Comparação de vários alvos de oxigenação com diferentes interfaces de oxigênio - Impacto nas taxas de fluxo de oxigênio (Interfaces)
Oxygen therapy is at the heart of the healthcare system. Oxygen flow rates depend on a number of confounding factors confounding factors (target used, skin pigmentation, pulse oximeter used, etc.) The investigators have recently have recently demonstrated that the combination of these factors (different peripheral oxygen saturation (SpO2) targets and different oximeters) can have a significant impact on oxygen flows rates. The effect on oxygen flow was not simply additive .
The aim of this study is to evaluate the impact of the interface used on oxygen flow rates in different patient populations (main objective). The investigatoers also evaluate the impact of the interface on carbon dioxide (PaCO2), in particular with closed oxygen masks, with which rebreathing is theoretically possible (secondary objective).
secondary objective).
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Tipo de estudo
Tipo de estudo
Inscrição (Estimado)
Inscrição
Estágio
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
Contato de estudo
- Nome: François Lellouche
- Número de telefone: 1-418-656-8711
- E-mail: françoislellouche@criucpq.ulaval.ca
Locais de estudo
-
-
Quebec
-
Québec, Quebec, Canadá, G1V4G5
- Recrutamento
- Insitut universitaire de cardiologie et de pneumologie de Quebec - Universite Laval
-
Contato:
- Francois Lellouche Principal Investigator
- Número de telefone: 418-656-8711
- E-mail: francois.lellouche@criucpq.ulaval.ca
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Adult (> or = 18 years old)
- Ongoing on conventional oxygen therapy with peripheral oxygen saturation (SpO2) between 88 and 100% with the usual oximeter
- SpO2 < 92% ambient air with the usual oximeter
Exclusion Criteria:
- No SpO2 signal with with the usual oximeter
- False nails or nail polish
- Severe anemia documented on last blood count during current hospitalization (haemoglobin (Hb) < 80g/L)
- Oxygen flow > 6 L/min
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Cuidados de suporte
- Alocação: Randomizado
- Modelo Intervencional: Atribuição cruzada
- Mascaramento: Nenhum (rótulo aberto)
Número de braços
Armas e Intervenções
Grupo de Participantes / BraçoGrupo de Participantes / Braço |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
Outro: Oxímetro Nellcor
|
Oxygen will be administered via nasal cannula up to 6 liters per minute during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the peripheral oxygen saturation (SpO2) target (92% for non chronic obstructive pulmonary disease (non COPD) patient and 90% for chronic obstructive pulmonary disease (COPD) patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. Oxygen will be administered via nasal cannula up to 15 liters per minute during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the SpO2 target (92% for non COPD patient and 90% for COPD patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. Oxygen will be administered via an open during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the SpO2 target (92% for non COPD patient and 90% for COPD patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. Oxygen will be administered via simple oxygen face mask during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the SpO2 target (92% for non COPD patient and 90% for COPD patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. |
|
Outro: Oxímetro Nonin
|
Oxygen will be administered via nasal cannula up to 6 liters per minute during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the peripheral oxygen saturation (SpO2) target (92% for non chronic obstructive pulmonary disease (non COPD) patient and 90% for chronic obstructive pulmonary disease (COPD) patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. |
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Oxygen flow
Prazo: Mean Oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Oxygen flows (or fraction of inspired oxygen (FiO2)) at the end of each study period (last minute average) to reach peripheral oxygen saturation (SpO2) target to reach SpO2 target with specific oxygen administration interfaces |
Mean Oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Medidas de resultados secundários
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Partial oxygen weaning
Prazo: Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Rate of partial oxygen weaning (Oxygen flow <=0.5 L/min) |
Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
|
Complete oxygen weaning
Prazo: Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Rate of complete oxygen weaning (Oxygen flow =0 L/min or FiO2 0.21) |
Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Outras medidas de resultado
Outras medidas de resultado
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Gaps between the different oximeters
Prazo: through period completion, minute 15
|
Average of the SpO2 value gaps between the different oximeters tested |
through period completion, minute 15
|
|
Gaps between PaCO2
Prazo: through period completion, minute 15
|
PaCO2 value at the end of the period |
through period completion, minute 15
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Início do estudo
Conclusão Primária (Estimado)
Conclusão Primária
Conclusão do estudo (Estimado)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- 2025-4198
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .