A Comparison Between Ischial-Containment and Sub-Ischial Prosthetic Sockets to Determine Their Effects on Secondary Health Conditions

12 agosto 2026 aggiornato da: VA Office of Research and Development
Long-term above-knee prosthesis users are at an increased risk of developing secondary musculoskeletal conditions compared to the general able-bodied population. One secondary physical concern is low back pain (LBP), for which the development is not entirely understood, but in above-knee prosthesis users it is believed to relate to asymmetries and compensations that are typically demonstrated and required to stand and walk. Understanding spinal motion and compensations will enhance our knowledge of the factors contributing to LBP, and possibly lead to the development of new prosthetic and therapeutic interventions to prevent or alleviate LBP, thereby improving mobility and quality of life for prosthesis users.

Panoramica dello studio

Stato

Non ancora reclutamento

Condizioni

Descrizione dettagliata

The purpose of this study is to investigate and compare the effects of the standard ischial containment (IC) socket to a sub-ischial (SI) socket design on the spinal and pelvic motions and leg length (LLD) discrepancies of transfemoral prosthesis users. Data will be collected from 2 groups of transfemoral prosthesis users (15 SI socket wearers and 15 IC socket wearers) and a group of 15 able-bodied (AB) control participants. Gait and standing analyses will be conducted on each participant using a marker based motion capture system. Prosthesis users will wear their own conventional sockets for the gait and standing analyses. Kinematic and kinetic data will be analyzed for differences between the 2 groups of socket wearers and will also be compared to the control group.

The specific aims and hypotheses of this project are:

Aim 1: To measure dynamic leg length and kinematics of the pelvis and spinal segments in unilateral, transfemoral prosthesis users during gait. Quantitative motion analyses will be performed on two groups of 15 research participants with lower limb amputation using 2 different socket designs (IC and SI) walking over level ground at three self-selected walking speeds (normal, moderately fast, fastest). Data will be compared between socket type and to an AB control group. Hypothesis 1a-IC socket wearers will have a greater anterior pelvic tilt compared to SI socket wearers and AB controls, and they will exhibit considerably greater rotations of the pelvis and spinal segments during walking. Hypothesis 1b-The EMG activity of the lumbar erector spinae for SI socket users will better approximate the patterns of AB controls as compared to IC socket wearers. Hypothesis 1c-The dynamic LLD will be greater for IC socket users compared to SI socket wearers and AB controls.

Aim 2: To measure pelvic orientation and static leg length in unilateral, transfemoral prosthesis users during standing. A multi-segment model of the spine and pelvis will be used to determine neutral spinal, pelvis, and prosthetic alignment during standing for the research and AB control participants. Hypothesis 2a-IC socket wearers will demonstrate greater anterior pelvic tilt during standing compared to SI socket wearers and control participants. Hypothesis 2b-The prosthetic and sound leg lengths for both prosthesis user groups will be within 1.0 cm of each other during standing.

Aim 3: To estimate joint contact forces in the legs and lower back of unilateral, transfemoral prosthesis users and controls during gait. Computational musculoskeletal simulations will be used to comprehensively evaluate the data from Aim 1 to compare the lumbar joint loads between IC and SI socket wearers. Hypothesis 3-IC socket wearers will exhibit greater lumbar joint loads than SI socket wearers.

Tipo di studio

Osservativo

Iscrizione (Stimato)

45

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Luoghi di studio

    • Illinois
      • Chicago, Illinois, Stati Uniti, 60612
        • Jesse Brown VA Medical Center, Chicago, IL
        • Contatto:
        • Contatto:
        • Investigatore principale:
          • Rebecca Stine, MS

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto
  • Adulto più anziano

Accetta volontari sani

Sì

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

Thirty unilateral transfemoral prosthesis users (15 with an ischial containment socket and 15 with a sub-ischial socket) and 15 able-bodied control participants.

Descrizione

Inclusion Criteria:

For all participants:

  • Ability to complete the experimental protocol without undue fatigue or health risks
  • Low Back Pain scale assessment (0-10) less than 4 (activities of daily living or quality of life not impacted)

In addition for persons with lower limb amputation:

  • Prosthesis user for a minimum of 2 years with their current socket design
  • Good fit with either an ischial containment (IC) or sub-ischial (SI) socket
  • Good skin integrity on their residual limb upon visual inspection
  • Does not require the use of assistive devices to walk

Exclusion Criteria:

  • Previously diagnosed with a spine condition (e.g., pinched nerve, bulging disc, etc.)
  • Previously diagnosed with an orthopedic or neuromuscular condition that may affect walking or balance (e.g., ankle fusion, Parkinson's disease, stroke, etc.)

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

Coorti e interventi

Gruppo / Coorte
Ischial Containment Socket user
Person with unilateral transfemoral amputation wearing an ischial containment socket
Sub-Ischial Socket user
Person with unilateral transfemoral amputation wearing a sub-ischial socket
Able-bodied control
Person without an amputation

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Anterior Pelvic Tilt Angle Between the IC Socket wearers and the SI Socket wearers/Able-Bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
Anterior Pelvic Tilt will be calculated for all participants during the walking and standing trials. Participants will walk along a 10 meter walkway at varying speeds. Quantitative motion analysis using a marker based motion measurement system will be used to calculate anterior pelvic tilt.
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Electromyography (EMG) Activity of the Lumbar Erector Spinae Between the IC Socket wearers and the SI Socket wearers/Able-bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
EMG activity will be assessed using surface electrodes attached bilaterally to the erector spinae at and below T12/L1 and on the external oblique muscle. Data will be collected during the quantitative motion analysis.
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
Lumbar Flexion Between the IC Socket wearers and the SI Socket wearers/Able-bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
Lumbar flexion will be calculated for all participants during the walking and standing trials. Participants will walk along a 10 meter walkway at varying speeds. Quantitative motion analysis using a marker based motion measurement system will be used to calculate anterior pelvic tilt.
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
Hip Joint Range of Motion (ROM) between the IC Socket wearers and the SI Socket wearers/Able-bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
Hip Joint ROM will be calculated for all participants during the walking trials. Participants will walk along a 10 meter walkway at varying speeds. Quantitative motion analysis using a marker based motion measurement system will be used to calculate hip joint ROM.
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
Dynamic Leg Length Discrepancy (LLD) Between the IC Socket wearers and the SI Socket wearers/Able-bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
Dynamic LLD will be calculated for all participants during the walking trials. Participants will walk along a 10 meter walkway at varying speeds. Quantitative motion analysis using a marker based motion measurement system will be used to calculated dynamic LLD.
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
Peak Lumbar Joint Loading Between the IC Socket wearers and the SI Socket wearers/Able-bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
Lumbar joint loading during walking will be analyzed by performing musculoskeletal modeling simulations using data collected during the quantitative motion analysis.
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Investigatori

  • Investigatore principale: Rebecca Stine, MS, Jesse Brown VA Medical Center, Chicago, IL

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 gennaio 2027

Completamento primario (Stimato)

1 luglio 2030

Completamento dello studio (Stimato)

31 dicembre 2030

Date di iscrizione allo studio

Primo inviato

4 agosto 2026

Primo inviato che soddisfa i criteri di controllo qualità

12 agosto 2026

Primo Inserito (Effettivo)

17 agosto 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

17 agosto 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

12 agosto 2026

Ultimo verificato

1 agosto 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • RRD2-014-25W

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .