Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Motor Learning and tDCS in Parkinson's Disease

24 agosto 2021 aggiornato da: The Hong Kong Polytechnic University

The Effect of Single Session Transcranial Direct Current Stimulation on Sequential Motor Learning in Parkinson's Disease

The present study sought to examine the efficacy of single session transcranial direct current stimulation applied over the primary motor cortex in people with Parkinson's disease on sequential motor learning performance.

Panoramica dello studio

Stato

Completato

Condizioni

Descrizione dettagliata

Parkinson's disease is characterised by deficits of motor control triggered by impaired basal ganglia function, such as bradykinesia and tremor. Beyond the visibly recognisable motor symptoms of Parkinson's disease, the ability to learn a sequence of movements is also compromised and poses a significant barrier to effective rehabilitation. In healthy individuals, transcranial direct current stimulation applied over the primary motor cortex during motor task practice has been shown to significantly improve motor learning compared to placebo conditions. The present study sought to examine the effect of a single session of transcranial direct current stimulation applied over the primary motor cortex in people with Parkinson's disease on sequential motor learning performance. Participants learnt two finger tapping sequences, with task difficulty indexed by sequence length, and task consolidation further examined using a dual-task paradigm. Task related cortical haemodynamic activity was recorded using functional near-infrared spectroscopy.

Tipo di studio

Interventistico

Iscrizione (Effettivo)

33

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Hung Hom
      • Hong Kong, Hung Hom, Hong Kong
        • The Hong Kong Polytechnic University

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 40 anni a 80 anni (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Right-handed (Edinburgh Handedness Inventory; ≥50)
  • Cognitively capable (Montreal Cognitive Assessment (MoCA); ≥23)
  • Mild to moderate Parkinson's disease severity (Hoehn and Yar disease stage 2-3)

Exclusion Criteria:

  • History of stroke
  • Comorbidity
  • Cephalic implants

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Doppio

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Comparatore attivo: Anodal tDCS
Anodal electrode (35 cm2 sponge electrode) placed over C3. Cathodal electrode (35 cm2 sponge electrode) placed over the right supraorbital area. 20 minutes of stimulation at 2 mA with a 30-second phase-in and phase-out period.

Transcranial electrical stimulation device. A weak direct electrical current, up to 2 mA, is passed between two electrodes placed on the scalp. Electrodes are housed in 35 cm2 sponges saturated with 4 ml of saline solution (0.9 % NaCl) per side, per pad.

Stimulation is phased in with a 30 second ramp up period prior to the specified stimulation period and phased-out with a ramp down of the current following the specified stimulation period. For sham stimulation, the ramp-up and ramp-down periods are retained, but stimulation is switched off for during the specified stimulation period.

Altri nomi:
  • tDCS
Comparatore attivo: Cathodal tDCS
Cathodal electrode (35 cm2 sponge electrode) placed over C3. Anodal electrode (35 cm2 sponge electrode) placed over the right supraorbital area. 20 minutes of stimulation at 2 mA with a 30-second phase-in and phase-out period.

Transcranial electrical stimulation device. A weak direct electrical current, up to 2 mA, is passed between two electrodes placed on the scalp. Electrodes are housed in 35 cm2 sponges saturated with 4 ml of saline solution (0.9 % NaCl) per side, per pad.

Stimulation is phased in with a 30 second ramp up period prior to the specified stimulation period and phased-out with a ramp down of the current following the specified stimulation period. For sham stimulation, the ramp-up and ramp-down periods are retained, but stimulation is switched off for during the specified stimulation period.

Altri nomi:
  • tDCS
Comparatore fittizio: Sham tDCS
Anodal electrode (35 cm2 sponge electrode) placed over C3. Cathodal electrode (35 cm2 sponge electrode) placed over the right supraorbital area. Stimulation was phased in for 30 seconds up to 2 mA and then switched off. Stimulation was again phased in for 30 seconds following 20 minutes of no stimulation.

Transcranial electrical stimulation device. A weak direct electrical current, up to 2 mA, is passed between two electrodes placed on the scalp. Electrodes are housed in 35 cm2 sponges saturated with 4 ml of saline solution (0.9 % NaCl) per side, per pad.

Stimulation is phased in with a 30 second ramp up period prior to the specified stimulation period and phased-out with a ramp down of the current following the specified stimulation period. For sham stimulation, the ramp-up and ramp-down periods are retained, but stimulation is switched off for during the specified stimulation period.

Altri nomi:
  • tDCS

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Change from baseline sequential finger tapping performance
Lasso di tempo: Two assessments: Baseline / pre-intervention, and immediately post-intervention
A skill index reflecting the accuracy and speed of which participants perform a specified finger tapping sequence.
Two assessments: Baseline / pre-intervention, and immediately post-intervention
Change from baseline oxygenated haemoglobin response
Lasso di tempo: Two assessments: Baseline / pre-intervention, and immediately post-intervention
Task related changes of oxygenated haemoglobin as measured using functional near-infrared spectroscopy.
Two assessments: Baseline / pre-intervention, and immediately post-intervention
Change from baseline shape-counting error
Lasso di tempo: Two assessments: Baseline / pre-intervention, and immediately post-intervention
The percentage of shape counting error during dual task assessments. Sequential finger tapping + visual shape counting task.
Two assessments: Baseline / pre-intervention, and immediately post-intervention

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Magaret Mak, Dr, The Hong Kong Polytechnic University

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

7 gennaio 2019

Completamento primario (Effettivo)

27 settembre 2019

Completamento dello studio (Effettivo)

27 settembre 2019

Date di iscrizione allo studio

Primo inviato

1 marzo 2021

Primo inviato che soddisfa i criteri di controllo qualità

5 marzo 2021

Primo Inserito (Effettivo)

8 marzo 2021

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

26 agosto 2021

Ultimo aggiornamento inviato che soddisfa i criteri QC

24 agosto 2021

Ultimo verificato

1 febbraio 2021

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

No

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Morbo di Parkinson

Prove cliniche su Transcranial direct current stimulation

Sottoscrivi