Motor Learning and tDCS in Parkinson's Disease
The Effect of Single Session Transcranial Direct Current Stimulation on Sequential Motor Learning in Parkinson's Disease
調査の概要
詳細な説明
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Hung Hom
-
Hong Kong、Hung Hom、香港
- The Hong Kong Polytechnic University
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Right-handed (Edinburgh Handedness Inventory; ≥50)
- Cognitively capable (Montreal Cognitive Assessment (MoCA); ≥23)
- Mild to moderate Parkinson's disease severity (Hoehn and Yar disease stage 2-3)
Exclusion Criteria:
- History of stroke
- Comorbidity
- Cephalic implants
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
---|---|
アクティブコンパレータ:Anodal tDCS
Anodal electrode (35 cm2 sponge electrode) placed over C3.
Cathodal electrode (35 cm2 sponge electrode) placed over the right supraorbital area.
20 minutes of stimulation at 2 mA with a 30-second phase-in and phase-out period.
|
Transcranial electrical stimulation device. A weak direct electrical current, up to 2 mA, is passed between two electrodes placed on the scalp. Electrodes are housed in 35 cm2 sponges saturated with 4 ml of saline solution (0.9 % NaCl) per side, per pad. Stimulation is phased in with a 30 second ramp up period prior to the specified stimulation period and phased-out with a ramp down of the current following the specified stimulation period. For sham stimulation, the ramp-up and ramp-down periods are retained, but stimulation is switched off for during the specified stimulation period.
他の名前:
|
アクティブコンパレータ:Cathodal tDCS
Cathodal electrode (35 cm2 sponge electrode) placed over C3.
Anodal electrode (35 cm2 sponge electrode) placed over the right supraorbital area.
20 minutes of stimulation at 2 mA with a 30-second phase-in and phase-out period.
|
Transcranial electrical stimulation device. A weak direct electrical current, up to 2 mA, is passed between two electrodes placed on the scalp. Electrodes are housed in 35 cm2 sponges saturated with 4 ml of saline solution (0.9 % NaCl) per side, per pad. Stimulation is phased in with a 30 second ramp up period prior to the specified stimulation period and phased-out with a ramp down of the current following the specified stimulation period. For sham stimulation, the ramp-up and ramp-down periods are retained, but stimulation is switched off for during the specified stimulation period.
他の名前:
|
偽コンパレータ:Sham tDCS
Anodal electrode (35 cm2 sponge electrode) placed over C3.
Cathodal electrode (35 cm2 sponge electrode) placed over the right supraorbital area.
Stimulation was phased in for 30 seconds up to 2 mA and then switched off.
Stimulation was again phased in for 30 seconds following 20 minutes of no stimulation.
|
Transcranial electrical stimulation device. A weak direct electrical current, up to 2 mA, is passed between two electrodes placed on the scalp. Electrodes are housed in 35 cm2 sponges saturated with 4 ml of saline solution (0.9 % NaCl) per side, per pad. Stimulation is phased in with a 30 second ramp up period prior to the specified stimulation period and phased-out with a ramp down of the current following the specified stimulation period. For sham stimulation, the ramp-up and ramp-down periods are retained, but stimulation is switched off for during the specified stimulation period.
他の名前:
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
---|---|---|
Change from baseline sequential finger tapping performance
時間枠:Two assessments: Baseline / pre-intervention, and immediately post-intervention
|
A skill index reflecting the accuracy and speed of which participants perform a specified finger tapping sequence.
|
Two assessments: Baseline / pre-intervention, and immediately post-intervention
|
Change from baseline oxygenated haemoglobin response
時間枠:Two assessments: Baseline / pre-intervention, and immediately post-intervention
|
Task related changes of oxygenated haemoglobin as measured using functional near-infrared spectroscopy.
|
Two assessments: Baseline / pre-intervention, and immediately post-intervention
|
Change from baseline shape-counting error
時間枠:Two assessments: Baseline / pre-intervention, and immediately post-intervention
|
The percentage of shape counting error during dual task assessments.
Sequential finger tapping + visual shape counting task.
|
Two assessments: Baseline / pre-intervention, and immediately post-intervention
|
協力者と研究者
捜査官
- 主任研究者:Magaret Mak, Dr、The Hong Kong Polytechnic University
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。
パーキンソン病の臨床試験
-
Adelphi Values LLCBlueprint Medicines Corporation完了肥満細胞性白血病 (MCL) | 攻撃的な全身性肥満細胞症 (ASM) | SM w Assoc Clonal Hema Non-mast Cell Lineage Disease (SM-AHNMD) | くすぶり全身性肥満細胞症 (SSM) | 無痛性全身性肥満細胞症 (ISM) ISM サブグループが完全に募集されましたアメリカ
Transcranial direct current stimulationの臨床試験
-
University of North Carolina, Chapel HillNational Institute of Mental Health (NIMH)完了