新規Enovaプレロード眼内レンズ及びカートリッジシステムの信頼性と有効性
新Enovaプレロード眼内レンズおよびカートリッジシステムの信頼性と有効性
Evaluation of the safety and efficacy of the new Enova® preloaded monofocal intraocular lens and cartridge injector system in cataract surgery
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
詳細な説明
In this prospective and single-center clinical study, the safety and efficacy of the Enova PGF3 intraocular lens (IOL) and cartridge injector system will be evaluated.
The Enova PGF3 cartridge injector system is designed to be used in cataract surgeries. Cataract patients aged 40 years and older, both male and female, without any serious ocular disease other than cataracts, will undergo IOL implantation following cataract surgery. It is planned to perform a total of 200 implantations with either unilateral or bilateral implantation of the participants' eyes.
Postoperative visual acuity, refraction, patient satisfaction, and adverse events will be monitored during follow-up visits at day 1, week 1, and month 1.
The primary objectives of the study are to achieve an uncorrected distance visual acuity of 20/20 or better, and to maintain an error and complication rate related to the preloaded system below 7.5%. Secondary objectives include evaluating patient satisfaction and assessing whether surgeons find the preloaded system easy to use and if it meets their expectations.
The primary endpoints are refractive stability within ±0.50 D, uncorrected distance visual acuity of 20/20 or better, and a general clinical performance rating of the preloaded system with a score of 95% or higher. Secondary endpoints include the duration of surgery, accuracy of lens positioning, surgical complications, surgeon-reported ease of use, and patient satisfaction survey results meeting expectations.
As a safety parameter, adverse events reported in postoperative surgical reports will be evaluated.
研究の種類
研究の種類
入学 (実際)
入学
段階
段階
- 適用できない
連絡先と場所
研究場所
-
-
Fatih
-
Istanbul、Fatih、トルコ(Türkiye)、34250
- Istanbul University Istanbul Medical Faculty Ophthalmology Department
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Adults of either sex.
Age 40 years or older.
Willing and able to provide written informed consent and comply with planned study visits and procedures.
Healthy ocular status, with no ocular pathology other than cataract and mild refractive error.
Potential visual acuity of 20/32 (0.2 logMAR) or better in both eyes.
Presence of regular corneal astigmatism suitable for treatment with the study device.
Candidates for uncomplicated cataract surgery using the study device.
Exclusion Criteria:
- Irregular corneal astigmatism (e.g., keratoconus).
Corneal pathology (e.g., scar, dystrophy, pterygium, moderate to severe dry eye).
Monocular conditions (e.g., amblyopia).
Previous corneal surgery, including radial keratotomy, corneal refractive surgery, corneal transplantation, DSAEK, or lamellar keratoplasty.
Previous anterior or posterior segment surgery (e.g., vitrectomy, laser iridotomy).
Diabetic retinopathy.
Macular pathology (e.g., age-related macular degeneration [ARMD], epiretinal membrane [ERM]).
History of retinal detachment.
Surgical complications that may affect study outcomes, such as:
Decentration due to capsulorhexis issues
Improper lens placement
Inadequate or missing postoperative capsular support
Posterior capsular rupture
Vitreous loss
Iris damage (tear, rupture, etc.)
Acute or chronic ocular diseases known to affect visual acuity or study outcomes (e.g., immunosuppressed state, connective tissue disease, clinically significant atopic disease, diabetes, or other systemic or ocular conditions).
Participation in any investigational drug or device study within 30 days prior to study start, or ongoing participation in another study.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
アーム数
武器と介入
参加者グループ / アーム参加者グループ / アーム |
介入・治療介入・治療 |
|---|---|
|
実験的:Patients who need cataract surgery
Participants will undergo standard cataract surgery using the new preloaded intraocular lens (IOL) system. The intervention involves implantation of the preloaded IOL following routine phacoemulsification techniques. |
This intervention uses a preloaded IOL delivery system, which allows for a single-use, sterile implantation during standard phacoemulsification cataract surgery. Unlike standard manually loaded IOLs, this system reduces preparation time and minimizes handling of the lens, potentially improving surgical efficiency and maintaining lens sterility. |
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Uncorrected Distance Visual Acuity (UDVA) - Photopic Conditions
時間枠:1 month postoperatively
|
Proportion of eyes achieving 20/20 or better uncorrected distance visual acuity under photopic conditions. |
1 month postoperatively
|
|
Subjective Refractive Error
時間枠:1 month postoperatively
|
Eyes with a postoperative refractive error within ±0.50 diopters of the intended target. |
1 month postoperatively
|
|
Overall Clinical Performance of the Preloaded IOL System
時間枠:1 month after surgery
|
Surgeon-rated assessment of the general clinical performance of the preloaded system by The ENOVA PGF3 Questionnaire. This questionnaire is a 14-item, study-specific, non-validated survey developed to evaluate surgeons' experience with an intraocular lens (IOL) preloaded delivery system. Eleven items are rated on a 5-point Likert scale with the following scoring structure:
Some additional items are Yes/No questions and do not contribute to the numerical total score. The total numerical score is calculated by summing the 11 Likert-scaled items. Total score range: 11 to 55, with higher scores indicating better performance and more favorable user experience. |
1 month after surgery
|
二次結果の測定
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Preloaded System Evaluation Patient Questionnaire
時間枠:Baseline (preoperative) and 1 month postoperatively
|
Patient-reported outcomes assessing whether expectations for visual improvement and overall satisfaction were met.The questionnaire consists of 14 items assessing a patient's self-reported difficulty in performing vision-related daily activities. Each activity is rated using a 0-4 scale, where: 4 = No difficulty 3 = Mild difficulty 2 = Moderate difficulty 1 = Severe difficulty 0 = Unable to perform the activity The total score is calculated by summing responses across all 14 items. Total possible score range: 0 to 56 Higher scores indicate better visual function and less activity limitation. Lower scores indicate worse visual function. |
Baseline (preoperative) and 1 month postoperatively
|
|
Surgical Procedure Assessment
時間枠:Intraoperative
|
Surgeon-reported ease of lens implantation and accuracy of lens placement, evaluating whether expectations for procedural handling were met.The surgeon notes, during the operative visit, the location of the incision, the size of the incision, whether the implantation system is compatible with the wound site, how many seconds the implantation time is shortened, and whether there were any issues with the unfolding of the intraocular lens or its placement into the capsular bag. |
Intraoperative
|
その他の成果指標
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Serious Adverse Events
時間枠:1 month postoperatively
|
Any serious adverse events occurring during surgery or within 1 month after surgery. |
1 month postoperatively
|
|
Postoperative Inflammation
時間枠:1 week and 1 month postoperatively
|
Assessment of inflammation levels by biomicroscopic anterior chamber and vitreus examination according to Standardization of Uveitis Nomenclature (SUN) International Workshop Grading System |
1 week and 1 month postoperatively
|
|
Intraocular Pressure,
時間枠:1 week and 1 month postoperatively
|
Intraocular pressure is assessed via Goldmann Applanation Tonometry. Normal levels are accepted as 10-21 mmHG. |
1 week and 1 month postoperatively
|
協力者と研究者
出版物と役立つリンク
一般刊行物
- Oshika T, Wolfe P. In vitro comparison of delivery performance of 4 preloaded intraocular lens injector systems for corneal and sclerocorneal incisions. J Cataract Refract Surg. 2019 Jun;45(6):840-846. doi: 10.1016/j.jcrs.2018.10.050. Epub 2019 Mar 8.
- Joshi RS. Comparative evaluation of an automated preloaded delivery system with a non-preloaded system. Indian J Ophthalmol. 2022 Dec;70(12):4307-4311. doi: 10.4103/ijo.IJO_1635_22.
- Acar B, Torun IM, Acar S. Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery. Open Ophthalmol J. 2018 Jun 14;12:94-103. doi: 10.2174/1874364101812010094. eCollection 2018.
研究記録日
主要日程の研究
研究開始 (実際)
研究開始
一次修了 (実際)
一次修了
研究の完了 (実際)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
その他の研究ID番号
- IstanbulUni
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
Individual participant data will not be shared outside the study.
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。