Blood Flow Quantification Near Stented SFA Lesions Using Ultrasound Velocimetry (EchoPIV in SFA)
Feasibility of Ultrasound Particle Image Velocimetry to Quantify Flow Near Stented SFA Lesions
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Gelderland
-
Arnhem, Gelderland, Holandia
- Rijnstate Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Scheduled endovascular treatment of a lesion in the SFA through placement of a bare metal or a covered stent
- A recently (<6 weeks) treated lesion in the SFA through placement of a bare metal or a covered stent
Exclusion Criteria:
- Hypersensitivity to the active substance(s) or any of the excipients in SonoVue
- Right-to-left cardiac shunt
- Severe pulmonary hypertension (pulmonary artery pressure > 90mmHg)
- Uncontrolled systemic hypertension
- Adult respiratory distress syndrome
- Severe pulmonary disease (e.g. COPD GOLD 3/4, adult respiratory distress syndrome)
- Clinically unstable cardiac disease (recent or ongoing myocardial infarction, unstable angina at rest, recent percutaneous coronary intervention, clinically worsening cardiac symptoms, severe cardiac arrythmia's, endocarditis, etc.)
- Prosthetic valves
- Loss of renal function (GFR < 31 ml/min), end-stage renal disease
- End-stage liver disease Sepsis
- Hypercoagulable status, recent thrombosis
- Congestive heart failure (class III or IV)
- Hypersensitivity to iodinated contrast media
- Pregnancy
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Liczba grup / kohort
Kohorty i interwencje
Grupa / KohortaGrupa / Kohorta |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
PAD patients
The entire cohort exists of patients recently treated with an endovascular stent placement in the superficial femoral artery (SFA).
|
Patients will undergo high-frame-rate contrast-enhanced ultrasound measurements, within 6 to 8 weeks after the endovascular procedure, at the vascular center of Rijnstate hospital.
Prior to these measurements a venous cannula will be placed to ensure venous access for the contrast administration.
Patients will undergo a CTA scan of the lower extremities at the Radiology dept. of Rijnstate hospital the same day as the echoPIV measurements.
This CTA scan serves as a reference for the vessel geometry and stent location.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Qualitative assessment vector velocity fields
Ramy czasowe: 6 to 8 weeks after the procedure (stent placement of SFA)
|
Vector velocity fields derived from the echoPIV data will be used to calculate and visualize the velocity profile.
In order to answer the question regarding feasibility of echoPIV the quality of the vector velocity fields will be assessed using three different metrics of which the first one is a qualitative assessment by different observers.
Recordings of the contrast-enhanced ultrasound with an overlay of the vector velocity profiles will be reviewed on different topics following a scoring rubrics.
|
6 to 8 weeks after the procedure (stent placement of SFA)
|
|
Contrast-to-background ratio
Ramy czasowe: 6 to 8 weeks after the procedure (stent placement of SFA)
|
The contrast-to-background ratio (CBR) is the second metric to assess the outcomes of the echoPIV measurements.
The CBR is a quantitative measure for the contrast levels and therefore for the quality of the contrast-enhanced US image.
The higher the CBR level (in dB) the higher the intensity of the contrast which is needed for sufficient PIV analysis.
|
6 to 8 weeks after the procedure (stent placement of SFA)
|
|
Vector correlation
Ramy czasowe: 6 to 8 weeks after the procedure (stent placement of SFA)
|
The vector correlation is the third metric to assess the outcomes of the echoPIV measurements.
The vector correlation demonstrates the tracking performance of the PIV algorithm.
The vector correlation provides a unitless value between 0 and 1 in which 0 indicates poor tracking of the microbubble contrast and 1 indicates perfect tracking of the microbubble contrast.
|
6 to 8 weeks after the procedure (stent placement of SFA)
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Vorticity
Ramy czasowe: 6 to 8 weeks after the procedure (stent placement of SFA)
|
Multiple blood flow parameters will be derived from the echoPIV data.
The first one is the vorticity, or the curl of the velocity.
The vorticity represents the rotation of particles inside the flow field.
This measure can potentially be used to define regions with disturbed blood flow, as a high value (in rad/s) indicates the occurence of a recirculation.
|
6 to 8 weeks after the procedure (stent placement of SFA)
|
|
Vector complexity
Ramy czasowe: 6 to 8 weeks after the procedure (stent placement of SFA)
|
The second blood flow parameters derived from the echoPIV data is the vector complexity.
Vector complexity is a measure of multi-directional flow, ranging from 0 till 1. a value of 1 means complex flow with all velocity vectors pointing in all directions, whereas a value of 0 means laminar flow with all velocity vectors pointing in the same direction.
This measure can potentially be used to indicate regions with disturbed blood flow.
|
6 to 8 weeks after the procedure (stent placement of SFA)
|
|
Correlation echoPIV and CFD
Ramy czasowe: 6 to 8 weeks after the procedure (stent placement of SFA)
|
Velocity profiles obtained with echoPIV will be compared to outcomes of a computational fluid dynamics (CFD) simulation model of the femoral artery.
Multiple points along the imaged vessel will be selected in both the echoPIV and the CFD data to extract the temporal velocity profile.
This profile will be compared point-by-point after which the correlation between both outcomes/techniques will be obtained.
|
6 to 8 weeks after the procedure (stent placement of SFA)
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Główny śledczy: Michel MPJ Reijnen, PhD, Dept. of Surgery, Rijnstate Hospital Arnhem
Publikacje i pomocne linki
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- 2018-1206
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .