このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

2 つの異なる酸素濃度計を使用した 2 つの酸素化ターゲットの比較 - 酸素流量と酸素化への影響 (Oxygap pong)

2026年11月3日 更新者:François Lellouche、Laval University

The investigators recently evaluated 4 different oximeters among the most commonly used with arterial catheter in place and compared SpO2 with SaO2 obtained on arterial gas. Correlations between SaO2 and SpO2 were poor for all oximeters, as previously known, and SpO2-SaO2 bias were different between oximeters. Some oximeters (Masimo, Nellcor) had lower biases but they detected less well hypoxemia. Some oximeters underestimated SaO2 (Nonin) but detected very well hypoxemia, and some overestimated SaO2 (Philips). The investigators concluded that oximeters provide different informations to clinicians, and oxygenation targets should take into account for these differences.

The assumption is that the SpO2 target AND oximeter used will both have an impact on oxygen flows and that these effects will add up. With a high SpO2 target, oxygen flows will be significantly greater and with the Nonin oximeter, the required flows will be greater than with the Philips oximeter.

NB: the results obtained were in a population with light skin pigmentation (96% of the patients were Fitzpatrick 1-2, reflecting the local hospitalized population).

調査の概要

詳細な説明

The oximeters to be evaluated will be the Nonin (Plymouth, MN), and the Philips (Eindhoven, Netherlands). The sensors used will be digital reusable sensors for all oximeters. Because of the impact of the fingers used for SpO2 measurement, each oximeter will be randomly assigned a different finger to each patient (digit 2 and 3 on the hand opposite to the arterial catheter).

Two SpO2 targets will be assessed: 90% and 94%. A total of four 10-minute periods will be performed in randomized order: Nonin 90, Nonin 94, Philips 90, and Philips 94.

At the end of each 10-minute period, arterial gas will be collected through the arterial catheter.

The adjustment of the oxygen flow rates will be performed manually. The average oxygen flow of the last 2 minutes of the period will be considered.

研究の種類

介入

入学 (推定)

40

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究連絡先のバックアップ

研究場所

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • ≥ 18 years of age
  • Patients admitted to postoperative cardiac surgery intensive care unit
  • Presence of an arterial catheter Specific for the extubate patient
  • Ongoing on conventional oxygen therapy at moderate flow (up to a maximum of 5L/min) with SpO2 between 88 and 100% with the usual oximeter and nasal cannula.
  • SpO2 < 92% ambient air Specific for the intubate patient FiO2 <= 0.60 with SpO2 between 88 and 100% with usual oximeter SpO2 < 92% with FiO2 0.21

Exclusion Criteria:

  • No SpO2 signal with oximeter in use
  • False nails or nail polish
  • Methemoglobinemia >0.015 on last available arterial gas
  • Patient in isolation (multi-resistant bacteria, C-Difficile, SARS-CoV-2 ...) Specific for the extubate patient
  • Expected to use another respiratory support within one hour of inclusion (NIV or nasal high flow oxygen) Planned extubation within one hour of inclusion

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:クロスオーバー割り当て
  • マスキング:独身

武器と介入

参加者グループ / アーム
介入・治療
実験的:Nonin oximeter with a 90% SpO2 target

During this periods , oxygen will be administered in an manual titration with the FreeO2 device (fixed flow mode) to reach 90% of SpO2.

Oxygen titration with FreeO2 device (fixed flow mode) to reach the SpO2 target (set at 90%) with Nonin oximeter

実験的:Philips oximeter with a 90% SpO2 target

During this periods, oxygen will be administered in a manual titration with the FreeO2 device (fixed flow mode), to reach 90% of SpO2.

Oxygen titration with FreeO2 device (fixed flow mode) to reach the SpO2 target (set at 90%) with Philips oximeter

実験的:Nonin oximeter with a 94% SpO2 target

During this periods , oxygen will be administered in a manual titration with the FreeO2 device (fixed flow mode) to reach 94% of SpO2.

Oxygen titration with FreeO2 device (fixed flow mode) to reach the SpO2 target (set at 94%) with Philips oximeter

実験的:Philips oximeter with a 94% SpO2 target

During this periods, oxygen will be administered in a manual titration with the FreeO2 device (fixed flow mode), to reach 94% of SpO2.

Oxygen titration with FreeO2 device (fixed flow mode) to reach the SpO2 target (set at 94%) with Philips oximeter

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Oxygen flow (or FiO2)
時間枠:Mean Oxygen flow in the two last minute of each study period (between minute 8 and 10)

Oxygen flows (or FiO2) at the end of each study period (last minute average) to reach SpO2 target to reach SpO2 target with specific oximeter

Mean Oxygen flow in the two last minute of each study period (between minute 8 and 10)

二次結果の測定

結果測定
メジャーの説明
時間枠
Difference between SpO2 and SaO2
時間枠:assessed up to 10 minutes - at the same of the arterial blood gases punction

Difference (%) between SpO2 from each oximeter and SaO2 (% of SaO2 overestimation and underestimation for each oximeter)

assessed up to 10 minutes - at the same of the arterial blood gases punction

その他の成果指標

結果測定
メジャーの説明
時間枠
Mean difference on oxymeter
時間枠:assessed up to 10 minutes - at the same of the arterial blood gases punction

Mean (±SD) of the gaps between the different oximeters tested

assessed up to 10 minutes - at the same of the arterial blood gases punction
Occult hypoxemia
時間枠:assessed up to 10 minutes - at the same of the arterial blood gases punction

Percentage of occult hypoxemia (SaO2<90% and SpO2>=90%)

assessed up to 10 minutes - at the same of the arterial blood gases punction
Occult hyperoxemia
時間枠:assessed up to 10 minutes - at the same of the arterial blood gases punction

Perrcentage of occult hyperoxemia (SaO2>96% and SpO2<=96%)

assessed up to 10 minutes - at the same of the arterial blood gases punction
Partial oxygen weaning
時間枠:Mean oxygen flow in the two last minute of each study period (between minute 8 and 10)

Rate of partial oxygen weaning (Oxygen flow <=0.5 L/min)

Mean oxygen flow in the two last minute of each study period (between minute 8 and 10)
Complete oxygen weaning
時間枠:Mean oxygen flow in the two last minute of each study period (between minute 8 and 10)

Rate of complete oxygen weaning (Oxygen flow =0 L/min or FiO2 0.21)

Mean oxygen flow in the two last minute of each study period (between minute 8 and 10)
Respiratory support escalation
時間枠:Mean oxygen flow in the two last minute of each study period (between minute 8 and 10)

Indication of initiation of respiratory support escalation (Oxygen flow >6 L/min or FiO2 > 0.60)

Mean oxygen flow in the two last minute of each study period (between minute 8 and 10)

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2022年11月16日

一次修了 (推定)

2027年6月1日

研究の完了 (推定)

2027年12月1日

試験登録日

最初に提出

2022年10月14日

QC基準を満たした最初の提出物

2022年10月18日

最初の投稿 (実際)

2022年10月21日

学習記録の更新

投稿された最後の更新 (実際)

2026年11月5日

QC基準を満たした最後の更新が送信されました

2026年11月3日

最終確認日

2026年11月1日

詳しくは

本研究に関する用語

追加の関連 MeSH 用語

その他の研究ID番号

  • 22266

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する