Investigation of Plaque Instability Using Bevacizumab-800CW and MSOT (Carotid)
Investigation of Plaque Instability: Identification of Atherosclerotic Plaque Angiogenesis Using Bevacizumab-800CW and Optoacoustic Imaging: a Single Center Proof of Concept Study (CAROTID-OPTOLIGHT)
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Szczegółowy opis
Rationale: This project consists of the realization followed by the clinical validation of a procedure dedicated to detect vulnerable atherosclerotic plaques patients with a symptomatic carotid stenosis. If in the future it would be possible to detect a symptomatic carotid atherosclerotic plaque non- invasively (i.e. those plaques resulting in cerebrovascular accidents and/or transient ischemic attacks), this would strongly improve risk assessment among this large cohort of patients. At the moment, indications for intervention are primarily based on degree of stenosis, and not on degree of vulnerability. Symptomatology is considered, but clinicians are not capable of predicting the consequences of a first event, while two thirds of all patients with a major stroke are not preceded by previous minor symptoms. Previous trials (NASCET and ECST) showed a significant absolute risk reduction for symptomatic patients with a stenotic lesion of the internal carotid artery greater than 70% after the performance of a carotid endarterectomy (CEA; excision of the atherosclerotic plaque). However, surgery can be associated with significant morbidity and even mortality. On the other hand, reliable prediction prior to surgery whether an atherosclerotic plaque is going to become symptomatic could also prevent unnecessary surgery, which again significantly reduces morbidity and mortality.
In literature and our preliminary ex vivo data with a nuclear imaging tracer 89Zr-Bevacizumab, it appears that vulnerable atherosclerotic plaques (i.e. those likely to become symptomatic) have an increased rate of angiogenesis at the site of the rupture (i.e. the site of the vulnerable plaque) which expose highly upregulated Vascular Endothelial Growth Factor-A (VEGF-A) production as part of the inflammatory response within the plaque and subsequently which can be visualized with a tracer targeting specifically VEGF-A. Recently, these experiments have been repeated using Bevacizumab- CW800 showing similar results (Huisman et al, preliminary data).
An intraoperative near-infrared fluorescence (NIRF) imaging camera, among a NIR fluorescence endoscopy system, and the use of the optical contrast agent Bevacizumab-800CW in now more than 250 patients has been evaluated for its feasibility to detect tumor lesions in patients with colorectal cancer, colon polyps, Barret's esophagus, peritoneal carcinomatosis of colorectal cancer origin and breast cancer. These studies showed that bevacizumab-800CW is safe in clinical use and feasible to detect even small tumor lesions with a high sensitivity. While Bevacizumab-800CW can also detect the soluble ligand VEGF-A, as shown by ex vivo analyses of excised CEA specimen, we aim to investigate whether systemic administered Bevacizumab-800CW can be applied to patients preoperatively for the detection of vulnerable plaques by non-invasive optoacoustic imaging and subsequently ex vivo mesoscopic imaging for validation purposes. The primary objective for the proposed study is to achieve pre-operative detection of the atherosclerotic plaque for patients with a symptomatic carotid artery stenosis by non-invasive optoacoustic imaging. In this study we will introduce the following concept: a preoperative non-invasive optoacoustic-scan guided by the © UMCG october 2018 Version 2.0 7 of 40
Bevacizumab-800CW targeted VEGF-A. This will help us to detect if and at what time point within the atherosclerotic plaque there is an upregulation of angiogenesis which can cross-correlated by ex vivo analyses of characteristics of the vulnerable plaque (i.e. atheroma, foam cells, influx of activated macrophages and angiogenesis as a result of pro-inflammatory responses present in the plaque). The end-goal of the proposed dual pre- and intra-operative imaging procedure is to prove that the symptomatic carotid atherosclerotic plaque can be accurately and safely detected by VEGF-A targeted optical imaging agents. In addition, this study serves as a step-up to a larger non-invasive VEGF-A targeted optical imaging study expanding the detection technology by using a new non- invasive multispectral optoacoustic detection system. Ultimately, VEGF-A targeted imaging in carotid stenosis could be used to predict vulnerability of the atherosclerotic plaque non-invasively in order to select those patients who will benefit the most of a surgical procedure.
Objective:
This feasibility study has two objectives:
- To investigate whether it's feasible to detect plaques within the carotid artery using optoacoustic imaging with the innovative MSOT Acuity Echo in patients with symptomatic carotid stenosis.
- To investigate whether the VEGF-targeted optical imaging agent Bevacizumab-800CW is able to detect VEGF upregulation as a characteristic of the vulnerable plaque in carotid tissue by means of pre-operative Bevacizumab-800CW optoacoustic imaging in patients with symptomatic carotid stenosis cross-correlated by ex vivo histopathological analyses.
Study design: Interventional phase 1 technical feasibility study: non-randomized, open label, uncontrolled with single group proof of concept study. This study will be carried out at the University Medical Center Groningen, Department of Surgery and Department of Nuclear Medicine and Molecular Imaging. Further analysis of sections of the plaques will be done at the Department of Pathology at the UMCG and by the Helmholtz Institute, Biomedical Research Centre, München.
Study population: Patients planned for elective endarterectomy for symptomatic carotid stenosis will undergo prior to surgery imaging with an optoacoustic device before and after intravenous injection with the VEGF-targeted optical imaging agent Bevacizumab-800CW.
Intervention: Patients planned to undergo endarterectomy for symptomatic carotid stenosis will be consented for this study. The procedure will in no way delay the time interval between onset of symptoms and intervention. Three days before the planned fluorescent optoacoustic scanning, the patients will undergo optoacoustic imaging as a reference. Patients then receive an intravenous injection of 4,5 mg flat-dose of Bevacizumab-800CW. Three days after tracer administration, mostly
© UMCG october 2018 Version 2.0 8 of 40
the day patients are admitted to the hospital as standard-of-care, patients will undergo final optoacoustic imaging.
Main study parameters/endpoints:
Primary Objective:
- Feasibility of optoacoustic imaging to image the carotid artery and detect plaque formation in patients with symptomatic carotid artery disease.
- Pre-operative detection of the atherosclerotic plaque in symptomatic carotid stenosis by the VEGF-targeted optical imaging agent optical imaging agent Bevacizumab-800CW using optoacoustic imaging subsequently correlated ex vivo for VEGF upregulation within the plaque indicative for increased angiogenesis.
Typ studiów
Typ studiów
Zapisy (Oczekiwany)
Zapisy
Faza
Faza
- Nie dotyczy
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
Patients above the age of 21 with an indication to undergo a carotid endarterectomy for suspected symptomatic atherosclerotic plaque based on the presence of a CVA and/or transient ischemic attacks (TIA's), including amourosis fugax.
- Patients with significant and symptomatic carotid stenosis who are scheduled for carotid endarterectomy as decided by the surgeon or the Multi-Disciplinary Carotid Board
Exclusion Criteria:
- Medical or psychiatric condition that compromises the patient's ability to give informed consent
- Pregnant or lactating women
- Significantrenal(creatinine>110μmol/L)dysfunction
- History of iodine allergy or anaphylactic reactions to insect bites or medication or previous allergic reaction to bevacizumab
- Presence or history of hyperthyroidism
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Wykonalność urządzenia
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Eksperymentalny: Optoacoustic imaging
Optoacoustic Imaging before and after tracer administration
|
Multispectral Optoacoustic Tomography is a new emerging imaging technique which uses laser light to heat up molecules with a high pulsed laser.
The molecules undergo thermal expansion and produces sound waves, which can be detected by special transducers.
The device can pick up different signals in different wavelength to produce images with anatomic and biological information.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Feasibility of MSOT imaging
Ramy czasowe: 12 months
|
Feasibility of optoacoustic imaging to image the carotid artery and detect plaque formation in patients with symptomatic carotid artery disease.
|
12 months
|
|
Ex vivo imaging
Ramy czasowe: 12 months
|
Pre-operative detection of the atherosclerotic plaque in symptomatic carotid stenosis by the VEGF-targeted optical imaging agent optical imaging agent Bevacizumab-800CW using optoacoustic imaging subsequently correlated ex vivo for VEGF upregulation within the plaque indicative for increased angiogenesis.
|
12 months
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Location of Fluorescence
Ramy czasowe: 12 months
|
Presence of fluorescent signaling after excision of the atherosclerotic plaque ex vivo as determined by flatbed scanning and fluorescence microscopy.
|
12 months
|
Współpracownicy i badacze
Sponsor
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Oczekiwany)
Rozpoczęcie studiów
Zakończenie podstawowe (Oczekiwany)
Zakończenie podstawowe
Ukończenie studiów (Oczekiwany)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- 201800515
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na MultiSpectral Optoacoustic Tomography
-
NCT06966297ZakończonyChoroby naczyniowe | PODKŁADKA
-
NCT06994260Jeszcze nie rekrutacjaMalformacje żylne | Malformacja limfatyczna | Malformacja naczyniowa | Malformacja tętniczo-żylna
-
NCT01757678Zakończony
-
NCT07150546RekrutacyjnyNieoperacyjny nowotwór neuroendokrynny układu pokarmowego | Nieoperacyjny guz neuroendokrynny układu pokarmowego G1 | Guz neuroendokrynny układu pokarmowego | Nieskorny układ trawienny guz neuroendokrynny G2