- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT02017652
Validation of Fore-Sight Cerebral & Tissue Oximeter Saturation Measurements on Neonates ≤ 5 kg (FORE-SIGHT)
6 ottobre 2017 aggiornato da: Anup Katheria, M.D., Sharp HealthCare
Validation of FORE-SIGHT Cerebral & Tissue Oximeter to Measure Cerebral & Somatic Tissue Oxygen Saturation Measurements at Different Body Locations on Neonates ≤ 5 kg
CASMED, INC. wishes to validate the next generation FORE-SIGHT-II (FS-II) NIRS tissue oximeter monitor for neonatal brain and somatic tissue oxygen saturation (StO2) measurements.
This monitor was recently FDA cleared for use on adult subjects.
Panoramica dello studio
Stato
Completato
Condizioni
Descrizione dettagliata
- Validate FS-II abdominal StO2 measurements from the intestines, liver, and flank to umbilical venous and arterial blood oxygen saturation.
- Validate FS-II cerebral StO2 measurements against the predicate FDA cleared FORE-SIGHT-I (FS-I) monitor.
- Collect data from FS-II sensors on the forehead and abdomen (intestine) for 24 hours to compare dynamic changes vs the pulse oximeter. For larger neonates, add a predicate FS-I sensor to the opposite side forehead for dynamic comparison to FS-II measurements.
- Obtain abdominal Near Infrared Spectroscopy (NIRS) data simultaneous with accepted measures of bowel motility (a. frequency and composition of stools, and b. Ultrasound assessment for the frequency and magnitude of bowel peristalsis, if available).
Tipo di studio
Osservativo
Iscrizione (Effettivo)
19
Contatti e Sedi
Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.
Luoghi di studio
-
-
California
-
San Diego, California, Stati Uniti, 92123
- Sharp Mary Birch Hospital for Women and Newborns
-
-
Criteri di partecipazione
I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.
Criteri di ammissibilità
Età idonea allo studio
Non più vecchio di 1 settimana (Bambino)
Accetta volontari sani
No
Sessi ammissibili allo studio
Tutto
Metodo di campionamento
Campione non probabilistico
Popolazione di studio
Neonatal subjects (32 to 36 and 6/7 weeks), with umbilical venous catheterization will be enrolled from the NICU.
Demographic information of the subject will be recorded, including race, gender, weight, gestational age (GA), study age, and diagnosis.
Descrizione
Inclusion Criteria:
Neonatal subjects (32 to 36 and 6/7 weeks), with umbilical venous catheterization will be enrolled from the Neonatal Intensive Care Unit.
Exclusion Criteria:
Enrollment in other studies during study period. Inability to tolerate ultrasounds or NIRS sensors
Piano di studio
Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: Coorte
- Prospettive temporali: Prospettiva
Coorti e interventi
Gruppo / Coorte |
---|
Preterm Infants
Preterm infants 32 to 36 weeks will be eligible for this study
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
---|---|---|
StO2 measurement from intestines, liver and flank at time of venous and arterial blood oxygen saturation.
Lasso di tempo: 1 hour
|
At or immediately following an umbilical venous blood draw for CO-oximetry, the FS-II NIRS Small sensor will be briefly placed on the abdominal wall for spot check measurements over the 1) left & 2) right flank, 3) liver and on three intestine locations: just inferior and lateral to the umbilicus in the 4) Right Lower Quadrant (RLQ) and 5) Left Lower Quadrant (LLQ) positions, as well as 6) Mid Lower Quadrant (MLQ).
Then a reference FS-I measurement of the 7) flank for 2 minutes will be done.
|
1 hour
|
Cerebral StO2 measurements from Fore-Sight FS-II monitor and Fore-Sight-I (FS-I) monitor.
Lasso di tempo: 1 hour
|
Following abdominal measurements, the FS-II Small sensor will be placed on the head with the following positions in the following sequence 1) forehead, over the frontal cortex for two minutes; 2) the FS-II sensor is lifted off the head and placed back in the same forehead position to make a repeat measurement for two minutes; and 3) on the side of the head above the ear (frontal and parietal cortex) for two minutes.
For reference cerebral measurements, a FDA cleared FS-I Small sensor will be placed on the 4) forehead for two minutes; 5) the FS-I sensor will be removed and replaced on the same forehead position to make a repeat measurement for two minutes.
The sensors will take a measurement of 2 minutes in each position and 10 minutes total.
|
1 hour
|
Pulse and Tissue oxygen saturation and infant activity
Lasso di tempo: 24 hours
|
Then two FS-II Small sensors will be attached longer term, one sensor on the forehead and one sensor on the abdomen (RLQ), with neonatal adhesives to allow monitoring for up to 24 hours.
Dynamic changes of StO2 at these locations will be observed, along with pulse oximetry SpO2 to capture any acute events such as apnea and bradycardia, which will help in modeling and verifying dynamic StO2 change behavior within the FS-II algorithm.
FS-II, and pulse oximetry data will be collected simultaneously on a laptop computer.
|
24 hours
|
Stool Interference Index over 24 hrs.
Lasso di tempo: 24 hours
|
To calculate abdominal StO2 over the intestine regions, FORE-SIGHT also measures a stool interference index, which is used to compensate the algorithm to calculate StO2 correctly.
This stool interference index is hypothesized to be also useful as a bowel motility index based on its variability over time.
To test this hypothesis, the following two references for bowel motility will be tested: a) the study site will minimally record the number of stools for a period up to 24 hours.
The event field in the laptop computer will be used to note each observation.
b) if the study site has the capacity, abdominal ultrasound will be used to observe for the frequency and magnitude of bowel peristalsis.
These impressions will be added to an event field in the laptop computer.
|
24 hours
|
Collaboratori e investigatori
Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.
Sponsor
Investigatori
- Investigatore principale: Anuup Katheria, MD, Sharp Mary Birch Hospital for Women & Newborns
Studiare le date dei record
Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.
Studia le date principali
Inizio studio
1 dicembre 2013
Completamento primario (Effettivo)
1 dicembre 2014
Completamento dello studio (Effettivo)
1 dicembre 2014
Date di iscrizione allo studio
Primo inviato
11 dicembre 2013
Primo inviato che soddisfa i criteri di controllo qualità
16 dicembre 2013
Primo Inserito (Stima)
23 dicembre 2013
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
9 ottobre 2017
Ultimo aggiornamento inviato che soddisfa i criteri QC
6 ottobre 2017
Ultimo verificato
1 ottobre 2017
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- FORE-SIGHT
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .