- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT03247465
Image Fusion and Calcification Raising in Trans Aortic Valve Implantation (TAVI)
Value of Fusion of 3D Images With 2D Images, Associated With Calcification Raising During Trans Aortic Valve Implantation Procedures
Aortic stenosis is one of the most common cardiology diseases. Trans aortic valve implantation (TAVI) has been developed since 2002, first to treat rejected patients from conventional surgery, then to treat high surgical risk patients and nowadays probably intermediate surgical risk patient. TAVI related complications are still recurrent and the investigators are searching a way to decrease them.
One of them could be image fusion, since it may decrease radiation exposure and contrast agent use. It may also improve valve placement position leading to decreased complications.
40 prospective and consecutive patients will be included. Participants will be divided into two groups: the 20 first included will be control group, the 20 following patients will be the fusion group. For control group TAVI procedure will be the usual one, for fusion group the procedure will be the usual one with addition of computed tomography 3D images fusion with fluoroscopy 2D images.
Main evaluation criteria will be radiation exposure, measured by dose area product (DAP). Secondary evaluation criterion will be procedural as contrast agent volume used, procedure duration, subjective usefulness of image fusion or procedure failure evaluated immediately after procedure. The investigators will also evaluated procedure induced complications as de novo pacemaker implantation, de novo left bundle branch, vascular complication, major bleeding, acute kidney failure, significant aortic regurgitation. These complications occurrence will be evaluated after 1 month follow up, during the usual following consultation.
Przegląd badań
Status
Interwencja / Leczenie
Szczegółowy opis
Aortic stenosis is one of the most common cardiology diseases. If untreated, symptomatic aortic stenosis rapidly leads to death. Most of the time, this disease affects old fragile people for whom conventional surgery is countered or very risky. That is why Trans aortic valve implantation has been developed since 2002, first to treat rejected patients from conventional surgery, then to treat high surgical risk patients and nowadays probably intermediate surgical risk patient. Indeed, thanks to prodigious technical and human progress, procedure induced complication have clearly decreased. But TAVI related complications are still recurrent and the investigators are searching a way to decrease them.
One of them could be image fusion, since it may decrease radiation exposure and contrast agent use correlated to acute kidney failure. It may also improve valve placement position, and the investigators know that many rhythmic (atrio-ventricular block) and valvular (significant aortic regurgitation) complications are partially due to placement mistakes. So the investigators hope that image fusion will decrease these complications.
The investigators will include 40 prospective and consecutive patients. Inclusion criterion will be all major patients admitted in Nantes CHU for transfemoral aortic valve replacement with SAPIEN® 3 valve. Exclusion criterion will be women of childbearing age without contraception, impossible written consent, judiciary protected people. After inclusion, patients will be divided into two groups: the 20 first included will be control group, the 20 following patients will be the fusion group. For control group TAVI procedure will be the usual one, for fusion group the procedure will be the usual one with addition of computed tomography 3D images fusion with fluoroscopy 2D images. The only difference during all patient medical care will be the addition of image fusion in fusion group. Before and after procedure, both groups will have the usual medical monitoring and the appropriated medical interventions to participants case.
Main evaluation criterion will be radiation exposure, measured by dose area product (DAP).
Secondary evaluation criterion will be procedural as:
- contrast agent volume used (mL),
- procedure duration (min),
- subjective usefulness of image fusion evaluated on a 0 to 3 scale
- procedure failure : death, more than one valve implantation, valve dysfunction (mean trans-valvular gradient > 20 mmHg or moderate to severe aortic regurgitation) These criterions will be evaluated immediately after procedure.
The investigators will also evaluated procedure induced complications as:
- de novo pacemaker implantation
- de novo left bundle branch
- non minor vascular complication on VARC-2 definition
- major bleeding (BARC 3 or 5)
- acute kidney failure (AKIN 2 or 3)
- significant aortic regurgitation ≥ 2/4 These complications occurrence will be evaluated after 1 month follow up, during the usual following consultation with echocardiography.
Then differences between will be tested with appropriated statistical methods.
Typ studiów
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Nantes, Francja, 44093
- Nantes University Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- All patients admitted in Nantes CHU for trans fermoral aortic valve replacement with SAPIEN 3® device
- Patient who accepted to participate to the study
Exclusion Criteria:
- Impossible written consent
- Judiciary protected people
- Minor
- Women of childbearing age without contraception
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Inny
- Przydział: Nielosowe
- Model interwencyjny: Przydział równoległy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: Group "Fusion"
Trans aortic valve replacement with usual procedure with the addition of computed tomography 3D images and calcification raising to the usual fluoroscopy images.
|
Addition of computed tomography 3D images and calcification raising to the usual fluoroscopy images.
|
|
Brak interwencji: Group "Control"
Trans aortic valve replacement with usual procedure
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Radiation exposure
Ramy czasowe: Immediately post procedure
|
Dose area product (cGy/cm2)
|
Immediately post procedure
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Contrast product
Ramy czasowe: Immediately post procedure
|
Contrast volume (mL) used during procedure
|
Immediately post procedure
|
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- RC17_0114
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Image Fusion
-
Imperial College LondonCancer Research UK; National Institute for Health Research, United KingdomRekrutacyjnyNowotwory | Rak gruczołowy | Nowotwory prostaty | Choroby prostaty | Rak prostatyZjednoczone Królestwo
-
Urological Research Network, LLCRekrutacyjnyRak prostaty | Nowotwory ProstatyStany Zjednoczone
-
DONG WURekrutacyjnyBadania przesiewowe w kierunku raka jelita grubego | Polipy okrężnicy/kolonoskopia/nowotwory jelita grubego | Trudna kolonoskopia | Dyskomfort związany z kolonoskopiąChiny
-
Beni-Suef UniversityZakończony
-
Stanford UniversityNational Institute of Mental Health (NIMH); Washington University School of...ZakończonyZaburzenia odżywianiaStany Zjednoczone
-
Mansoura UniversityZakończonyPróchnica zębów klasa IIEgipt
-
Maquet CardiovascularZakończonyChoroba zarostowa tętnic obwodowych (PAOD)Niemcy, Austria
-
Oticon MedicalSahlgrenska University HospitalZakończonyPrzewodzeniowy ubytek słuchu | Mieszana utrata słuchuSzwecja
-
Andrews Research & Education FoundationBREG, IncZakończonyChoroba zwyrodnieniowa stawu kolanowegoStany Zjednoczone
-
Mesoblast, Ltd.ZakończonyZwyrodnieniowa choroba dysku | Zwężenie kręgosłupa | Kręgozmyk zwyrodnieniowyStany Zjednoczone