Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Fiabilidad y Eficacia del Nuevo Sistema de Lente Intraocular y Cartucho Precargado Enova

3 de noviembre de 2026 actualizado por: Semih Çakmak, Istanbul University

Evaluation of the safety and efficacy of the new Enova® preloaded monofocal intraocular lens and cartridge injector system in cataract surgery

Descripción general del estudio

Estado

Terminado

Condiciones

Intervención / Tratamiento

Descripción detallada

In this prospective and single-center clinical study, the safety and efficacy of the Enova PGF3 intraocular lens (IOL) and cartridge injector system will be evaluated.

The Enova PGF3 cartridge injector system is designed to be used in cataract surgeries. Cataract patients aged 40 years and older, both male and female, without any serious ocular disease other than cataracts, will undergo IOL implantation following cataract surgery. It is planned to perform a total of 200 implantations with either unilateral or bilateral implantation of the participants' eyes.

Postoperative visual acuity, refraction, patient satisfaction, and adverse events will be monitored during follow-up visits at day 1, week 1, and month 1.

The primary objectives of the study are to achieve an uncorrected distance visual acuity of 20/20 or better, and to maintain an error and complication rate related to the preloaded system below 7.5%. Secondary objectives include evaluating patient satisfaction and assessing whether surgeons find the preloaded system easy to use and if it meets their expectations.

The primary endpoints are refractive stability within ±0.50 D, uncorrected distance visual acuity of 20/20 or better, and a general clinical performance rating of the preloaded system with a score of 95% or higher. Secondary endpoints include the duration of surgery, accuracy of lens positioning, surgical complications, surgeon-reported ease of use, and patient satisfaction survey results meeting expectations.

As a safety parameter, adverse events reported in postoperative surgical reports will be evaluated.

Tipo de estudio

Intervencionista

Inscripción (Actual)

200

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Fatih
      • Istanbul, Fatih, Turquía (Türkiye), 34250
        • Istanbul University Istanbul Medical Faculty Ophthalmology Department

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

40 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Adults of either sex.

Age 40 years or older.

Willing and able to provide written informed consent and comply with planned study visits and procedures.

Healthy ocular status, with no ocular pathology other than cataract and mild refractive error.

Potential visual acuity of 20/32 (0.2 logMAR) or better in both eyes.

Presence of regular corneal astigmatism suitable for treatment with the study device.

Candidates for uncomplicated cataract surgery using the study device.

Exclusion Criteria:

  • Irregular corneal astigmatism (e.g., keratoconus).

Corneal pathology (e.g., scar, dystrophy, pterygium, moderate to severe dry eye).

Monocular conditions (e.g., amblyopia).

Previous corneal surgery, including radial keratotomy, corneal refractive surgery, corneal transplantation, DSAEK, or lamellar keratoplasty.

Previous anterior or posterior segment surgery (e.g., vitrectomy, laser iridotomy).

Diabetic retinopathy.

Macular pathology (e.g., age-related macular degeneration [ARMD], epiretinal membrane [ERM]).

History of retinal detachment.

Surgical complications that may affect study outcomes, such as:

Decentration due to capsulorhexis issues

Improper lens placement

Inadequate or missing postoperative capsular support

Posterior capsular rupture

Vitreous loss

Iris damage (tear, rupture, etc.)

Acute or chronic ocular diseases known to affect visual acuity or study outcomes (e.g., immunosuppressed state, connective tissue disease, clinically significant atopic disease, diabetes, or other systemic or ocular conditions).

Participation in any investigational drug or device study within 30 days prior to study start, or ongoing participation in another study.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Patients who need cataract surgery

Participants will undergo standard cataract surgery using the new preloaded intraocular lens (IOL) system. The intervention involves implantation of the preloaded IOL following routine phacoemulsification techniques.

This intervention uses a preloaded IOL delivery system, which allows for a single-use, sterile implantation during standard phacoemulsification cataract surgery. Unlike standard manually loaded IOLs, this system reduces preparation time and minimizes handling of the lens, potentially improving surgical efficiency and maintaining lens sterility.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Uncorrected Distance Visual Acuity (UDVA) - Photopic Conditions
Periodo de tiempo: 1 month postoperatively

Proportion of eyes achieving 20/20 or better uncorrected distance visual acuity under photopic conditions.

1 month postoperatively
Subjective Refractive Error
Periodo de tiempo: 1 month postoperatively

Eyes with a postoperative refractive error within ±0.50 diopters of the intended target.

1 month postoperatively
Overall Clinical Performance of the Preloaded IOL System
Periodo de tiempo: 1 month after surgery

Surgeon-rated assessment of the general clinical performance of the preloaded system by The ENOVA PGF3 Questionnaire. This questionnaire is a 14-item, study-specific, non-validated survey developed to evaluate surgeons' experience with an intraocular lens (IOL) preloaded delivery system. Eleven items are rated on a 5-point Likert scale with the following scoring structure:

  1. = Low
  2. = Below Expectation
  3. = Meets Expectation
  4. = Above Expectation
  5. = Outstanding Performance

Some additional items are Yes/No questions and do not contribute to the numerical total score.

The total numerical score is calculated by summing the 11 Likert-scaled items. Total score range: 11 to 55, with higher scores indicating better performance and more favorable user experience.

1 month after surgery

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Preloaded System Evaluation Patient Questionnaire
Periodo de tiempo: Baseline (preoperative) and 1 month postoperatively

Patient-reported outcomes assessing whether expectations for visual improvement and overall satisfaction were met.The questionnaire consists of 14 items assessing a patient's self-reported difficulty in performing vision-related daily activities. Each activity is rated using a 0-4 scale, where:

4 = No difficulty

3 = Mild difficulty

2 = Moderate difficulty

1 = Severe difficulty

0 = Unable to perform the activity

The total score is calculated by summing responses across all 14 items. Total possible score range: 0 to 56

Higher scores indicate better visual function and less activity limitation.

Lower scores indicate worse visual function.

Baseline (preoperative) and 1 month postoperatively
Surgical Procedure Assessment
Periodo de tiempo: Intraoperative

Surgeon-reported ease of lens implantation and accuracy of lens placement, evaluating whether expectations for procedural handling were met.The surgeon notes, during the operative visit, the location of the incision, the size of the incision, whether the implantation system is compatible with the wound site, how many seconds the implantation time is shortened, and whether there were any issues with the unfolding of the intraocular lens or its placement into the capsular bag.

Intraoperative

Otras medidas de resultado

Medida de resultado
Medida Descripción
Periodo de tiempo
Serious Adverse Events
Periodo de tiempo: 1 month postoperatively

Any serious adverse events occurring during surgery or within 1 month after surgery.

1 month postoperatively
Postoperative Inflammation
Periodo de tiempo: 1 week and 1 month postoperatively

Assessment of inflammation levels by biomicroscopic anterior chamber and vitreus examination according to Standardization of Uveitis Nomenclature (SUN) International Workshop Grading System

1 week and 1 month postoperatively
Intraocular Pressure,
Periodo de tiempo: 1 week and 1 month postoperatively

Intraocular pressure is assessed via Goldmann Applanation Tonometry. Normal levels are accepted as 10-21 mmHG.

1 week and 1 month postoperatively

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

10 de mayo de 2025

Finalización primaria (Actual)

1 de junio de 2026

Finalización del estudio (Actual)

1 de julio de 2026

Fechas de registro del estudio

Enviado por primera vez

26 de agosto de 2025

Primero enviado que cumplió con los criterios de control de calidad

3 de diciembre de 2025

Publicado por primera vez (Actual)

17 de diciembre de 2025

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

4 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

3 de noviembre de 2026

Última verificación

1 de noviembre de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • IstanbulUni

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Descripción del plan IPD

Individual participant data will not be shared outside the study.

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .