vision insufficient for viewing computer screens or hearing insufficient for following verbal instructions, which might impact the participant's ability to participate in BCI training and testing.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Altro
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Altro: Single
Single Arm |
The Stentrode is an endovascular electrode array that senses electrical signals from the sensorimotor cortices. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Eventi avversi gravi correlati al dispositivo che hanno portato a morte o a un aumento permanente della disabilità fino a 90 giorni dopo l'impianto.
Lasso di tempo: 3 Mesi
|
3 Mesi
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Eventi avversi gravi correlati al dispositivo che hanno portato a morte o disabilità permanentemente aumentata fino a 1 anno dopo l'impianto.
Lasso di tempo: 12 Mesi
|
12 Mesi
|
|
Patenza del vaso target valutata mediante venografia TC a 90 e 365 giorni dall'impianto.
Lasso di tempo: 3 Mesi e 12 Mesi
|
3 Mesi e 12 Mesi
|
|
Migrazione del dispositivo valutata mediante venografia TC a 90 e 365 giorni dall'impianto.
Lasso di tempo: 3 Mesi e 12 Mesi
|
3 Mesi e 12 Mesi
|
Altre misure di risultato
Altre misure di risultato
Misura del risultato |
Lasso di tempo |
|---|---|
|
Tempo in giorni dall'impianto all'attivazione del dispositivo.
Lasso di tempo: Numero di giorni dall'impianto del dispositivo all'attivazione del dispositivo, fino a 12 mesi dopo l'impianto.
|
Numero di giorni dall'impianto del dispositivo all'attivazione del dispositivo, fino a 12 mesi dopo l'impianto.
|
|
Stabilità del segnale BCI registrato, utilizzando misurazioni mensili fino a 1 anno dopo l'impianto del dispositivo.
Lasso di tempo: 12 Mesi
|
12 Mesi
|
Collaboratori e investigatori
Sponsor
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- S-03-01
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .