Narrow Band Imaging Colon Polyp Study
A Multicenter, Prospective, Randomized Controlled Trial for the Detection of Colon Polyps and Predicting Histology
In this study the investigators hypothesize that High Definition White Light colonoscopy and narrow band imaging (NBI) will detect a higher number of adenomas compared to standard definition white light colonoscopy. NBI will have a higher accuracy in predicting polyp histology compared to high definition colonoscopy and standard colonoscopy.
Specific Aim 1 - To compare the prevalence of adenomas detected by standard colonoscopy, high-definition white light colonoscopy and NBI.
Specific Aim 2 - To compare the number of adenoma detected per subject by standard colonoscopy, high-definition white light colonoscopy and NBI.
Specific Aim 3 - To compare the accuracy of predicting polyp histology between standard colonoscopy, high-definition white light colonoscopy and NBI by evaluating the surface mucosal and vascular patterns during the procedure.
Specific Aim 4 - To determine the inter-observer agreement between investigators for the recognition of various polyp patterns
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Descrição detalhada
This study is a multi-center randomized controlled trial that will be conducted at the Kansas City VA Medical Center, Kansas City, MO and The Barnes Jewish Hospital, St Louis, MO. Patients referred for screening and surveillance colonoscopy will be enrolled. They will be randomized to one of the following three groups: standard white light colonoscopy, high-definition white light colonoscopy or NBI.
All colonoscopies will be performed at the Kansas City VA Medical Center and The Barnes Jewish Hospital, St Louis, MO. Moderate sedation will be administered for the procedure with intravenous midazolam, demerol or fentanyl and Propofol. In patients randomized to the NBI arm, the colonoscope will be inserted to the cecum under white light and will switch to NBI mode at the time of withdrawal. After cecal intubation, the colonic mucosa will be carefully visualized during withdrawal of the scope with one of the three imaging modalities to which the patient has been randomized. No effort will be made to look for polyps during the insertion of the colonoscope. All polyps detected will be documented for their size, morphology (Polypoid: sessile, pedunculated or Non polypoid: superficially elevated, completely flat, depressed), and location. The surface of the polyp will be assessed during the procedure and the histology will be predicted real time by evaluating the surface mucosal and vascular patterns. The patterns would be classified into one of the four patterns described in our pilot study (tubular and gyrus patterns will be combined to tubulogyrus pattern). Any other patterns detected would be described and kept in the miscellaneous category. If a pattern is not identified on a polyp with either white light or NBI, it will be recorded as such and no attempts will be made to predict histology. Photo documentation of the surface patterns of the polyps will be performed. Polyps will then be removed either with a biopsy forcep or snare and sent for histopathological evaluation. Each polyp removed will have one or more corresponding picture of its surface patterns and these will be labeled accordingly. The total time spent in inspecting the colonic mucosa (excluding the time spent in removal of polyps or clearing the colon of liquid and solid debris) will be measured with a stop watch. Representative images of the various polyp patterns will be reviewed, discussed and standardized amongst all the investigators at both sites. In addition, images of all the polyp patterns will be printed and posted in the endoscopy suites at both hospitals.
The bowel preparation will be evaluated and graded as follow:
Excellent (score=1) - >90% mucosa seen, mostly liquid colonic contents, minimal suctioning needed for adequate visualization.
Good (score=2) - >90% of mucosa seen, mostly liquid colonic contents, significant suctioning needed for adequate visualization Fair (score=3) - > 90% mucosa seen, mixture of liquid and semisolid colonic contents, could be suctioned and/or washed Inadequate (score=4) - <90% mucosa seen, mixture of semisolid ands solid colonic contents, which could not be suctioned or washed
Patients with "Inadequate" (score = 4) bowel prep will be excluded.
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Estágio
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Missouri
-
Kansas City, Missouri, Estados Unidos, 64128
- Kansas City VA Medical Center
-
St. Louis, Missouri, Estados Unidos, 63110
- Barnes Jewish Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion criteria:
- referral for screening or surveillance colonoscopy
- the ability to provide informed consent
Exclusion criteria:
- prior surgical resection of any portion of colon
- prior history of colon cancer
- history of inflammatory bowel disease
- use of anti-platelet agents or anticoagulants that precludes removal of polyps during the procedure
- poor general condition or any other reason to avoid prolonged procedure time
- history of polyposis syndrome or HNPCC
- inability to give informed consent.
- Inadequate bowel preparation
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Diagnóstico
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Número de braços
Armas e Intervenções
Grupo de Participantes / BraçoGrupo de Participantes / Braço |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
Experimental: 1
Standard White Light Colonoscopy
|
Standard White Light Colonoscopy one exam per patient High Definition White Light Colonoscopy one exam per patient |
|
Experimental: 2
High Definition White Light Colonoscopy
|
Standard White Light Colonoscopy one exam per patient High Definition White Light Colonoscopy one exam per patient |
|
Experimental: 3
Narrow Band Imaging Colonoscopy
|
Narrow Band Imaging Colonoscopy one exam per patient |
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
The prevalence of adenomas in the three arms of the study.
Prazo: 2 years
|
Number of subjects with adenomas in the three arms of the study
|
2 years
|
Medidas de resultados secundários
Medidas de resultados secundários
Medida de resultado |
Prazo |
|---|---|
|
Secondary outcome will be number of adenomas detected per subject in the three arms, the sensitivity, specificity, and accuracy of predicting polyp histology real time by the three imaging modalities.
Prazo: 2 years
|
2 years
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Colaboradores
Colaboradores
Investigadores
Investigadores
- Investigador principal: Amit Rastogi, MD, Kansas City VA Medical Center
Publicações e links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- AR0003
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .