Fiabilité et efficacité du nouveau système de lentille intraoculaire et de cartouche préchargé Enova

3 novembre 2026 mis à jour par: Semih Çakmak, Istanbul University

Fiabilité et efficacité du nouveau système de lentille intraoculaire préchargée Enova et de sa cartouche

Evaluation of the safety and efficacy of the new Enova® preloaded monofocal intraocular lens and cartridge injector system in cataract surgery

Aperçu de l'étude

Statut

Complété

Les conditions

Intervention / Traitement

Description détaillée

In this prospective and single-center clinical study, the safety and efficacy of the Enova PGF3 intraocular lens (IOL) and cartridge injector system will be evaluated.

The Enova PGF3 cartridge injector system is designed to be used in cataract surgeries. Cataract patients aged 40 years and older, both male and female, without any serious ocular disease other than cataracts, will undergo IOL implantation following cataract surgery. It is planned to perform a total of 200 implantations with either unilateral or bilateral implantation of the participants' eyes.

Postoperative visual acuity, refraction, patient satisfaction, and adverse events will be monitored during follow-up visits at day 1, week 1, and month 1.

The primary objectives of the study are to achieve an uncorrected distance visual acuity of 20/20 or better, and to maintain an error and complication rate related to the preloaded system below 7.5%. Secondary objectives include evaluating patient satisfaction and assessing whether surgeons find the preloaded system easy to use and if it meets their expectations.

The primary endpoints are refractive stability within ±0.50 D, uncorrected distance visual acuity of 20/20 or better, and a general clinical performance rating of the preloaded system with a score of 95% or higher. Secondary endpoints include the duration of surgery, accuracy of lens positioning, surgical complications, surgeon-reported ease of use, and patient satisfaction survey results meeting expectations.

As a safety parameter, adverse events reported in postoperative surgical reports will be evaluated.

Type d'étude

Interventionnel

Inscription (Réel)

200

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Fatih
      • Istanbul, Fatih, Turquie (Türkiye), 34250
        • Istanbul University Istanbul Medical Faculty Ophthalmology Department

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

40 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Adults of either sex.

Age 40 years or older.

Willing and able to provide written informed consent and comply with planned study visits and procedures.

Healthy ocular status, with no ocular pathology other than cataract and mild refractive error.

Potential visual acuity of 20/32 (0.2 logMAR) or better in both eyes.

Presence of regular corneal astigmatism suitable for treatment with the study device.

Candidates for uncomplicated cataract surgery using the study device.

Exclusion Criteria:

  • Irregular corneal astigmatism (e.g., keratoconus).

Corneal pathology (e.g., scar, dystrophy, pterygium, moderate to severe dry eye).

Monocular conditions (e.g., amblyopia).

Previous corneal surgery, including radial keratotomy, corneal refractive surgery, corneal transplantation, DSAEK, or lamellar keratoplasty.

Previous anterior or posterior segment surgery (e.g., vitrectomy, laser iridotomy).

Diabetic retinopathy.

Macular pathology (e.g., age-related macular degeneration [ARMD], epiretinal membrane [ERM]).

History of retinal detachment.

Surgical complications that may affect study outcomes, such as:

Decentration due to capsulorhexis issues

Improper lens placement

Inadequate or missing postoperative capsular support

Posterior capsular rupture

Vitreous loss

Iris damage (tear, rupture, etc.)

Acute or chronic ocular diseases known to affect visual acuity or study outcomes (e.g., immunosuppressed state, connective tissue disease, clinically significant atopic disease, diabetes, or other systemic or ocular conditions).

Participation in any investigational drug or device study within 30 days prior to study start, or ongoing participation in another study.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: N / A
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Patients who need cataract surgery

Participants will undergo standard cataract surgery using the new preloaded intraocular lens (IOL) system. The intervention involves implantation of the preloaded IOL following routine phacoemulsification techniques.

This intervention uses a preloaded IOL delivery system, which allows for a single-use, sterile implantation during standard phacoemulsification cataract surgery. Unlike standard manually loaded IOLs, this system reduces preparation time and minimizes handling of the lens, potentially improving surgical efficiency and maintaining lens sterility.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Uncorrected Distance Visual Acuity (UDVA) - Photopic Conditions
Délai: 1 month postoperatively

Proportion of eyes achieving 20/20 or better uncorrected distance visual acuity under photopic conditions.

1 month postoperatively
Subjective Refractive Error
Délai: 1 month postoperatively

Eyes with a postoperative refractive error within ±0.50 diopters of the intended target.

1 month postoperatively
Overall Clinical Performance of the Preloaded IOL System
Délai: 1 month after surgery

Surgeon-rated assessment of the general clinical performance of the preloaded system by The ENOVA PGF3 Questionnaire. This questionnaire is a 14-item, study-specific, non-validated survey developed to evaluate surgeons' experience with an intraocular lens (IOL) preloaded delivery system. Eleven items are rated on a 5-point Likert scale with the following scoring structure:

  1. = Low
  2. = Below Expectation
  3. = Meets Expectation
  4. = Above Expectation
  5. = Outstanding Performance

Some additional items are Yes/No questions and do not contribute to the numerical total score.

The total numerical score is calculated by summing the 11 Likert-scaled items. Total score range: 11 to 55, with higher scores indicating better performance and more favorable user experience.

1 month after surgery

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Preloaded System Evaluation Patient Questionnaire
Délai: Baseline (preoperative) and 1 month postoperatively

Patient-reported outcomes assessing whether expectations for visual improvement and overall satisfaction were met.The questionnaire consists of 14 items assessing a patient's self-reported difficulty in performing vision-related daily activities. Each activity is rated using a 0-4 scale, where:

4 = No difficulty

3 = Mild difficulty

2 = Moderate difficulty

1 = Severe difficulty

0 = Unable to perform the activity

The total score is calculated by summing responses across all 14 items. Total possible score range: 0 to 56

Higher scores indicate better visual function and less activity limitation.

Lower scores indicate worse visual function.

Baseline (preoperative) and 1 month postoperatively
Surgical Procedure Assessment
Délai: Intraoperative

Surgeon-reported ease of lens implantation and accuracy of lens placement, evaluating whether expectations for procedural handling were met.The surgeon notes, during the operative visit, the location of the incision, the size of the incision, whether the implantation system is compatible with the wound site, how many seconds the implantation time is shortened, and whether there were any issues with the unfolding of the intraocular lens or its placement into the capsular bag.

Intraoperative

Autres mesures de résultats

Mesure des résultats
Description de la mesure
Délai
Serious Adverse Events
Délai: 1 month postoperatively

Any serious adverse events occurring during surgery or within 1 month after surgery.

1 month postoperatively
Postoperative Inflammation
Délai: 1 week and 1 month postoperatively

Assessment of inflammation levels by biomicroscopic anterior chamber and vitreus examination according to Standardization of Uveitis Nomenclature (SUN) International Workshop Grading System

1 week and 1 month postoperatively
Intraocular Pressure,
Délai: 1 week and 1 month postoperatively

Intraocular pressure is assessed via Goldmann Applanation Tonometry. Normal levels are accepted as 10-21 mmHG.

1 week and 1 month postoperatively

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

10 mai 2025

Achèvement primaire (Réel)

1 juin 2026

Achèvement de l'étude (Réel)

1 juillet 2026

Dates d'inscription aux études

Première soumission

26 août 2025

Première soumission répondant aux critères de contrôle qualité

3 décembre 2025

Première publication (Réel)

17 décembre 2025

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

4 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

3 novembre 2026

Dernière vérification

1 novembre 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • IstanbulUni

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

INDÉCIS

Description du régime IPD

Individual participant data will not be shared outside the study.

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .