Subclinical Optic Nerve Changes After Le Fort I Osteotomy
Evaluation of Subclinical Optic Nerve Head Changes After Le Fort I Osteotomy Using Retinal Nerve Fiber Layer Optical Coherence Tomography
Le Fort I osteotomy is a common jaw surgery that includes a step called pterygomaxillary dysjunction, during which force applied with a surgical instrument (osteotome) can be transmitted toward the eye socket (orbit) and the optic nerve canal. Serious eye complications after this surgery are rare, but it is not known whether smaller, subclinical changes occur in the optic nerve that go unnoticed without special testing. This study uses a non-invasive eye imaging test called optical coherence tomography (OCT) to measure the thickness of the nerve fiber layer around the optic nerve, before and after Le Fort I surgery, to find out whether such changes occur.
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Szczegółowy opis
Fifty patients aged 18-45 years scheduled for isolated Le Fort I osteotomy or Le Fort I osteotomy combined with bilateral sagittal split osteotomy (BSSO) will be enrolled in this single-center, prospective, observational cohort study. Each patient serves as their own control (within-subject comparison across time points). All participants will undergo ophthalmologic examination, RNFL-OCT imaging, optic disc morphology assessment (disc area, elongation ratio, presence of disc head hemorrhage), and Humphrey 30-2 visual field testing at three time points: preoperatively (T0, within 1 week before surgery), 1 week postoperatively (T1), and 3 months postoperatively (T2). All ophthalmologic measurements will be performed by a single examiner blinded to intraoperative surgical details, using the same device throughout. Maxillary advancement amount and pterygomaxillary junction depth/concavity angle will be measured preoperatively on CBCT (pterygomaxillary junction measured bilaterally, with Observer 1 measuring twice for intraobserver reliability and Observer 2 measuring once for interobserver reliability). No intervention, randomization, or treatment-group allocation occurs as part of this study; all participants receive their routine, already-planned orthognathic surgical care. A priori power analysis (G*Power, RM ANOVA within-between interaction, f=0.25, epsilon=1, alpha=0.05, power=0.90) indicated a minimum required sample size of N=36; n=50 was set to allow for attrition.
Typ studiów
Typ studiów
Zapisy (Szacowany)
Zapisy
Kontakty i lokalizacje
Kontakt w sprawie studiów
Kontakt w sprawie studiów
- Nazwa: Yağmur M Okumuş, Assistant Professor, DDS, Phd
- Numer telefonu: +90 5304054615
- E-mail: yagmur.malkoc@medipol.edu.tr
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Adult patients aged 18-45 years scheduled for isolated Le Fort I osteotomy or Le Fort I combined with bilateral sagittal split osteotomy (BSSO) at Istanbul Medipol University, with no pre-existing ocular or orbital pathology that could independently affect retinal nerve fiber layer thickness or optic disc morphology.'
Opis
Inclusion Criteria:
Aged 18-45 years, able to provide written informed consent. Isolated Le Fort I osteotomy or Le Fort I + BSSO (bilateral sagittal split osteotomy) planned.
ASA Physical Status Classification I-II. Standard osteotome technique used for pterygomaxillary dysjunction. Sufficient ocular media clarity to permit OCT imaging.
Exclusion Criteria:
Known glaucoma, optic neuropathy, retinal disease, or other ocular pathology affecting the retinal nerve fiber layer.
Prior ocular/orbital surgery or trauma. Craniofacial syndrome (e.g., cleft lip/palate). Segmental Le Fort osteotomy or revision orthognathic surgery. Unwilling or unable to provide informed consent.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Modele obserwacyjne: COHORT
- Perspektywy czasowe: OTHER
Liczba grup / kohort
Kohorty i interwencje
Grupa / KohortaGrupa / Kohorta |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Le Fort I osteotomy cohort
Patients undergoing isolated Le Fort I osteotomy or Le Fort I combined with bilateral sagittal split osteotomy (BSSO). No randomization or treatment allocation; all participants receive their routine, already-planned orthognathic surgical care. Diagnostic Test: RNFL-OCT and optic disc morphology assessment (disc area, elongation ratio, disc head hemorrhage), performed preoperatively (T0) and at 1 week (T1) and 3 months (T2) postoperatively. Diagnostic Test: Humphrey 30-2 visual field testing, performed at the same three time points. Diagnostic Test: Preoperative CBCT measurement of pterygomaxillary junction depth and concavity angle, and maxillary advancement amount from surgical planning data. |
Peripapillary retinal nerve fiber layer thickness and optic disc morphology (disc area, elongation ratio, presence of disc head hemorrhage) measured by optical coherence tomography, performed preoperatively (T0) and at 1 week (T1) and 3 months (T2) postoperatively. Humphrey 30-2 Visual Field Testing Açıklama: Standard automated perimetry (Humphrey 30-2 program) performed at the same three time points (T0, T1, T2) to assess mean deviation and pattern standard deviation. Cone-beam computed tomography measurement of pterygomaxillary junction depth and concavity angle, and maxillary advancement amount from virtual surgical planning data, obtained preoperatively. |
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Change in Peripapillary Retinal Nerve Fiber Layer (RNFL) Thickness
Ramy czasowe: Baseline (T0, preoperative) to 3 months (T2) postoperatively
|
Change in peripapillary retinal nerve fiber layer (RNFL) thickness, measured by optical coherence tomography (OCT), from baseline (T0, preoperative) to 1 week (T1) and 3 months (T2) after Le Fort I osteotomy. |
Baseline (T0, preoperative) to 3 months (T2) postoperatively
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Change in Optic Disc Area and Elongation Ratio
Ramy czasowe: Baseline (T0) to 3 months (T2) postoperatively
|
Change in optic disc area and elongation ratio (vertical/horizontal), measured by OCT, from baseline (T0) to 1 week (T1) and 3 months (T2) after Le Fort I osteotomy. |
Baseline (T0) to 3 months (T2) postoperatively
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Dyrektor Studium: Sina Uçkan, prof., Medipol University
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Rozpoczęcie studiów
Zakończenie podstawowe (Szacowany)
Zakończenie podstawowe
Ukończenie studiów (Szacowany)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- IstanbulMUH-DF-YM-03
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .