Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Digital vs. Conventional Indirect Bonding.

8 de julho de 2026 atualizado por: Azienda Ospedaliero-Universitaria Careggi

Comparison of Indirect Bonding of Orthodontic Brackets Using Digital Versus Conventional Technology: A Randomized Controlled Trial on Bonding Time and Bracket Failure

This randomized split-mouth clinical trial will compare digital and conventional indirect bonding techniques for fixed orthodontic bracket placement in adolescent patients requiring treatment in both dental arches.

Each participant will receive both bonding techniques, with allocation of the digital and conventional indirect bonding procedures to the upper or lower arch determined by randomization. The study will evaluate the time required to complete bracket bonding procedures and the early clinical performance of the two techniques, assessed by bracket failure within the first month after appliance placement.

Visão geral do estudo

Status

Recrutamento

Condições

Intervenção / Tratamento

Descrição detalhada

Indirect bonding has been proposed as an alternative to direct bonding for the placement of orthodontic brackets, with potential advantages in terms of clinical efficiency, bracket positioning, and patient comfort. In recent years, computer-aided three-dimensional design and manufacturing methods have enabled the production of digital transfer trays for indirect bonding, offering a potentially more standardized workflow compared with conventional laboratory-based procedures.

This randomized split-mouth clinical trial will compare digital and conventional indirect bonding techniques in patients undergoing fixed orthodontic treatment in both the upper and lower arches. Each participant will receive both techniques, with the allocation of the digital and conventional bonding procedures to the upper or lower arch determined by randomization.

In the digital indirect bonding procedure, transfer trays will be produced using a digital workflow and brackets will be bonded using a pre-coated adhesive system. In the conventional indirect bonding procedure, transfer trays will be produced using a standard laboratory workflow and brackets will be bonded using a conventional orthodontic adhesive system.

The study will assess the procedural efficiency of the two techniques by recording the time required to complete the bracket bonding procedure. Early clinical performance will be evaluated by recording bracket failures during the first month of orthodontic treatment. All procedures and follow-up assessments will be performed in a clinical orthodontic setting.

Tipo de estudo

Intervencional

Inscrição (Estimado)

20

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Locais de estudo

      • Florence, Itália
        • Recrutamento
        • Orthodontic Clinic, Division of Dentistry, Careggi University Hospital
        • Contato:

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Filho
  • Adulto

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  • Patients aged 12 to 18 years requiring fixed orthodontic treatment on both upper and lower arches
  • Presence of full permanent dentition, including erupted second molars

Exclusion Criteria:

  • Presence of dental anomalies in number (supernumerary or missing teeth) in either arch
  • Orthodontic treatment plans involving tooth extractions in either arch
  • Nickel allergy
  • History of cleft lip and/or palate
  • Craniofacial syndromes

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Digital indirect bonding in the upper arch and conventional indirect bonding in the lower arch
Participants assigned to this arm will receive digital indirect bonding in the upper arch and conventional indirect bonding in the lower arch.
Fixed orthodontic appliance will be bonded using a digital indirect bonding technique
Fixed orthodontic appliance will be bonded using a conventional indirect bonding technique
Comparador Ativo: Conventional indirect bonding in the upper arch and digital indirect bonding in the lower arch
Participants assigned to this arm will receive conventional indirect bonding in the upper arch and digital indirect bonding in the lower arch.
Fixed orthodontic appliance will be bonded using a digital indirect bonding technique
Fixed orthodontic appliance will be bonded using a conventional indirect bonding technique

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Time required to complete bracket bonding procedures, measured in minutes
Prazo: During procedure (from the beginning of bracket bonding to completion of bracket placement)
The time required to complete the bracket bonding procedure will be measured in minutes for each participant, from the beginning of the bonding procedure to completion of bracket placement, using the assigned adhesive system.
During procedure (from the beginning of bracket bonding to completion of bracket placement)

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Bracket failure rate within the first month of orthodontic treatment assessed by clinical examination
Prazo: 1 month after placement of the fixed orthodontic appliance
Bracket failure will be assessed by clinical examination and recorded as the number of brackets detached from the tooth surface within the first month after placement of the fixed orthodontic appliance.
1 month after placement of the fixed orthodontic appliance

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

3 de setembro de 2025

Conclusão Primária (Estimado)

20 de julho de 2026

Conclusão do estudo (Estimado)

24 de agosto de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

23 de abril de 2025

Enviado pela primeira vez que atendeu aos critérios de CQ

8 de julho de 2026

Primeira postagem (Real)

9 de julho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

9 de julho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

8 de julho de 2026

Última verificação

1 de julho de 2026

Mais Informações

Termos relacionados a este estudo

Termos MeSH relevantes adicionais

Outros números de identificação do estudo

  • LF17

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

produto fabricado e exportado dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .