CT for Pulmonary Thromboembolic Disease (CT for PE)
Individually Optimized Uniform Contrast Enhancement in CT Angiography for the Diagnosis of Pulmonary Thromboembolic Disease
Studie Overzicht
Toestand
Conditie
Gedetailleerde beschrijving
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
Maryland
-
Baltimore, Maryland, Verenigde Staten, 21201
- University of Maryland Medical Center
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Patients 18 years old or older
- Patients who have been recommended for CTPA scan for the diagnosis of pulmonary; thromboembolic disease (PE) in the Department of Diagnostic Radiology and Nuclear Medicine at the University of Maryland-Patients whose body mass index (BMI) is greater than 30 kg/m2.
- Patients whose body mass index (BMI) is greater than 30 kg/m2
- Patients who signed the University of Maryland Medical Center Consent for Intravenous Contrast Administration
Exclusion Criteria:
- Pregnant or breast-feeding women; Female participants of childbearing age (10 - 60 years) will be screened for their pregnancy status prior to study registration, by following the Department of Diagnostic Radiology and Nuclear Medicine CLINICAL STANDARD Procedure DI-AOP-003 "Pregnancy Screening Documentation"; - Patients with decreased renal function34-36. This is evaluated by blood work checked within 30 days prior to the CTPA scan with contrast. Patients cannot receive contrast if their BUN index is not within [7-20] or creatinine is not within [0.5 - 1.4] mg/dL
- Patients with decreased renal function34-36. This is evaluated by blood work checked within current admission for inpatients or within 30 days for outpatients prior to the CTPA scan with contrast. Patients cannot receive contrast if their serum creatinine level exceeds 2.0 mg/dL
- Patients with known moderate or severe allergic reactions to contrast, including but not limited to: shortness of breath, a change in baseline vital signs, such as a change in blood pressure, tachycardia, increased respirations that can progress to major respiratory distress, laryngeal edema, bronchospasm, arrhythmias, convulsions, and cardiopulmonary arrest.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
---|
Prospective
Twenty patients will be enrolled and scanned with the RESEARCH procedures
|
Retrospective
Patients with matching age and BMI will be selected from existing patients with a CLINICAL STANDARD of Care CTPA scan.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
---|---|---|
Feasibility of patients with individually optimized bi-phasic contrast injection for CTPA scan
Tijdsspanne: 1 year
|
The primary endpoint is to study the feasibility( bi-phasic vs. singular pahse contrast injection (by comparison analysis)) of individually optimized bi-phasic contrast injection for CTPA scan.
|
1 year
|
Efficacy of PE diagnosis with CTPA imaging
Tijdsspanne: 1 year
|
To quantify the efficacy (by comparison analysis) of PE diagnosis of this new contrast injection protocol in terms of reduced frequency of non-diagnostic CTPA image vs. standard of care procedures.
|
1 year
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
---|---|---|
# of patients who receive contrast enhancement and CNR of CTPA scans
Tijdsspanne: 1 year
|
A secondary endpoint is to quantitatively evaluate (by comparison analysis) the contrast enhancement and CNR of CTPA scans. Twenty patients (20) will be enrolled and scanned with the RESEARCH procedures. Another twenty retrospective patients (20) with matching age and BMI will be selected from existing patients with a CLINICAL STANDARD of Care CTPA scan and enrolled on retrospective protocol: HP-00056512 "Individually optimized uniform contrast enhancement in CT angiography for the diagnosis of pulmonarythromboembolic disease - A simulation study". |
1 year
|
Medewerkers en onderzoekers
Onderzoekers
- Hoofdonderzoeker: Wei Lu, PhD, Univerysity of Maryland Baltimore
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- HP-00063432
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .