Radiological Comparison Between Single-Leg and Double-Leg Stance in the Assessment of Genu Varum: Pre- and Postoperative Evaluation and Functional Outcomes
Genu varum, commonly known as bow-legged deformity, is characterized by an outward angulation of the knee joint that disrupts normal lower limb alignment and weight distribution(1,2). This condition alters the mechanical axis of the limb, often increasing medial compartment loading, which can accelerate degenerative joint changes and pain. Radiographic assessment plays a central role in quantifying the deformity, typically measured through parameters such as the hip-knee-ankle (HKA) angle, mechanical axis deviation (MAD), and medial proximal tibial angle (MPTA)(1,2).
Weight-bearing posture during imaging significantly influences these alignment parameters. Several studies have demonstrated that single-leg stance radiographs produce more physiologically representative alignment measurements than double-leg stance, since the single-leg condition better simulates natural load distribution and joint reaction forces during locomotion(3,4). The single-leg stance increases joint compression and reveals hidden malalignments that may be masked in double-leg or non-weight-bearing positions. Consequently, preoperative evaluations based solely on double-leg stance may underestimate the severity of genu varum deformity(3,4).
Surgical correction, through techniques such as high tibial osteotomy or guided growth, aims to restore the mechanical axis to a near-neutral position, improving load symmetry and delaying degenerative changes(4,5). Postoperative evaluation is essential for monitoring realignment success and predicting functional recovery, which often involves comparing radiological correction with clinical outcomes such as range of motion, pain reduction, and activity resumption. However, the correspondence between radiographic correction measured under different stance conditions and postoperative function remains poorly defined(6,7).
Recent evidence suggests that patients assessed preoperatively under single-leg stance conditions may have more accurate predictions of postoperative alignment and function than those evaluated under double-leg stance (5,6). Furthermore, differences between stance types may influence surgical planning decisions, including the degree of correction targeted and the fixation technique used. Functional outcomes after genu varum correction depend not only on bony realignment but also on balanced muscular forces, proprioception, and joint stability - factors more dynamically engaged in single-leg stance evaluation(7,8).
Despite increasing recognition of weight-bearing differences in radiological evaluation, limited research directly compares single-leg versus double-leg stance assessment for genu varum across preoperative and postoperative stages. Establishing which stance provides a more reliable correlation with functional outcomes could refine surgical planning, enhance rehabilitation monitoring, and standardize postoperative evaluation protocols for improved patient outcomes.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
• Patients aged 18-65 years diagnosed with genu varum requiring surgical correction (e.g., high tibial osteotomy )
- Willingness to participate and provide informed consent.
- Ability to stand independently for radiographic assessment.
- No prior lower limb surgery within the last year.
Exclusion Criteria:
Patients with genu varum with Blount's disease, rickets and metabolic bone disease.
- History of knee surgery within the last year.
- Neurological, psychological, or systemic disorders affecting gait or stance.
- Inadequate preoperative or follow-up radiographs.
- Inability to comply with follow-up schedule.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
|---|
|
Group A
single-leg stance group
|
|
Group B
double-leg stance group
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
radiographic alignment parameters
Lasso di tempo: 3 months postoperative
|
Difference in radiographic alignment parameters between single-leg and double-leg stance pre- and postoperatively.
|
3 months postoperative
|
Collaboratori e investigatori
Sponsor
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- RadiologicalSingle Double leg
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .