IntraLase vs Hansatome Flaps in LASIK
Comparison of the IntraLaser Femtosecond Laser and Hansatome Mechanical Keratome for Laser In Situ Keratomileusis
調査の概要
研究の種類
入学
段階
- 適用できない
連絡先と場所
研究場所
-
-
California
-
Stanford、California、アメリカ、94305
- Stanford University School of Medicine
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
Inclusion criteria were "T 6.00 D of spherical myopia, "T 3.00 D of refractive astigmatism, stable refraction (less than 0.50D per year of sphere or cylinder), corneal diameter less than 11.0 mm to allow for suction fixation ring, soft contact wearer with discontinuation of wear at least 7 days prior to preoperative evaluation, visual acuity correctable to at least 20/20 in both eyes, more than 21 years of age, ability to participate in follow-up examinations for 12 months after LASIK surgery. In order to fairly compare the visual outcomes of the two keratomes, patients were required to have closely matched eyes, in terms of refractive error. Exclusion Criteria:Exclusion criteria include rigid gas permeable contact lens wearer, severe dry eyes, severe blepharitis, anterior segment pathology (cataracts or corneal scarring or neovascularization within 1 mm of intended ablation zone), recurrent corneal erosion, severe basement membrane disease, progressive or unstable myopia or keratoconus, unstable corneal mires on central keratometry, corneal thickness in which LASIK procedure would result in less than 250 micros or remaining posterior corneal thickness below the flap postoperatively, baseline standard manifest refraction > 0.75 D more minus in sphere power, or a difference of greater than 0.50D in cylinder power compared to baseline standard cycloplegic refraction, two eyes for which the baseline standard cycloplegic refraction differ from each other more than 0.75 in sphere, 0.50 D in cylinder, or have a different type of astigmatism (i.e. with-the-rule) when the cylinder is > 0.50D, or preoperative assessment of ocular topography and/or aberrations indicates that either eye is not suitable candidate for LASIK vision correction procedure (ie forme fruste keratoconus, corneal warpage, or pellucid marginal degeneration), previous intraocular or corneal surgery, and history of herpes zoster or simplex keratitis, patients on systemic corticosteroid or immunosuppressive therapy, immunocompromised subjects or clinically significant atopic disease, connective tissue disease, or diabetes, steroid responder, macular pathology, pregnant or lactating patients, patients with sensitivity to planned study concomitant medications or patients participating in another ophthalmic drug or device clinical trial.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:なし(オープンラベル)
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
---|
視力
|
二次結果の測定
結果測定 |
---|
コントラスト感度
|
協力者と研究者
スポンサー
研究記録日
主要日程の研究
研究開始
研究の完了
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。
LASIKの臨床試験
-
Singapore National Eye CentreSingapore Armed Forces; Defence Medical Environmental Research Institute完了
-
Bismarck LasikSengi終了しました
-
The Cleveland ClinicAlcon Research完了
-
University of Texas Southwestern Medical Center引きこもった