Pianificazione CBCT guidata dall'Intelligenza Artificiale versus Pianificazione CBCT manuale per il posizionamento immediato di impianti (AI)
Intelligenza Artificiale Guidata Versus Pianificazione Manuale CBCT per il Posizionamento Immediato di Impianti nei Siti di Estrazione Molare: Uno Studio Randomizzato Controllato
This study evaluates whether artificial intelligence (AI)-based analysis of cone-beam computed tomography (CBCT) scans can support clinical decision-making for immediate dental implant placement in molar extraction sites.
When a molar tooth is removed, placing a dental implant immediately may reduce treatment time and preserve surrounding bone. However, immediate implant placement is not always possible and depends on the anatomy of the extraction socket, particularly the interradicular septum (the bone between the roots). CBCT imaging is routinely used to assess this anatomy before surgery. Traditionally, radiologists manually evaluate these scans. Recently, AI-based tools have been developed to automatically analyze CBCT images.
In this randomized controlled trial, patients requiring molar extraction and potential immediate implant placement will be assigned to one of two planning approaches: AI-guided CBCT assessment or conventional manual CBCT assessment. The operating surgeon will use the assigned planning report to guide treatment decisions.
The primary outcome of the study is the feasibility of immediate implant placement, defined as successful implant placement with achievement of primary stability during surgery. Secondary outcomes include surgical time, need for changes to the treatment plan, and implant stability measurements.
The goal of this study is to determine whether AI-assisted CBCT analysis performs similarly to, or improves upon, conventional manual radiologic assessment in supporting safe and effective immediate implant placement.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
This study is a prospective, parallel-arm, randomized controlled clinical trial designed to evaluate the clinical impact of artificial intelligence (AI)-based CBCT analysis on decision-making for immediate implant placement in molar extraction sites.
Following eligibility confirmation and informed consent, participants requiring molar extraction with potential immediate implant placement will undergo standardized preoperative cone-beam computed tomography (CBCT) imaging. Participants will be randomly allocated in a 1:1 ratio to one of two planning workflows:
AI-guided planning arm: CBCT scans will be analyzed using a pre-specified, locked AI-based segmentation and socket assessment model. The AI system will quantify interradicular septum dimensions and generate a feasibility classification based on predefined anatomical criteria.
Manual planning arm: CBCT scans will undergo conventional manual segmentation and assessment by an experienced radiologist using the same predefined anatomical criteria for feasibility determination.
In both arms, feasibility recommendations will be based on identical, prospectively defined decision thresholds to ensure comparability between planning methods. The operating surgeon will receive only the planning report corresponding to the assigned allocation.
All surgeries will be performed according to a standardized surgical protocol. The primary outcome is intraoperative feasibility of immediate implant placement, defined as successful implant placement in the extraction socket with achievement of primary stability according to prespecified stability criteria documented in the operative record. Cases in which implant placement is not performed or is aborted due to inability to achieve adequate primary stability will be classified as non-feasible.
Secondary outcomes include operative time, need for intraoperative modification of the treatment plan, insertion torque values, and any intraoperative complications.
Outcome assessment will be performed by an independent assessor blinded to allocation. AI analysis will be conducted using a locked model without post hoc modification.
The study aims to determine whether AI-guided CBCT planning is non-inferior or superior to conventional manual CBCT assessment in supporting immediate implant placement decisions.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Cairo, Egitto
- Shalash Implant education
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Adults≥18 years are able to provide informed consent. Indicated for the extraction of a molar tooth (maxillary or mandibular) with planned implant-supported rehabilitation.
- Candidate for immediate implant placement attempt based on preoperative clinical evaluation and CBCT availability.
- Preoperative CBCT will be acquired using the study imaging protocol within a defined window (e.g., ≤4 weeks before surgery).
- Adequate oral hygiene and periodontal condition compatible with implant surgery (e.g., treated/stable periodontal status per clinician judgement).
Exclusion Criteria:
- Pregnancy or breastfeeding (due to imaging/surgical considerations).
- Uncontrolled systemic disease or medical contraindication to oral surgery/implant placement (e.g., uncontrolled diabetes, immunosuppression as judged by clinician).
- History of head and neck radiotherapy in the implant region. Use of medications associated with compromised bone healing where immediate implant placement is not advised (e.g., high-dose antiresorptives/IV bisphosphonates; you can specify per your clinic policy).
- Acute uncontrolled infection at the site requiring staged management (e.g., spreading cellulitis/abscess) or other condition precluding immediate placement per surgeon judgement.
- Need for simultaneous major augmentation that precludes immediate implant placement (e.g., extensive ridge reconstruction planned at the same surgery rather than socket-level grafting).
- Inadequate CBCT quality for segmentation/measurement (motion artifacts, incomplete field of view, or metal artifact obscuring the septum).
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Doppio
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: AI assisted CBCT
Participants randomized to this arm will undergo preoperative cone-beam computed tomography (CBCT) imaging as part of standard diagnostic workup for molar extraction with potential immediate implant placement. CBCT datasets will be processed using a pre-specified, locked artificial intelligence (AI)-based segmentation and socket assessment model. The AI system will automatically segment the extraction socket anatomy, quantify interradicular septum dimensions, and generate a structured feasibility assessment according to predefined anatomical decision thresholds established in the study protocol. A standardized AI-generated planning report, including septum measurements and feasibility classification, will be provided to the operating surgeon prior to surgery. The surgeon will use this report to guide preoperative planning and intraoperative decision-making. Surgical procedures will be performed according to a standardized surgical protocol. Immediate implant placement will be attempte |
The intervention consists of a fully automated, deep learning-based CBCT analysis pipeline designed for extraction socket segmentation and quantitative interradicular septum assessment. The AI system utilizes a pre-trained convolutional neural network architecture to perform voxel-level segmentation of the extraction socket and surrounding alveolar structures on CBCT datasets. Following segmentation, the model automatically quantifies predefined anatomical parameters, including interradicular septum width at standardized reference levels and socket morphology classification. These measurements are generated using algorithmically defined geometric landmarks, ensuring consistent spatial reference across cases. Feasibility for immediate implant placement is determined using a prespecified, protocol-defined decision rule applied to AI-derived quantitative parameters. |
|
Comparatore attivo: Manual CBCT segmented
Participants randomized to this arm will undergo preoperative CBCT imaging as part of the standard diagnostic workup for molar extraction with potential immediate implant placement. CBCT datasets will be evaluated using conventional manual segmentation and radiologic assessment performed by an experienced radiologist. Interradicular septum dimensions and socket morphology will be assessed according to predefined anatomical criteria specified in the study protocol. Feasibility for immediate implant placement will be determined using the same prospectively defined decision thresholds applied in the intervention arm. A standardized manual planning report, including septum measurements and feasibility classification, will be provided to the operating surgeon before surgery. The surgeon will use this report to guide preoperative planning and intraoperative decision-making. Surgical procedures will be performed according to the same standardized surgical protocol |
The control intervention consists of conventional radiologic evaluation of CBCT datasets using manual segmentation and operator-driven anatomical assessment. CBCT scans will be reviewed by an experienced oral and maxillofacial radiologist using standard imaging software. Interradicular septum dimensions will be determined through manual identification of anatomical landmarks and measurement using software-based calipers at predefined reference levels. Socket morphology classification will be assigned based on visual interpretation and application of the same predefined anatomical criteria specified in the study protocol. Feasibility for immediate implant placement will be determined by applying the protocol-defined decision thresholds to manually obtained measurements. All measurements and classifications will be documented in a structured planning report provided to the operating surgeon. Unlike the AI-guided intervention, this workflow relies on manual landmark identification and ope |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Immediate implant feasability
Lasso di tempo: During the implant surgery-intra operative after flap elevation
|
Proportion of sites with successful immediate implant placement with primary stability at the index surgery (feasible vs not feasible). |
During the implant surgery-intra operative after flap elevation
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Planning time (minutes)
Lasso di tempo: Preoperative before the surgery
|
Time to generate the report (AI processing time vs manual segmentation/assessment time). |
Preoperative before the surgery
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Direttore dello studio: Mahmoud Shalash, PhD, Shalash Implant education
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 5-9-23
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .