- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT01061931
Mesh Ablator Versus Cryoballoon Pulmonary Vein Ablation of Symptomatic Paroxysmal Atrial Fibrillation (MACPAF)
2014년 6월 23일 업데이트: Jochen B. Fiebach, Charite University, Berlin, Germany
HD Mesh Ablator Versus Cryoballoon Pulmonary Vein Ablation of Symptomatic Paroxysmal Atrial Fibrillation - Efficiency and Safety of PV Ablation Systems
The purpose of this prospective randomized single-center trial is to compare efficiency and safety of two pulmonary vein ablation systems in patients with symptomatic paroxysmal atrial fibrillation using the Arctic Front® versus the HD Mesh Ablator® catheter.
연구 개요
상태
종료됨
상세 설명
Primary objective:
• Efficacy of pulmonary vein isolation defined by achieving an exit block for all pulmonary veins per patient.
Secondary objectives:
- Detecting (silent) cerebral thromboembolism using neuro(psychological) tests and brain MRI prior and within 2 days after PV ablation.
- Detecting (silent) cerebral thromboembolism using neuro(psychological) tests and brain MRI within 6 months after PV ablation.
- Determination of spontaneous recurrence rate of atrial fibrillation using a subcutaneously implanted loop recorder (Reveal XT®).
- Characterization of non-neurological major complications (death, atrial-esophageal fistula, pulmonary vein stenosis, pericardial tamponade)
- Rate of iatrogenic interatrial septal defects after transseptal puncture for PV ablation.
연구 유형
중재적
등록 (예상)
108
단계
- 4단계
연락처 및 위치
이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.
연구 장소
-
-
-
Berlin, 독일, 12200
- Charité, University Medicine Berlin, Campus Benjamin Franklin, Hindenburgdamm 30
-
-
참여기준
연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.
자격 기준
공부할 수 있는 나이
18년 (성인, 고령자)
건강한 자원 봉사자를 받아들입니다
아니
연구 대상 성별
모두
설명
Inclusion Criteria:
- Patients with ECG-documented symptomatic paroxysmal atrial fibrillation and at least one ineffective antiarrhythmic drug treatment
Exclusion Criteria:
- Previous ablation procedure for atrial fibrillation or cardiac surgery within 3 months
- Left atrial diameter > 50mm or ejection fraction < 35%
- Instable coronary artery disease or clinically relevant cardiac valve insufficiency
- Hyperthyroidism, pregnancy or lactation; coumadin or heparin intolerance
- Concomitant disease with expected lifespan < 2 years
- Contraindications for MRI or acute cerebral infarction detected by brain MRI immediately (< 24 hours) before catheter ablation.
공부 계획
이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 하나의
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
---|---|
활성 비교기: Arctic Front® catheter
|
Pulmonary vein ablation in patients with symptomatic paroxysmal atrial fibrillation using the Arctic Front® catheter versus the HD Mesh Ablator® catheter
|
활성 비교기: HD Mesh Ablator® catheter
|
Pulmonary vein ablation in patients with symptomatic paroxysmal atrial fibrillation using the Arctic Front® catheter versus the HD Mesh Ablator® catheter
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
기간 |
---|---|
Efficacy of pulmonary vein isolation defined by achieving an exit block for all pulmonary veins per patient
기간: During ablation procedure
|
During ablation procedure
|
2차 결과 측정
결과 측정 |
기간 |
---|---|
Detecting (silent) cerebral thromboembolism using neuro(psychological) tests and brain MRI
기간: within 2 days after catheter ablation
|
within 2 days after catheter ablation
|
Detecting (silent) cerebral thromboembolism using neuro(psychological) tests and brain MRI
기간: 6 months after catheter ablation
|
6 months after catheter ablation
|
Determination of spontaneous recurrence rate of atrial fibrillation using a subcutaneously implanted loop recorder (Reveal XT®)
기간: 1 year after catheter ablation
|
1 year after catheter ablation
|
Characterization of non-neurologic major complications (death, atrial-esophageal fistula, pulmonary vein stenosis, pericardial tamponade)
기간: within 1 month after catheter ablation
|
within 1 month after catheter ablation
|
Rate of iatrogenic interatrial septal defects after transseptal puncture for left-sided atrial catheter ablation
기간: 1 year after catheter ablation
|
1 year after catheter ablation
|
공동 작업자 및 조사자
여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.
수사관
- 수석 연구원: Alexander Schirdewan, MD, Department of Cardiology, Charité - University Medicine Berlin, Germany.
- 수석 연구원: Jochen B Fiebach, MD, Center for Stroke Research Berlin
간행물 및 유용한 링크
연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.
일반 간행물
- Herm J, Schirdewan A, Koch L, Wutzler A, Fiebach JB, Endres M, Kopp UA, Haeusler KG. Impact of atrial fibrillation burden on cognitive function after left atrial ablation - Results of the MACPAF study. J Clin Neurosci. 2020 Mar;73:168-172. doi: 10.1016/j.jocn.2019.12.030. Epub 2020 Jan 25.
- Schirdewan A, Herm J, Roser M, Landmesser U, Endres M, Koch L, Haeusler KG. Loop Recorder Detected High Rate of Atrial Fibrillation Recurrence after a Single Balloon- or Basket-Based Ablation of Paroxysmal Atrial Fibrillation: Results of the MACPAF Study. Front Cardiovasc Med. 2017 Feb 13;4:4. doi: 10.3389/fcvm.2017.00004. eCollection 2017.
- Herm J, Fiebach JB, Koch L, Kopp UA, Kunze C, Wollboldt C, Brunecker P, Schultheiss HP, Schirdewan A, Endres M, Haeusler KG. Neuropsychological effects of MRI-detected brain lesions after left atrial catheter ablation for atrial fibrillation: long-term results of the MACPAF study. Circ Arrhythm Electrophysiol. 2013 Oct;6(5):843-50. doi: 10.1161/CIRCEP.113.000174. Epub 2013 Aug 29.
- Haeusler KG, Koch L, Herm J, Kopp UA, Heuschmann PU, Endres M, Schultheiss HP, Schirdewan A, Fiebach JB. 3 Tesla MRI-detected brain lesions after pulmonary vein isolation for atrial fibrillation: results of the MACPAF study. J Cardiovasc Electrophysiol. 2013 Jan;24(1):14-21. doi: 10.1111/j.1540-8167.2012.02420.x. Epub 2012 Aug 22.
- Koch L, Haeusler KG, Herm J, Safak E, Fischer R, Malzahn U, Werncke T, Heuschmann PU, Endres M, Fiebach JB, Schultheiss HP, Schirdewan A. Mesh ablator vs. cryoballoon pulmonary vein ablation of symptomatic paroxysmal atrial fibrillation: results of the MACPAF study. Europace. 2012 Oct;14(10):1441-9. doi: 10.1093/europace/eus084. Epub 2012 Apr 20.
- Haeusler KG, Koch L, Ueberreiter J, Coban N, Safak E, Kunze C, Villringer K, Endres M, Schultheiss HP, Fiebach JB, Schirdewan A. Safety and reliability of the insertable Reveal XT recorder in patients undergoing 3 Tesla brain magnetic resonance imaging. Heart Rhythm. 2011 Mar;8(3):373-6. doi: 10.1016/j.hrthm.2010.11.008. Epub 2010 Nov 9.
- Haeusler KG, Koch L, Ueberreiter J, Endres M, Schultheiss HP, Heuschmann PU, Schirdewan A, Fiebach JB. Stroke risk associated with balloon based catheter ablation for atrial fibrillation: Rationale and design of the MACPAF Study. BMC Neurol. 2010 Jul 21;10:63. doi: 10.1186/1471-2377-10-63.
연구 기록 날짜
이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.
연구 주요 날짜
연구 시작
2009년 3월 1일
기본 완료 (실제)
2010년 11월 1일
연구 완료 (실제)
2011년 11월 1일
연구 등록 날짜
최초 제출
2010년 2월 2일
QC 기준을 충족하는 최초 제출
2010년 2월 2일
처음 게시됨 (추정)
2010년 2월 3일
연구 기록 업데이트
마지막 업데이트 게시됨 (추정)
2014년 6월 24일
QC 기준을 충족하는 마지막 업데이트 제출
2014년 6월 23일
마지막으로 확인됨
2014년 6월 1일
추가 정보
이 연구와 관련된 용어
키워드
기타 연구 ID 번호
- MACPAF
- 4-087-08 (기타 식별자: ethic's committee Charité Berlin)
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .