- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT03247465
Image Fusion and Calcification Raising in Trans Aortic Valve Implantation (TAVI)
Value of Fusion of 3D Images With 2D Images, Associated With Calcification Raising During Trans Aortic Valve Implantation Procedures
Aortic stenosis is one of the most common cardiology diseases. Trans aortic valve implantation (TAVI) has been developed since 2002, first to treat rejected patients from conventional surgery, then to treat high surgical risk patients and nowadays probably intermediate surgical risk patient. TAVI related complications are still recurrent and the investigators are searching a way to decrease them.
One of them could be image fusion, since it may decrease radiation exposure and contrast agent use. It may also improve valve placement position leading to decreased complications.
40 prospective and consecutive patients will be included. Participants will be divided into two groups: the 20 first included will be control group, the 20 following patients will be the fusion group. For control group TAVI procedure will be the usual one, for fusion group the procedure will be the usual one with addition of computed tomography 3D images fusion with fluoroscopy 2D images.
Main evaluation criteria will be radiation exposure, measured by dose area product (DAP). Secondary evaluation criterion will be procedural as contrast agent volume used, procedure duration, subjective usefulness of image fusion or procedure failure evaluated immediately after procedure. The investigators will also evaluated procedure induced complications as de novo pacemaker implantation, de novo left bundle branch, vascular complication, major bleeding, acute kidney failure, significant aortic regurgitation. These complications occurrence will be evaluated after 1 month follow up, during the usual following consultation.
Обзор исследования
Статус
Вмешательство/лечение
Подробное описание
Aortic stenosis is one of the most common cardiology diseases. If untreated, symptomatic aortic stenosis rapidly leads to death. Most of the time, this disease affects old fragile people for whom conventional surgery is countered or very risky. That is why Trans aortic valve implantation has been developed since 2002, first to treat rejected patients from conventional surgery, then to treat high surgical risk patients and nowadays probably intermediate surgical risk patient. Indeed, thanks to prodigious technical and human progress, procedure induced complication have clearly decreased. But TAVI related complications are still recurrent and the investigators are searching a way to decrease them.
One of them could be image fusion, since it may decrease radiation exposure and contrast agent use correlated to acute kidney failure. It may also improve valve placement position, and the investigators know that many rhythmic (atrio-ventricular block) and valvular (significant aortic regurgitation) complications are partially due to placement mistakes. So the investigators hope that image fusion will decrease these complications.
The investigators will include 40 prospective and consecutive patients. Inclusion criterion will be all major patients admitted in Nantes CHU for transfemoral aortic valve replacement with SAPIEN® 3 valve. Exclusion criterion will be women of childbearing age without contraception, impossible written consent, judiciary protected people. After inclusion, patients will be divided into two groups: the 20 first included will be control group, the 20 following patients will be the fusion group. For control group TAVI procedure will be the usual one, for fusion group the procedure will be the usual one with addition of computed tomography 3D images fusion with fluoroscopy 2D images. The only difference during all patient medical care will be the addition of image fusion in fusion group. Before and after procedure, both groups will have the usual medical monitoring and the appropriated medical interventions to participants case.
Main evaluation criterion will be radiation exposure, measured by dose area product (DAP).
Secondary evaluation criterion will be procedural as:
- contrast agent volume used (mL),
- procedure duration (min),
- subjective usefulness of image fusion evaluated on a 0 to 3 scale
- procedure failure : death, more than one valve implantation, valve dysfunction (mean trans-valvular gradient > 20 mmHg or moderate to severe aortic regurgitation) These criterions will be evaluated immediately after procedure.
The investigators will also evaluated procedure induced complications as:
- de novo pacemaker implantation
- de novo left bundle branch
- non minor vascular complication on VARC-2 definition
- major bleeding (BARC 3 or 5)
- acute kidney failure (AKIN 2 or 3)
- significant aortic regurgitation ≥ 2/4 These complications occurrence will be evaluated after 1 month follow up, during the usual following consultation with echocardiography.
Then differences between will be tested with appropriated statistical methods.
Тип исследования
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
-
Nantes, Франция, 44093
- Nantes University Hospital
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- All patients admitted in Nantes CHU for trans fermoral aortic valve replacement with SAPIEN 3® device
- Patient who accepted to participate to the study
Exclusion Criteria:
- Impossible written consent
- Judiciary protected people
- Minor
- Women of childbearing age without contraception
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Другой
- Распределение: Нерандомизированный
- Интервенционная модель: Параллельное назначение
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Экспериментальный: Group "Fusion"
Trans aortic valve replacement with usual procedure with the addition of computed tomography 3D images and calcification raising to the usual fluoroscopy images.
|
Addition of computed tomography 3D images and calcification raising to the usual fluoroscopy images.
|
|
Без вмешательства: Group "Control"
Trans aortic valve replacement with usual procedure
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Radiation exposure
Временное ограничение: Immediately post procedure
|
Dose area product (cGy/cm2)
|
Immediately post procedure
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Contrast product
Временное ограничение: Immediately post procedure
|
Contrast volume (mL) used during procedure
|
Immediately post procedure
|
Соавторы и исследователи
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- RC17_0114
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .
Клинические исследования Image Fusion
-
Imperial College LondonCancer Research UK; National Institute for Health Research, United KingdomРекрутингНовообразования | Аденокарцинома | Новообразования предстательной железы | Заболевания предстательной железы | Рак простатыСоединенное Королевство
-
Urological Research Network, LLCРекрутингРак простаты | Новообразования простатыСоединенные Штаты
-
Rabin Medical CenterНеизвестныйБиопсия простатыИзраиль
-
University of Witten/HerdeckeЗавершенныйБоль | Беспокойство | Страх | ВенепункцияГермания
-
Dartmouth-Hitchcock Medical CenterNational Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS); National... и другие соавторыЗавершенныйБоль в пояснице | Стеноз позвоночного канала | СпондилолистезСоединенные Штаты
-
Urological Research Network, LLCРекрутингРак простаты | Новообразования простатыСоединенные Штаты
-
State University of New York College of OptometryРекрутинг
-
Duke UniversityОтозванОперация | Дегенеративное заболевание дисков | Заболевание дисков шейного отдела позвоночника | Слияние позвоночника
-
Assistance Publique - Hôpitaux de ParisАктивный, не рекрутирующий
-
Andrews Research & Education FoundationBREG, IncЗавершенныйОстеоартроз коленного суставаСоединенные Штаты