Use of Various Types of Introducers in Conventional Radial Access (TIRE)
The purpose of this intervention study is to compare different types of radial introducers used in traditional radial access in terms of the incidence of complications.
The main questions it aims to answer are:
- Does a smaller outer diameter of the introducer reduce the risk of complications associated with radial access?
- Does the presence of an outer hydrophilic coating on the introducer reduce the risk of complications associated with radial access?
- Does the use of an introducer with a smaller outer diameter and an outer hydrophilic coating reduce the risk of complications associated with radial access? The researchers will compare the number of complications associated with radial access when using conventional diameter, uncoated radial introducers, conventional diameter introducers with an outer hydrophilic coating, or reduced outer diameter introducers with an outer hydrophilic coating.
During the scheduled revascularization procedure, the participants will undergo radial artery catheterization using one of the types of introducers. Complications from the radiation access will be recorded by doctors within 72 hours after the intervention.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
- Procedura: catheterization of the radial artery using an classic introducer
- Procedura: catheterization of the radial artery using an introducer with a standard outer diameter and an outer hydrophilic coating
- Procedura: catheterization of the radial artery using an introducer with a reduced outer diameter and an outer hydrophilic coating
Descrizione dettagliata
Objective: to compare different types of radial introducers used in conventional radial access by the frequency of complications.
Scientific hypotheses:
- The risk of acute radial artery occlusion depends on the outer diameter of the introducer.
- The risk of acute radial artery occlusion depends on the presence of an outer hydrophilic coating on the introducer.
- The risk of persistent radial artery spasm depends on the presence of an outer hydrophilic coating on the introducer.
- The risk of persistent radial artery spasm depends on the outer diameter of the introducer.
Patients were enrolled by endovascular specialists with experience of at least 250 radial-access procedures per year.
Inclusion criteria: clear pulsation of the right radial artery, indications for percutaneous coronary intervention.
Exclusion criteria: previous unsuccessful radial artery catheterization; concomitant pathology limiting patient survival; disorders of the blood coagulation system (hemophilia, thrombocytopathy, etc.); previous coronary artery bypass grafting; occlusion of the right radial artery.
The required sample size was calculated using the method of M. Bland for a high-precision study. The required significance level (α) was 0.001 and the statistical power was 95%. The expected rate of radial artery occlusion in the Rad, Rad polymer, and Rad slender groups was assumed to be 12%, 8%, and 8%, respectively. Under these conditions, the calculated sample size was 2723 patients. The planned loss during the study was 20%. Thus, the minimum sample size was 3268 patients.
The study had an experimental design and complied with the CONSORT protocol. A simple randomization method using a random-number generator was chosen. The type of randomization was permuted block randomization. The total block size was 3000, and the allocation ratio between the groups was 1:1:0.7.
Puncture of the right radial artery was performed after local anesthesia with a 2% lidocaine solution. The radial artery was punctured at the typical site using the puncture needle included in the introducer set, with only the anterior wall being punctured. The type of introducer was selected by randomization using a random-number method, and depending on this assignment the patient was allocated to one of the groups.
All patients underwent percutaneous coronary angioplasty with coronary artery stenting via the right radial artery. The radial artery catheterization technique did not differ between groups. The type of introducer was selected by randomization using a random-number method, and depending on this assignment the patient was allocated to one of the groups. In the Rad group , introducers without a hydrophilic coating were used; in the Rad polymer group , introducers with a hydrophilic coating were used; and in the Rad slender group , thin-walled introducers with a hydrophilic coating were used. The access site was examined within 3 hours after the intervention and then, in the absence of complaints, again at bandage removal. After bandage removal, patients underwent ultrasound examination to confirm radial artery patency. Complications from the radiation access will be recorded by doctors within 72 hours after the intervention.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Kostroma Oblast
-
Kostroma, Kostroma Oblast, Russia, 156013
- E.I. Korolev Kostroma Regional Clinical Hospital
-
-
Moscow
-
Moscow, Moscow, Russia, 119071
- Central Clinical Hospital of St. Alexy Metropolitan of Moscow of the Moscow Patriarchate of the Russian Orthodox Church
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
- clear pulsation of the right radial artery
- indications for percutaneous coronary intervention
Exclusion Criteria:
- previous unsuccessful radial artery catheterization
- concomitant pathology limiting patient survival
- disorders of the blood coagulation system (hemophilia, thrombocytopathy, etc.)
- previous coronary artery bypass grafting
- occlusion of the right radial artery
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Terapia di supporto
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Doppio
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Comparatore attivo: Rad classic
Introducer with a standard outer diameter and no external hydrophilic coating
|
The right radial artery was punctured under local anesthesia with a 2% lidocaine solution. The radial artery was punctured at a typical location using a puncture needle included in the catheterization kit, puncturing only the anterior wall. An introducer with a standard outer diameter and no external hydrophilic coating was inserted. 5,000 IU of heparin in saline solution was injected into the catheterized artery. All injected solutions, including radiocontrast agents, had a temperature of 36.5-36.7 °C. Hemostasis was achieved by applying a pressure bandage. The access site was examined 3 hours after the intervention, and then, if there were no complaints, it was examined again when the bandage was removed. After the bandage was removed, patients underwent an ultrasound examination to confirm the patency of the radial artery. Complications were recorded within 3 days after the intervention. |
|
Sperimentale: Rad polymer
Introducer with a standard outer diameter and an outer hydrophilic coating
|
Description: The right radial artery was punctured under local anesthesia with a 2% lidocaine solution. The radial artery was punctured at a typical location using a puncture needle included in the catheterization kit, puncturing only the anterior wall. An introducer with a standard outer diameter and an outer hydrophilic coating was using. 5,000 IU of heparin in saline solution was injected into the catheterized artery. All injected solutions, including radiocontrast agents, had a temperature of 36.5-36.7 °C. Hemostasis was achieved by applying a pressure bandage. The access site was examined 3 hours after the intervention, and then, if there were no complaints, it was examined again when the bandage was removed. After the bandage was removed, patients underwent an ultrasound examination to confirm the patency of the radial artery. Complications were recorded within 3 days after the intervention. |
|
Sperimentale: Rad slender
Introducer with a reduced outer diameter and an outer hydrophilic coating
|
Description: The right radial artery was punctured under local anesthesia with a 2% lidocaine solution. The radial artery was punctured at a typical location using a puncture needle included in the catheterization kit, puncturing only the anterior wall. An introducer with a reduced outer diameter and an outer hydrophilic coating was using. 5,000 IU of heparin in saline solution was injected into the catheterized artery. All injected solutions, including radiocontrast agents, had a temperature of 36.5-36.7 °C. Hemostasis was achieved by applying a pressure bandage. The access site was examined 3 hours after the intervention, and then, if there were no complaints, it was examined again when the bandage was removed. After the bandage was removed, patients underwent an ultrasound examination to confirm the patency of the radial artery. Complications were recorded within 3 days after the intervention. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Acute radial artery occlusion after catheterization
Lasso di tempo: Within 72 hours after radial artery catheterization
|
Acute radial artery occlusion was confirmed by ultrasound examination
|
Within 72 hours after radial artery catheterization
|
|
Radial artery perforation
Lasso di tempo: Perioperative/Periprocedural
|
Angiography-confirmed perforation of the radial artery
|
Perioperative/Periprocedural
|
|
Radial artery false aneurysm
Lasso di tempo: Within 72 hours after radial artery catheterization
|
A false aneurysm of the radial artery was confirmed by ultrasound examination
|
Within 72 hours after radial artery catheterization
|
|
Hematoma by classification EASY Grade II
Lasso di tempo: Within 72 hours after radial artery catheterization
|
Hematoma by classification EASY Grade II was confirmed by ultrasound examination
|
Within 72 hours after radial artery catheterization
|
|
Persistent radial artery spasm
Lasso di tempo: Perioperative/Periprocedural
|
Persistent radial artery spasm confirmed by angiography
|
Perioperative/Periprocedural
|
Collaboratori e investigatori
Sponsor
Sponsor
Collaboratori
Collaboratori
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 260/1
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Periodo di condivisione IPD
Tipo di informazioni di supporto alla condivisione IPD
- STUDIO_PROTOCOLLO
- LINFA
- RSI
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .