Progressing Ankle Brace Restriction on Walking and Running Gait Characteristics in Healthy Individuals
The Effect of Progressing Ankle Brace Restriction on Walking and Running Gait Characteristics in Healthy Individuals
Обзор исследования
Статус
Статус
Условия
Условия
Вмешательство/лечение
Вмешательство/лечение
Подробное описание
Тип исследования
Тип исследования
Регистрация (Действительный)
Регистрация
Фаза
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
Maryland
-
Rockville, Maryland, Соединенные Штаты, 20852
- Sport & Spine Rehab
-
-
Критерии участия
Критерии приемлемости
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- healthy individuals who are able to run for 10 minutes total
Exclusion Criteria:
- pregnancy, lower body injury
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Фундаментальная наука
- Распределение: Н/Д
- Интервенционная модель: Одногрупповое задание
- Маскировка: Нет (открытая этикетка)
Количество рук
Оружие и интервенции
Группа участников / АрмияГруппа участников / Армия |
Вмешательство/лечениеВмешательство/лечение |
|---|---|
|
Экспериментальный: Ankle Brace
Each participant will complete a baseline analysis of 1 minute of walking and 2 minutes of running, repeated 4 more times wearing 4 different braces.
The analysis will be completed on the Walker View Treadmill, which used 3D camera technology to capture lower body kinematics.
The treadmill also has load cells built in to capture gait characteristics
|
Each participant will complete the 1 minute walking and 2 minute running under 5 conditions [1] un-braced, [2] Active Ankle 329 Ankle Sleeve, [3] AS1Pro (a lace-up brace), [4] Eclipse 1 (single-upright brace), and [5] Eclipse 2 (double upright brace)
|
Что измеряет исследование?
Первичные показатели результатов
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Change in Ankle Dorsiflexion/Plantarflexion Range of Motion
Временное ограничение: Ankle Dorsiflexion/Plantarflexion Range of Motion will be measured for the last 30 seconds of the 1 minute walk, and the last 30 seconds of the 2 minute run. It will be measured during each of the 5 conditions.
|
Ankle Dorsiflexion/Plantarflexion Range of Motion will be measured using the Woodway Walker View Treadmill which utilizes a 3D camera
|
Ankle Dorsiflexion/Plantarflexion Range of Motion will be measured for the last 30 seconds of the 1 minute walk, and the last 30 seconds of the 2 minute run. It will be measured during each of the 5 conditions.
|
|
Change in Ankle Inversion/Eversion Range of Motion
Временное ограничение: Ankle Inversion/Eversion Range of Motion will be measured for the last 30 seconds of the 1 minute walk, and the last 30 seconds of the 2 minute run. It will be measured during each of the 5 conditions.
|
Ankle Inversion/Eversion Range of Motion will be measured using the Woodway Walker View Treadmill which utilizes a 3D camera
|
Ankle Inversion/Eversion Range of Motion will be measured for the last 30 seconds of the 1 minute walk, and the last 30 seconds of the 2 minute run. It will be measured during each of the 5 conditions.
|
|
Change in Knee Flexion Range of Motion
Временное ограничение: Knee Flexion Range of Motion will be measured for the last 30 seconds of the 1 minute walk, and the last 30 seconds of the 2 minute run. It will be measured during each of the 5 conditions.
|
Knee Flexion Range of Motion will be measured using the Woodway Walker View Treadmill which utilizes a 3D camera
|
Knee Flexion Range of Motion will be measured for the last 30 seconds of the 1 minute walk, and the last 30 seconds of the 2 minute run. It will be measured during each of the 5 conditions.
|
|
Change in Step Length
Временное ограничение: Step Length will be measured for the last 30 seconds of the 1 minute walk, and the last 30 seconds of the 2 minute run. It will be measured during each of the 5 conditions.
|
Step Length will be measured using the Woodway Walker View Treadmill which utilizes load cells within the treadmill belt
|
Step Length will be measured for the last 30 seconds of the 1 minute walk, and the last 30 seconds of the 2 minute run. It will be measured during each of the 5 conditions.
|
Соавторы и исследователи
Спонсор
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Начало исследования
Первичное завершение (Действительный)
Первичное завершение
Завершение исследования (Действительный)
Завершение исследования
Даты регистрации исследования
Первый отправленный
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Первый опубликованный
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее опубликованное обновление
Последнее отправленное обновление, отвечающее критериям контроля качества
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
Другие идентификационные номера исследования
- AnkleBrace Running
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .