Supine Photon-Counting CT and Contrast-Enhanced Mammography Versus Breast MRI for Pretreatment Tumor Size in Breast Cancer Candidates for Neoadjuvant Chemotherapy (PC CEM MRI)
Retrospective single-centre agreement study in women with biopsy-proven invasive breast cancer who underwent CEM, supine PC-CT and prone breast MRI before neoadjuvant chemotherapy. Prone MRI is the clinical reference.
연구 개요
상태
상세 설명
Breast MRI is the reference imaging test for locoregional staging but is not available to every patient before NAC. PC-CT performed for systemic staging also images both breasts and axillae. Consecutive women who underwent CEM, supine PC-CT and breast MRI before the first NAC cycle were analyzed. Two breast radiologists reviewed each modality in separate sessions. Because all patients received NAC, surgical pathology could not serve as reference for pretreatment size, so prone dynamic MRI was used as the clinical reference and the study was designed as an agreement study, not a diagnostic accuracy study
연구 유형
등록 (실제)
연락처 및 위치
연구 장소
-
-
Italy
-
Sassari, Italy, 이탈리아, 07100
- Aou Sassari
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
샘플링 방법
연구 인구
Consecutive women with biopsy-proven invasive breast cancer referred for NAC to the Department of Radiological, Interventional and Emergency Sciences, Azienda Ospedaliero-Universitaria di Sassari, Italy, between April 2025 and June 2026.
설명
Inclusion Criteria: (a) invasive carcinoma at core needle or vacuum-assisted biopsy; (b) indication for NAC by the multidisciplinary tumor board; (c) CEM, supine PC-CT and breast MRI all performed before NAC.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 관찰 모델: COHORT
- 시간 관점: RETROSPECTIVE
코호트 및 개입
그룹/코호트 |
개입 / 치료 |
|---|---|
|
NAC candidates with three imaging examinations
Women with biopsy-proven invasive breast cancer and indication for NAC who underwent all three examinations before the first NAC cycle. |
Clinically indicated contrast-enhanced oncologic staging CT of chest and abdomen, performed in the supine position on a dual-source photon-counting detector CT scanner (NAEOTOM Alpha, Siemens Healthineers). Iodinated contrast medium (370 mg I/mL; 1.2 mL/kg) at 3.5 mL/s, acquisition at a fixed delay of 65-70 s. Breast assessment used the chest portion of the acquisition, with no additional radiation exposure or contrast administration. 40-keV and 60-keV virtual monoenergetic images and iodine maps were reconstructed. Performed in the prone position on a 1.5-T scanner (MAGNETOM Altea, Siemens Healthineers) with a dedicated breast coil, including T2-weighted and multiphase T1-weighted sequences before and after gadolinium-based contrast administration. Used as the clinical reference for tumor size. CEM was performed immediately after the staging PC-CT, using the same contrast bolus, without a second injection; low- and high-energy craniocaudal and mediolateral oblique views were acquired within 6 minutes of the end of the PC-CT acquisition. |
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Agreement in maximum tumor diameter between supine PC-CT and prone MRI
기간: before the first NAC cycle (April 2025 to June 2026)
|
Bland-Altman mean bias and 95% limits of agreement, and intraclass correlation coefficient, of the maximum diameter of the index cancer. |
before the first NAC cycle (April 2025 to June 2026)
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
CEM vs MRI e PC-CT vs CEM
기간: before the first NAC cycle.
|
Proportion of measurements within ±5 mm and ±20% of MRI size |
before the first NAC cycle.
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
키워드
기타 연구 ID 번호
- T_2_2025
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .