このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

The Safety and Efficacy of Supraglottic Airway Use in Children

2015年7月27日 更新者:Narasimhan Jagannathan、Ann & Robert H Lurie Children's Hospital of Chicago
This purpose of this study is to determine the effectiveness, risk factors, and complications associated with use of supraglottic airway devices for primary airway maintenance during routine anesthesia in children.

調査の概要

詳細な説明

This study aims to understand the efficacy of supraglottic airway (SGA) use in children in a tertiary care Children's Hospital.

Observational data regarding the type of SGA, experience level of practitioner, placement technique, number of placement attempts or placement failure, device failure, and cause of any related peri-operative complications will be prospectively collected.

The data collected in this study will allow the investigators to assess the overall safety and efficacy of SGA use in various medical and surgical procedures performed under general anesthesia in children.

研究の種類

観察的

入学 (予想される)

10000

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • Illinois
      • Chicago、Illinois、アメリカ、60611
        • 募集
        • Ann & Robert H. Lurie Children's Hospital of Chicago
        • コンタクト:
        • 主任研究者:
          • Narasimhan Jagannathan, MD

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

1日~18年 (子、大人)

健康ボランティアの受け入れ

はい

受講資格のある性別

全て

サンプリング方法

非確率サンプル

調査対象母集団

Pediatric patients undergoing anesthesia with use of a supraglottic airway device as primary means of oxygenation and ventilation.

説明

Inclusion Criteria:

  • Children undergoing anesthesia with use of a supraglottic airway device as a primary means of oxygenation & ventilation

Exclusion Criteria:

  • N/A

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
介入・治療
Supraglottic Airway Device
Patients will receive a supraglottic airway device as a primary means of ventilation. The following devices may be used: LMA Unique, LMA ProSeal, LMA Supreme, LMA Flexible, Ambu Aura-I, Ambu Aura Once, Air-Q, I-Gel, or other supraglottic airway device. Choice of the device will be clinician dependent and based on the patients body weight per manufacturer guidelines
他の名前:
  • LMA スプリーム
  • LMA プロシール
  • アイジェル
  • LMA Unique
  • LMA Flexible
  • Ambu Aura-i
  • Ambu Aura Once
  • Air-Q

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Supraglottic Airway Device Failure
時間枠:participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours
Occurrence and reason for supraglottic airway device failure (ie inadequate ventilation, laryngospasm, bronchospasm, etc) will be recorded in addition to conversion to tracheal intubation
participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours

二次結果の測定

結果測定
メジャーの説明
時間枠
Ease of Placement of Supraglottic Airway Device
時間枠:participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours
Ease of placement of supraglottic airway device ranging from 1 (easy) to 4 (difficult)
participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours
Multiple Attempts to Place Supraglottic Airway Device
時間枠:participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours
change in device, placement method, and provider will be recorded
participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours
Airway Maneuvers/interventions
時間枠:participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours
the number and type of airway maneuvers performed after device placement and during maintenance will be recorded
participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours
Occurrence of Inadequate Ventilation
時間枠:participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours
cause and solution for inadequate ventilation will be recorded
participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours
Intraoperative Complications
時間枠:participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours
Time period of complication (ie during device placement, maintenance, or removal) and cause of complication (ie. dental injury, light anesthesia, regurgitation, laryngospasm, bronchospasm, aspiration, etc.) will be recorded
participants will be followed for the duration of anesthesia and after surgery, an expected average of 12 hours
Postoperative Complications
時間枠:participants will be followed for the duration of anesthesia and 24 hours postoperatively
Complications noted postoperatively relating to reflex activation of the airway, sore throat, or hoarseness
participants will be followed for the duration of anesthesia and 24 hours postoperatively

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Narasimhan Jagannathan, MD、Ann & Robert H. Lurie Children's Hospital of Chicago / Stanley Manne Research Institute

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始

2014年6月1日

一次修了 (予想される)

2015年10月1日

研究の完了 (予想される)

2015年10月1日

試験登録日

最初に提出

2014年7月25日

QC基準を満たした最初の提出物

2014年7月25日

最初の投稿 (見積もり)

2014年7月28日

学習記録の更新

投稿された最後の更新 (見積もり)

2015年7月29日

QC基準を満たした最後の更新が送信されました

2015年7月27日

最終確認日

2015年7月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • 2014-15832

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

Supraglottic Airway Deviceの臨床試験

購読する