Quality and Safety of Real-Time Brachytherapy Treatments: Clinical Implementation of a Multipoint Scintillation Detector for Treatment Monitoring ((CurieInVivo))
In Vivo Surveillance of Brachytherapy Using Plastic Scintillation Dosimetry: A Clinical Feasibility Study
This project addresses a key safety gap in High-Dose-Rate (HDR) brachytherapy, where very high, localized radiation doses mean that small geometric deviations in catheter placement or radioactive source positioning can cause clinically significant errors. Incident reports from the Radiation Oncology Incident Learning System (RO-ILS) of the American Society for Radiation Oncology (ASTRO) and guidelines from the American Association of Physicists in Medicine Task Group 59 (AAPM TG-59) identify these events-often occurring between imaging and treatment delivery-as among the most critical. Unlike external beam radiotherapy, brachytherapy lacks a prior phantom-based verification step, making in vivo dosimetry the only real-time method to confirm delivered dose and detect anomalies in dwell time or source position. International bodies such as the International Atomic Energy Agency (IAEA) recommend this approach for quality management and accident prevention.
Multipoint plastic scintillation detectors (mPSD) offer water-equivalent, real-time measurements and can enable three-dimensional (3D) radioactive source tracking, but their clinical use remains limited due to integration challenges and the absence of well-defined alert thresholds.
The project aims to implement a real-time in vivo monitoring solution using an mPSD at the Centre régional intégré de cancérologie (CRIC) of Lévis, Québec (QC) for HDR gynecological and prostate brachytherapy. Objectives include: (1) demonstrating clinical feasibility and integration within existing clinical workflows; (2) validating the accuracy and precision of dose, dwell-time, and source-position measurements under clinical conditions; and (3) developing practical alert thresholds to identify common deviations. The central hypothesis is that mPSD technology can provide reliable, reproducible real-time measurements without lengthening procedures or disrupting clinical workflow.
The methodology relies on adapting the HYPERSCINT® platform for HDR in vivo use. A custom mPSD, consisting of several scintillators along a single optical fiber, will be insertable into a 6-French (6F) catheter.
Phase 1 focuses on feasibility and integration, including HDR-specific calibration, definition of detector insertion scenarios, integration of acquisition hardware, and staff training.
Phase 2 validates performance in at least 20 patients. Planned treatment parameters and time-stamped detector signals acquired at 1-10 hertz (Hz) will be used to reconstruct delivered dose, dwell times, and source-to-detector distances. Measurement accuracy and reproducibility will be quantified using mixed-effects statistical models.
Phase 3 establishes preliminary alert thresholds based on deviations in dose, time, and position, along with visualization tools such as Bland-Altman plots, although these thresholds will not be applied clinically during the study.
Expected outcomes include demonstrated feasibility of in vivo mPSD monitoring, quantitative performance metrics with confidence intervals, identification of influential factors and operational recommendations, preliminary alert thresholds with reporting templates, and a roadmap for sustainable deployment in Lévis and other centers. Scientific outputs will also be produced for dissemination across the Santé Québec network.
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Typ studiów
Zapisy (Szacowany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kontakt w sprawie studiów
- Nazwa: Mathieu Goulet, PhD
- Numer telefonu: 1-418-835-7121 ext 14539
- E-mail: mathieu_goulet@ssss.gouv.qc.ca
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- Patients receiving prostate brachytherapy treatment, or female user receiving gynecological brachytherapy treatment for cervical cancer.
Exclusion Criteria:
- Patients with a Clostridium difficile infection or any other high-risk positive infection.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Inny
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: In-vivo dosimetry
Patients in this treatment arm will receive the same treatment and care as patients outside of the protocol, but will have their treatment monitored by a plastic scintillation detector placed inside or at close proximity of the tumor.
|
Typical brachytherapy treatments are conducted without dose or source position monitoring in real-time.
This intervention will assess the feasibility of using a scintillation detector to that end.
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Proportion of brachytherapy treatments with successful scintillation detector-based measurement
Ramy czasowe: From the patient anesthesia at the beginning of the brachytherapy procedure to the end of brachytherapy radiation delivery on the same day.
|
Feasibility will be assessed by determining whether a scintillation detector successfully acquires a measurement during brachytherapy treatment.
Radiation emitted from the brachytherapy source induces optical scintillation in the detector.
The emitted light is transmitted via optical fiber and collected by a spectrometer located outside the treatment room.
A successful measurement is defined as the acquisition of scintillation data that can be analyzed to infer clinically relevant parameters, including either the radiation dose rate as a function of time and/or the radioactive source position during treatment delivery.
The outcome will be reported as the number and proportion of treatments with successful measurements.
|
From the patient anesthesia at the beginning of the brachytherapy procedure to the end of brachytherapy radiation delivery on the same day.
|
Współpracownicy i badacze
Sponsor
Publikacje i pomocne linki
Publikacje ogólne
- Yamada Y, Rogers L, Demanes DJ, Morton G, Prestidge BR, Pouliot J, Cohen GN, Zaider M, Ghilezan M, Hsu IC; American Brachytherapy Society. American Brachytherapy Society consensus guidelines for high-dose-rate prostate brachytherapy. Brachytherapy. 2012 Jan-Feb;11(1):20-32. doi: 10.1016/j.brachy.2011.09.008.
- Fonseca GP, Johansen JG, Smith RL, Beaulieu L, Beddar S, Kertzscher G, Verhaegen F, Tanderup K. In vivo dosimetry in brachytherapy: Requirements and future directions for research, development, and clinical practice. Phys Imaging Radiat Oncol. 2020 Sep 28;16:1-11. doi: 10.1016/j.phro.2020.09.002. eCollection 2020 Oct.
- Linares Rosales HM, Duguay-Drouin P, Archambault L, Beddar S, Beaulieu L. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy. Med Phys. 2019 May;46(5):2412-2421. doi: 10.1002/mp.13498. Epub 2019 Apr 2.
- Linares Rosales HM, Johansen JG, Kertzscher G, Tanderup K, Beaulieu L, Beddar S. 3D source tracking and error detection in HDR using two independent scintillator dosimetry systems. Med Phys. 2021 May;48(5):2095-2107. doi: 10.1002/mp.14607. Epub 2021 Mar 28.
- Therriault-Proulx F, Beddar S, Beaulieu L. On the use of a single-fiber multipoint plastic scintillation detector for 192Ir high-dose-rate brachytherapy. Med Phys. 2013 Jun;40(6):062101. doi: 10.1118/1.4803510.
- Kubo HD, Glasgow GP, Pethel TD, Thomadsen BR, Williamson JF. High dose-rate brachytherapy treatment delivery: report of the AAPM Radiation Therapy Committee Task Group No. 59. Med Phys. 1998 Apr;25(4):375-403. doi: 10.1118/1.598232.
- Hoopes DJ, Dicker AP, Eads NL, Ezzell GA, Fraass BA, Kwiatkowski TM, Lash K, Patton GA, Piotrowski T, Tomlinson C, Ford EC. RO-ILS: Radiation Oncology Incident Learning System: A report from the first year of experience. Pract Radiat Oncol. 2015 Sep-Oct;5(5):312-318. doi: 10.1016/j.prro.2015.06.009. Epub 2015 Jun 25.
- Therriault-Proulx F, Archambault L, Beaulieu L, Beddar S. Development of a novel multi-point plastic scintillation detector with a single optical transmission line for radiation dose measurement. Phys Med Biol. 2012 Nov 7;57(21):7147-59. doi: 10.1088/0031-9155/57/21/7147. Epub 2012 Oct 12.
- Beaulieu L, Beddar S. Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy. Phys Med Biol. 2016 Oct 21;61(20):R305-R343. doi: 10.1088/0031-9155/61/20/R305. Epub 2016 Oct 3.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 2026-1305
- 2025 (Inny identyfikator: Faculty of Social Sciences Scientific Grant at the University of Gdańsk)
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Opis planu IPD
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Rak prostaty
-
University of ChicagoJeszcze nie rekrutacjaHER2 Pozytywne nowo zdiagnozowane przerzuty przełyku, żołądka, GEJ Cancer Pacjenci ze statusem wydajności ECOG 2
-
University of Michigan Rogel Cancer CenterNational Cancer Institute (NCI)Jeszcze nie rekrutacjaSyndrom Lyncha | Dziedziczny zespół nowotworowy | BRCA1-Related Hereditary Breast and Ovarian Cancer Syndrome | BRCA2-Related Hereditary Breast and Ovarian Cancer SyndromeStany Zjednoczone
-
Emory UniversityNational Cancer Institute (NCI)WycofanePrognostyczny rak piersi IV stopnia AJCC v8 | Przerzutowy nowotwór złośliwy w mózgu | Przerzutowy rak piersi | Anatomiczny IV stopień raka piersi American Joint Committee on Cancer (AJCC) v8
-
Jonsson Comprehensive Cancer CenterEli Lilly and Company; Genentech, Inc.Aktywny, nie rekrutującyNiedrobnokomórkowy rak płuc z przerzutami | Oporny na leczenie niedrobnokomórkowy rak płuc | Rak płuca w stadium IV American Joint Committee on Cancer (AJCC) v8 | Rak płuc w stadium IVA AJCC v8 | Rak płuc w stadium IVB AJCC v8Stany Zjednoczone
-
Jonsson Comprehensive Cancer CenterZakończonyRak prostaty oporny na kastrację | Przerzutowy rak prostaty | Stadium IVA raka prostaty AJCC v8 | Rak prostaty w stadium IVB AJCC v8 | Rak prostaty w stadium IV American Joint Committee on Cancer (AJCC) v8Stany Zjednoczone
-
Jonsson Comprehensive Cancer CenterRekrutacyjnyRak prostaty oporny na kastrację | Przerzutowy rak prostaty | Stadium IVA raka prostaty AJCC v8 | Rak prostaty w stadium IVB AJCC v8 | Rak prostaty w stadium IV American Joint Committee on Cancer (AJCC) v8Stany Zjednoczone
-
Jonsson Comprehensive Cancer CenterZakończonyBiochemicznie nawracający rak prostaty | Przerzutowy rak prostaty | Nowotwór złośliwy z przerzutami w kości | Stadium IVA raka prostaty AJCC v8 | Rak prostaty w stadium IVB AJCC v8 | Rak prostaty w stadium IV American Joint Committee on Cancer (AJCC) v8Stany Zjednoczone
-
Jonsson Comprehensive Cancer CenterNational Cancer Institute (NCI)ZakończonyGruczolakorak gruczołu krokowego III stopnia AJCC v7 | Gruczolakorak gruczołu krokowego II stopnia AJCC v7 | Stopień I gruczolakoraka gruczołu krokowego American Joint Committee on Cancer (AJCC) v7Stany Zjednoczone
-
NRG OncologyNational Cancer Institute (NCI)ZakończonyAnatomiczny rak piersi IV stadium AJCC v8 | Prognostyczny rak piersi IV stopnia AJCC v8 | Nowotwór złośliwy z przerzutami w kości | Przerzutowy nowotwór złośliwy w węzłach chłonnych | Przerzutowy nowotwór złośliwy w wątrobie | Przerzutowy rak piersi | Przerzutowy nowotwór złośliwy w płucach | Nowotwór... i inne warunkiStany Zjednoczone, Kanada, Arabia Saudyjska, Korea Południowa
-
National Cancer Institute (NCI)ZakończonyOporny na leczenie złośliwy nowotwór lity | Nawracający złośliwy nowotwór lity | Przerzutowy złośliwy nowotwór lity | Nieoperacyjny lity nowotwór | Nawracający rak drobnokomórkowy płuca | Stopień IIIA Rak drobnokomórkowy płuca AJCC v7 | Etap IIIB Rak drobnokomórkowy płuca AJCC v7 | Rak drobnokomórkowy... i inne warunkiStany Zjednoczone