Elasticidade do Tecido Adiposo Abdominal e dos Membros Inferiores em Pacientes com Lipedema
Elasticidade do Tecido Adiposo Abdominal e dos Membros Inferiores em Pacientes com Lipedema: Um Estudo de Elastografia por Onda de Cisalhamento
Lipedema is a chronic disorder characterized by abnormal bilateral fat deposition in the extremities, predominantly affecting women and typically beginning at puberty. The trunk, hands, and feet are usually spared. Despite its relatively high prevalence, lipedema is frequently underrecognized in clinical practice and is often confused with conditions such as obesity, venous insufficiency, and lymphedema. Patients commonly present with pain, tenderness, and easy bruising.
Current imaging methods have demonstrated increased subcutaneous tissue thickness and fluid infiltration in lipedema; however, no imaging modality has yet been established as a definitive diagnostic tool. Shear wave elastography (SWE) is a noninvasive ultrasound-based technique that enables quantitative assessment of tissue stiffness and may provide additional information regarding tissue structure and mechanical properties.
In this study, we aim to compare lower extremity subcutaneous tissue stiffness in patients with lipedema and healthy controls using SWE. As a secondary objective, we aim to evaluate abdominal subcutaneous tissue stiffness in patients with lipedema and compare these findings with both lower extremity measurements in the same patients and abdominal measurements in individuals without lipedema.
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Descrição detalhada
Lipedema is a disorder characterized by abnormal bilateral fat deposition in the upper and lower extremities, typically beginning at puberty and predominantly affecting women. Its prevalence in the female population is estimated to be approximately 11%. The condition primarily involves the extremities, while the trunk, hands, and dorsum of the feet are typically spared. It has a genetic predisposition and is influenced by hormonal factors. Despite being relatively common, lipedema is frequently overlooked in daily clinical practice. Therefore, accurate clinical recognition of the disease is essential. In the differential diagnosis, it is often confused with obesity, venous insufficiency, and lymphedema. The main symptoms reported by patients with lipedema include pain, tenderness, and easy bruising.
Previous imaging studies using Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) have demonstrated thickening of the subcutaneous tissue without muscle edema, along with fluid infiltration within adipose tissue.
Ultrasonography (US) provides rapid and reliable diagnosis for many musculoskeletal lesions. Due to its ease of use, absence of radiation, and cost-effectiveness, it has become a preferred modality in musculoskeletal imaging. Elastography techniques vary depending on the method of compression, tissue displacement characteristics, and image acquisition techniques. The main types used in clinical practice include strain (compression) elastography, acoustic radiation force, shear wave elastography (SWE), and transient elastography. In addition to providing morphological information, SWE allows quantitative measurement of tissue elasticity and offers valuable insights into mechanical properties related to degeneration, injury, and healing.
This technology represents an ultrasound-based counterpart of manual palpation used by clinicians for tissue characterization. SWE is one of the ultrasound elastography techniques that utilizes shear wave speed (SWS) to assess tissue stiffness. During real-time B-mode ultrasonography, localized transient displacements in the tissue are generated by short-duration acoustic push pulses, producing shear waves. The propagation speed of these waves (SWS) is then recorded.
Measurements can be expressed in meters per second (m/s) or kilopascals (kPa), depending on the system. The square root of tissue elasticity is proportional to SWS, which directly correlates with tissue stiffness. This implies that stiffer tissues allow faster propagation of shear waves. Extracellular matrix components, particularly fibrotic deposits such as collagen, are the primary determinants of tissue stiffness. Ultrasound elastography has been established as an excellent diagnostic modality for conditions such as liver fibrosis, breast cancer, and thyroid cancer. In the field of musculoskeletal medicine, numerous studies have been conducted since the early 1990s, and its clinical application has increased in recent years .
In ultrasonographic studies of lipedema, no significant differences have been observed in the dermis, whereas increased thickness and decreased echogenicity of the subcutaneous tissue have been reported . However, there are currently no studies in the literature investigating lipedema using SWE. An imaging modality that definitively supports the clinical diagnosis of lipedema has not yet been established. The diagnostic performance of existing imaging methods remains limited. Prospective studies are needed to evaluate and compare the diagnostic performance of different imaging techniques. There is also a need for imaging modalities that focus on the pathophysiology of the disease .
In this study, we aimed to compare the stiffness of lower extremity subcutaneous tissue in patients with lipedema, characterized by diffuse subcutaneous tissue expansion, with that of a healthy population using SWE. As a secondary objective, we aimed to evaluate abdominal subcutaneous tissue stiffness using SWE in patients with lipedema and to compare it with both the lower extremity measurements in lipedema patients and the abdominal subcutaneous tissue stiffness in individuals without lipedema.
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Contactos e Locais
Locais de estudo
-
-
Ataşehir
-
Istanbul, Ataşehir, Turquia (Türkiye), 34752
- Fatih Sultan Mehmet Education and Training Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Women aged ≥18 years with lipedema (stages 1-3) and healthy controls were included.
Descrição
Inclusion Criteria:
- Women aged ≥18 years with lipedema (stages 1-3) and healthy controls with adequate cognitive function
Exclusion Criteria:
- Age <18 years Lymphedema Edema of cardiac or nephrogenic origin Diabetes mellitus Thyroid dysfunction Oncological diseases Polyneuropathy or radiculopathy Advanced degenerative diseases affecting the extremities Use of antiepileptic or antidepressant drugs within the last 6 months Use of edema-inducing medications (e.g., corticosteroids, calcium channel blockers, gabapentin, pregabalin) Cognitive impairment preventing participation
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Modelos de observação: OTHER
- Perspectivas de Tempo: CROSS_SECTIONAL
Número de grupos/coortes
Coortes e Intervenções
Grupo / CoorteGrupo / Coorte |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
lipedema group
Women aged ≥18 years with lipedema (stages 1-3) |
Tissue elasticity was assessed using shear wave elastography (SWE) by a radiologist with 18 years of experience, using an RS 85 US device (Samsung Medison, Seoul, Korea) with an SL 10-2 linear probe. Patients were examined in the supine position, and a 10-mm layer of high-viscosity gel was applied to minimize compression. Bilateral measurements were obtained from four sites (anterior thigh, pretibial region, lateral leg, and abdomen), with three measurements per site averaged for analysis. |
|
control group
healty controls |
Tissue elasticity was assessed using shear wave elastography (SWE) by a radiologist with 18 years of experience, using an RS 85 US device (Samsung Medison, Seoul, Korea) with an SL 10-2 linear probe. Patients were examined in the supine position, and a 10-mm layer of high-viscosity gel was applied to minimize compression. Bilateral measurements were obtained from four sites (anterior thigh, pretibial region, lateral leg, and abdomen), with three measurements per site averaged for analysis. |
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Tissue elasticity, as measured by shear-wave elastography (SWE)
Prazo: 1 day
|
Comparison of tissue elasticity at the specified sites in both legs between patients with lipedema and healthy controls |
1 day
|
Medidas de resultados secundários
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Tissue elasticity, as measured by shear-wave elastography (SWE)
Prazo: 1 day
|
The elasticity of subcutaneous adipose tissue in the abdominal region and legs should be measured in patients with lipedema." |
1 day
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Investigador principal: Feyza Akan Begoğlu, Fatih Sultan Mehmet Education and Training Hospital
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- Shearwave study
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .