Detection of Cardiac Amyloidosis Using Right Ventricular Sensing Amplitude in Patients With Left Ventricular Hypertrophy (DETECT-AMY)
Diagnostic Performance of Right Ventricular Sensing Amplitude and Other Electrophysiological,Echographic, and Histological Parameters in Cardiac Amyloidosis Among Patients With Left Ventricular Hypertrophy: a Multicenter Prospective Study
This multicenter prospective study aims to evaluate the diagnostic performance of right ventricular sensing amplitude measured during cardiac implantable electronic device (CIED) implantation (pacemaker or defibrillator) to identify cardiac amyloidosis in patients with left ventricular hypertrophy and conduction abnormalities.
Patients aged 65 years or older referred for CIED implantation will be included. During the procedure, electrophysiological parameters will be recorded.
Additional assessments will be performed, including cardiac scintigraphy, biological analyses, and subcutaneous adipose tissue biopsy. The results of these investigations will be used to confirm or rule out cardiac amyloidosis.
Diagnostic performance will be assessed using the area under the receiver operating characteristic curve (AUROC).
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Typ studiów
Typ studiów
Zapisy (Szacowany)
Zapisy
Faza
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kontakt w sprawie studiów
Kontakt w sprawie studiów
- Nazwa: Samia BALOUL
- Numer telefonu: 0149 81 33 85
- E-mail: samia.baloul@aphp.fr
Kopia zapasowa kontaktu do badania
- Nazwa: Philippe Le Corvoisier, MD, PhD
- Numer telefonu: 01 49 81 37 96
- E-mail: philippe.lecorvoisier@aphp.fr
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- Patient referred for CIED implantation (pacemaker or Implantable Cardioverter Defibrillator with a pacemaker feature) due to at least one conduction abnormality (Atrioventricular block, Sinoatrial block or Atrial fibrillation with slow ventricular rate). Patients referred for implantation of an Implantable Cardioverter Defibrillator with a pacemaker feature can be included if they present one of these conduction abnormalities.
- Left ventricular hypertrophy definite as maximal end-diastolic interventricular septum thickness ≥ 12mm
- Patients aged ≥ 65 years
- Written consent
- Patient affiliated to a social security
Exclusion Criteria:
- Severe aortic stenosis (valve area ≤ 1 cm2)
- Known cardiac amyloidosis
- Indication for cardiac resynchronisation therapy
- Indication for left bundle branch physiological pacing
- Ejection fraction < 45% on echocardiography.
- Participation in another interventional study involving human participants or being in the exclusion period at the end of a previous study involving human participants.
- Patient on AME (state medical aid)
- Adults subject to a legal protection measure (guardianship, curatorship, or safeguard of justice).
- Patients deprived of their liberty by a judicial or administrative decision.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Diagnostyczny
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Inny: Diagnostic Assessment During CIED Implantation
Single Group
|
Procedure of CIED implantation will not be modified by inclusion in the study. However, several exams will be performed to confirm or ruled out the diagnosis of cardiac amyloidosis: During the procedure: Subcutaneous adipose tissue sampling Collection of a subcutaneous adipose tissue sample during device implantation for histological analysis to detect amyloid deposits. Blood sampling for serum free light chain assay, serum and urine electrophoresis with immunofixation (baseline visit) Diagnostic Test: 99mTc-DPD or HMDP Scintigraphy Cardiac scintigraphy performed within 3 months after implantation to assess myocardial tracer uptake and detect cardiac amyloidosis. |
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Area under the receiver operating characteristic curve (AUROC) of the right ventricular sensing amplitude for the identification of patients with cardiac amyloidosis
Ramy czasowe: During CIED implantation
|
The area under the receiver operating characteristic curve (AUROC) of the right ventricular sensing amplitude, measured during CIED implantation in patients with conduction abnormalities, for the identification of patients with cardiac amyloidosis.
|
During CIED implantation
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Diagnostic performance of right atrial sensing amplitude for diagnostic of cardiac amyloidosis
Ramy czasowe: During hospitalization for CEID implantation (Day 0)
|
The area under the receiver operating characteristic curve (AUROC) and sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios of right atrial sensing amplitude, atrial and ventricular pacing thresholds estimated during CIED implantation for identifying patients with cardiac amyloidosis.
|
During hospitalization for CEID implantation (Day 0)
|
|
Diagnostic performance of atrial pacing thresholds for diagnostic of cardiac amyloidosis
Ramy czasowe: During hospitalization for CEID implantation (Day 0)
|
The area under the receiver operating characteristic curve (AUROC) and sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios of right atrial sensing amplitude, atrial and ventricular pacing thresholds estimated during CIED implantation for identifying patients with cardiac amyloidosis.
|
During hospitalization for CEID implantation (Day 0)
|
|
Diagnostic performance of ventricular pacing thresholds for diagnostic of cardiac amyloidosis
Ramy czasowe: During hospitalization for CEID implantation (Day 0)
|
The area under the receiver operating characteristic curve (AUROC) and sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios of right atrial sensing amplitude, atrial and ventricular pacing thresholds estimated during CIED implantation for identifying patients with cardiac amyloidosis.
|
During hospitalization for CEID implantation (Day 0)
|
|
Diagnostic performance of maximal end-diastolic interventricular septal thickness
Ramy czasowe: During hospitalization for CEID implantation (Day 0)
|
The area under the receiver operating characteristic curve (AUROC) and sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios of maximal end-diastolic interventricular septum thickness at echocardiography for identifying patients with cardiac amyloidosis.
|
During hospitalization for CEID implantation (Day 0)
|
|
Diagnostic performance of adipose tissue histology
Ramy czasowe: During hospitalization for CEID implantation (Day-0)
|
The area under the receiver operating characteristic curve (AUROC) and sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios of histological analysis of adipose tissue for identifying patients with cardiac amyloidosis.
|
During hospitalization for CEID implantation (Day-0)
|
|
Diagnostic performance of right atrial and ventricular sensing amplitudes and pacing thresholds
Ramy czasowe: 6 months after CIED implantation (Day 0)
|
The area under the receiver operating characteristic curve (AUROC) and sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios of 12-lead electrocardiogram data (low voltage in limb leads) for identifying patients with cardiac amyloidosis.
|
6 months after CIED implantation (Day 0)
|
|
The implantation procedure duration (min) between patients with or without cardiac amyloidosis
Ramy czasowe: During CIED implantation
|
During CIED implantation
|
|
|
The prevalence of cardiac amyloidosis in the study population
Ramy czasowe: Up to 3 months after CIED implantation
|
Up to 3 months after CIED implantation
|
|
|
The proportion of modifications in the treatment at the 6-month visit.
Ramy czasowe: 6 months after CIED implantation
|
6 months after CIED implantation
|
|
|
Change in RAND 36-Item Health Survey (SF-36) score
Ramy czasowe: Inclusion and 6 months after CIED implantation
|
Change in health-related quality of life between inclusion and the 6-month visit, assessed using the RAND 36-Item Health Survey, Version 1.0 (SF-36).
The questionnaire comprises 36 items grouped into 8 domains.
Each domain score ranges from 0 to 100, with higher scores indicating better health-related quality of life.
|
Inclusion and 6 months after CIED implantation
|
|
Change in New York Heart Association (NYHA) Functional Classification
Ramy czasowe: Inclusion and 6 months after CIED implantation
|
Change in New York Heart Association (NYHA) Functional Classification between baseline and the 6-month visit in patients with and without cardiac amyloidosis.
The NYHA Functional Classification ranges from Class I to Class IV, with higher class indicating worse functional status.
|
Inclusion and 6 months after CIED implantation
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Krzesło do nauki: Philippe Le Corvoisier, MD, PhD, Assistance public Hôpitaux de Paris
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Rozpoczęcie studiów
Zakończenie podstawowe (Szacowany)
Zakończenie podstawowe
Ukończenie studiów (Szacowany)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
- Choroby Układu Nerwowego
- Choroby układu krążenia
- Stany patologiczne, anatomiczne
- Choroby serca
- Choroby nerwowo-mięśniowe
- Metabolizm, Wrodzone Błędy
- Choroby genetyczne, wrodzone
- Choroby metaboliczne
- Choroby obwodowego układu nerwowego
- Choroby neurodegeneracyjne
- Choroby zwyrodnieniowe układu nerwowego
- Niedobory proteostazy
- Kardiomegalia
- Neuropatie amyloidowe
- Amyloidoza, rodzinna
- Hipertrofia
- Amyloidoza
- Wrodzone, dziedziczne i noworodkowe choroby i nieprawidłowości
- Stany patologiczne, oznaki i objawy
- Choroby żywieniowe i metaboliczne
- Przerost lewej komory
- Neuropatie amyloidowe, rodzinne
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- APHP240915
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .