- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT04982588
Китайское клиническое исследование Evolut PRO
Система Medtronic CoreValve™ Evolut™ PRO, китайское клиническое исследование
Interventional study to evaluate the safety and efficacy of the Medtronic CoreValve™ Evolut™ PRO System when used by China implanting centers in Chinese patients with severe symptomatic aortic stenosis (AS) who are at high risk for Surgical Aortic Valve Replacement (SAVR).
Обзор исследования
Статус
Вмешательство/лечение
Подробное описание
The study is targeting 6 centers with a maximum of 8 centers in China and estimating 65 subjects with a maximum of up to 70 subjects with attempted implants including 50 subjects with an attempted implant in primary study population and the first two attempted subjects at each site for roll-in population. The subjects will follow the assessment with pre and post-procedure, discharge, 30 days(primary endpoint), 6 months, 1 year, and annually through 5 years.
Тип исследования
Регистрация (Действительный)
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, Китай, 100000
- Chinese PLA General Hospital, Chinese PLA Medical School
-
Beijing, Beijing Municipality, Китай, 100000
- Beijing Anzhen Hospital, Capital Medical University
-
-
Sichuan
-
Chengdu, Sichuan, Китай, 610000
- West China Hospital of Sichuan University
-
-
Zhejiang
-
Hangzhou, Zhejiang, Китай, 310009
- The Second Affiliated Hospital Zhejiang University School of Medicine
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- Aortic valve area (AVA) < 1.0 cm2 (or indexed AVA <0.6 cm2/m2) OR mean gradient > 40 mmHg, OR max aortic velocity > 4.0 m/sec
- High risk for SAVR defined as STS-PROM score ≥ 8% AND ≤ 15%, OR documented Heart Team agreement of high risk for AVR due to frailty or comorbidities
- Symptoms of aortic stenosis and NYHA ≥ II
Exclusion Criteria:
- Age is less than 65 years old
- Non-calcified aortic valve
- Bicuspid aortic valve with no raphe or 2 raphes (Sievers classification type 0 or type 2)
- Ascending aortic diameter > 4.5 cm
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Н/Д
- Интервенционная модель: Одногрупповое задание
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Экспериментальный: Medtronic CoreValve™ Evolut™ PRO System
The system comprised of the following three components:
|
The system comprised of the following three components:
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
All-cause Mortality
Временное ограничение: 30 days
|
All-cause mortality at 30 days |
30 days
|
|
Percentage (%) of Subjects With Evaluable Echocardiograms With Moderate or Severe Aortic Regurgitation by Transthoracic Echocardiography (TTE)
Временное ограничение: 30 days
|
Percentage (%) of Subjects with evaluable echocardiograms with moderate or severe aortic regurgitation by transthoracic echocardiography (TTE) |
30 days
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Incidence of an VARC II Combined Composite
Временное ограничение: 30 days
|
Incidence of an VARC II combined composite includes the following components:
|
30 days
|
|
Event Rates of the Individual Components of the VARC II Composite
Временное ограничение: 30 days
|
Event rate of the individual components listed in the outcome |
30 days
|
|
New Permanent Pacemaker Rate
Временное ограничение: 30 days
|
New permanent pacemaker rate |
30 days
|
|
Device Success Rate
Временное ограничение: Between 24 hours and 7 days post procedure
|
Device success rate:
|
Between 24 hours and 7 days post procedure
|
|
Valve Performance Parameter - Mean Aortic Gradient
Временное ограничение: 30 days
|
Mean aortic gradient |
30 days
|
|
Valve Performance Parameter - Effective Orifice Area
Временное ограничение: 30 days
|
Effective orifice area |
30 days
|
|
Valve Performance Parameter -Degree of Aortic Regurgitation (Transvalvular, Paravalvular, Total)
Временное ограничение: 30 days
|
Degree of aortic regurgitation (transvalvular, paravalvular, total) |
30 days
|
Другие показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Event Rates of TAVI-related Complications
Временное ограничение: 30 days
|
Rate of the following TAVI-related complications:
|
30 days
|
|
All-cause Mortality
Временное ограничение: 6 months
|
Percentage of participants with all-cause mortality |
6 months
|
|
All-cause Mortality
Временное ограничение: 1 year
|
Percentage of participants with all-cause mortality |
1 year
|
|
All Stroke
Временное ограничение: 6 months
|
Incidence of stroke (disabling and non-disabling) |
6 months
|
|
All Stroke
Временное ограничение: 1 year
|
Incidence of stroke (disabling and non-disabling) |
1 year
|
|
Myocardial Infarction
Временное ограничение: 30 days
|
Incidence of MI |
30 days
|
|
Myocardial Infarction
Временное ограничение: 6 months
|
Incidence of MI |
6 months
|
|
Myocardial Infarction
Временное ограничение: 1 Year
|
Incidence of MI |
1 Year
|
|
Incidence of Life-threatening Bleeding
Временное ограничение: 30 days
|
Incidence of life-threatening bleeding:
|
30 days
|
|
Incidence of Life-threatening Bleeding
Временное ограничение: 6 months
|
Incidence of life-threatening bleeding:
|
6 months
|
|
Incidence of Life-threatening Bleeding
Временное ограничение: 1 Year
|
Incidence of life-threatening bleeding:
|
1 Year
|
|
New AV-Conduction Disturbances (Left Bundle Branch Block (LBBB) and Right Bundle Branch Block (RBBB))
Временное ограничение: 30 days
|
Incidence of either LBBB or RBBB |
30 days
|
|
Incidence of Prosthetic Valve Endocarditis
Временное ограничение: 30 days
|
Incidence of prosthetic valve endocarditis: Any one of the following:
|
30 days
|
|
Incidence of Prosthetic Valve Endocarditis
Временное ограничение: 6 months
|
Incidence of prosthetic valve endocarditis: Any one of the following:
|
6 months
|
|
Incidence of Prosthetic Valve Endocarditis
Временное ограничение: 1 Year
|
Incidence of prosthetic valve endocarditis: Any one of the following:
|
1 Year
|
|
Incidence of Prosthetic Valve Thrombosis
Временное ограничение: 30 days
|
Incidence of Prosthetic valve thrombosis: Any thrombus attached to or near an implanted valve that occludes part of the blood flow path, interferes with valve function, or is sufficiently large to warrant treatment. *Valve-associated thrombus identified at autopsy in a patient whose cause of death was not valve related should not be reported as valve thrombosis. |
30 days
|
|
Incidence of Prosthetic Valve Thrombosis
Временное ограничение: 6 months
|
Incidence of Prosthetic valve thrombosis: Any thrombus attached to or near an implanted valve that occludes part of the blood flow path, interferes with valve function, or is sufficiently large to warrant treatment. *Valve-associated thrombus identified at autopsy in a patient whose cause of death was not valve related should not be reported as valve thrombosis. |
6 months
|
|
Incidence of Prosthetic Valve Thrombosis
Временное ограничение: 1 Year
|
Incidence of Prosthetic valve thrombosis: Any thrombus attached to or near an implanted valve that occludes part of the blood flow path, interferes with valve function, or is sufficiently large to warrant treatment. *Valve-associated thrombus identified at autopsy in a patient whose cause of death was not valve related should not be reported as valve thrombosis. |
1 Year
|
|
Valve-related Dysfunction
Временное ограничение: 1 Year
|
Incidence of valve-related dysfunction defined as moderate or severe prosthetic valve stenosis, or moderate or severe prosthetic regurgitation (per VARC II) |
1 Year
|
|
Incidence of Valve-related Dysfunction Requiring Repeat Procedure
Временное ограничение: 30 days
|
Incidence of Valve-related dysfunction requiring repeat procedure |
30 days
|
|
Incidence of Valve-related Dysfunction Requiring Repeat Procedure
Временное ограничение: 6 months
|
Incidence of Valve-related dysfunction requiring repeat procedure |
6 months
|
|
Incidence of Valve-related Dysfunction Requiring Repeat Procedure
Временное ограничение: 1 Year
|
Incidence of Valve-related dysfunction requiring repeat procedure |
1 Year
|
|
Valve Hemodynamic Performance Metric - Mean Aortic Gradient
Временное ограничение: 1 year
|
Mean aortic gradient |
1 year
|
|
Valve Hemodynamic Performance Metric - Effective Orifice Area
Временное ограничение: 1 year
|
Effective orifice area |
1 year
|
|
Valve Hemodynamic Performance Metric - Degree of Aortic Regurgitation (Transvalvular, Paravalvular, Total)
Временное ограничение: 1 year
|
Degree of aortic regurgitation (transvalvular, paravalvular, total) |
1 year
|
|
New York Heart Association (NYHA) Functional Classification
Временное ограничение: 30 days
|
New York Heart Association (NYHA) functional classification system is a tool that classifies patients with heart failure into one of four classes according to their degree of systems at rest and with activity. Below are the four classes and the associated patient symptoms (i.e., Class I has no limitations of physical activity vs. Class IV is most symptomatic and patient has symptoms of heart failure at rest). Class I: No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation or shortness of breath. Class II: Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, shortness of breath or chest pain. Class III: Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, shortness of breath or chest pain. Class IV: Symptoms of heart failure at rest. Any physical activity causes further discomfort. |
30 days
|
|
New York Heart Association (NYHA) Functional Classification
Временное ограничение: 6 month
|
New York Heart Association (NYHA) functional classification system is a tool that classifies patients with heart failure into one of four classes according to their degree of systems at rest and with activity. Below are the four classes and the associated patient symptoms (i.e., Class I has no limitations of physical activity vs. Class IV is most symptomatic and patient has symptoms of heart failure at rest). Class I: No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation or shortness of breath. Class II: Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, shortness of breath or chest pain. Class III: Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, shortness of breath or chest pain. Class IV: Symptoms of heart failure at rest. Any physical activity causes further discomfort. |
6 month
|
|
New York Heart Association (NYHA) Functional Classification
Временное ограничение: 1 Year
|
New York Heart Association (NYHA) functional classification system is a tool that classifies patients with heart failure into one of four classes according to their degree of systems at rest and with activity. Below are the four classes and the associated patient symptoms (i.e., Class I has no limitations of physical activity vs. Class IV is most symptomatic and patient has symptoms of heart failure at rest). Class I: No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation or shortness of breath. Class II: Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, shortness of breath or chest pain. Class III: Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, shortness of breath or chest pain. Class IV: Symptoms of heart failure at rest. Any physical activity causes further discomfort. |
1 Year
|
|
EQ-5D Quality of Life
Временное ограничение: 30 days
|
EuroQol Group developed this Quality of Life (QOL) questionnaire referred to as EQ-5D that includes a descriptive system comprising five dimensions: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension has 5 levels: no problems, slight problems, moderate problems, severe problems and extreme problems. The patient is asked to indicate his/her health state by ticking the box next to the most appropriate statement in each of the five dimensions. The answers given to ED-5D can be converted into EQ-5D index and utility scores anchored at 0 for death and 1 for perfect health. The EQ-5D Index Score is calculated for each study participant and the descriptive statistical summary of the EQ-5D score for the study population is provided. The EQ-5D Visual Analog Scale (VAS) Score is a scale numbered 0 to 100 (0 is the worse health the patient can imagine and 100 is the best health the patient can imagine). |
30 days
|
|
EQ-5D Quality of Life
Временное ограничение: 1 Year
|
EuroQol Group developed this Quality of Life (QOL) questionnaire referred to as EQ-5D that includes a descriptive system comprising five dimensions: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension has 5 levels: no problems, slight problems, moderate problems, severe problems and extreme problems. The patient is asked to indicate his/her health state by ticking the box next to the most appropriate statement in each of the five dimensions. The answers given to ED-5D can be converted into EQ-5D index and utility scores anchored at 0 for death and 1 for perfect health. The EQ-5D Index Score is calculated for each study participant and the descriptive statistical summary of the EQ-5D score for the study population is provided. The EQ-5D Visual Analog Scale (VAS) Score is a scale numbered 0 to 100 (0 is the worse health the patient can imagine and 100 is the best health the patient can imagine). |
1 Year
|
|
All-cause Mortality
Временное ограничение: 2 year
|
Percentage of participants with all-cause mortality |
2 year
|
|
All Stroke
Временное ограничение: 2 year
|
Incidence of stroke (disabling and non-disabling) |
2 year
|
|
Myocardial Infarction
Временное ограничение: 2 Year
|
Incidence of MI |
2 Year
|
|
Incidence of Life-threatening Bleeding
Временное ограничение: 2 Year
|
Incidence of life-threatening bleeding:
|
2 Year
|
|
Incidence of Prosthetic Valve Endocarditis
Временное ограничение: 2 Year
|
Incidence of prosthetic valve endocarditis: Any one of the following:
|
2 Year
|
|
Incidence of Prosthetic Valve Thrombosis
Временное ограничение: 2 Year
|
Incidence of Prosthetic valve thrombosis: Any thrombus attached to or near an implanted valve that occludes part of the blood flow path, interferes with valve function, or is sufficiently large to warrant treatment. *Valve-associated thrombus identified at autopsy in a patient whose cause of death was not valve related should not be reported as valve thrombosis. |
2 Year
|
|
Valve-related Dysfunction
Временное ограничение: 2 Year
|
Incidence of valve-related dysfunction defined as moderate or severe prosthetic valve stenosis, or moderate or severe prosthetic regurgitation (per VARC II) |
2 Year
|
|
Incidence of Valve-related Dysfunction Requiring Repeat Procedure
Временное ограничение: 2 Year
|
Incidence of Valve-related dysfunction requiring repeat procedure |
2 Year
|
|
Valve Hemodynamic Performance Metric - Mean Aortic Gradient
Временное ограничение: 2 year
|
Mean aortic gradient |
2 year
|
|
Valve Hemodynamic Performance Metric - Effective Orifice Area
Временное ограничение: 2 year
|
Effective orifice area |
2 year
|
|
Valve Hemodynamic Performance Metric - Degree of Aortic Regurgitation (Transvalvular, Paravalvular, Total)
Временное ограничение: 2 year
|
Degree of aortic regurgitation (transvalvular, paravalvular, total) |
2 year
|
|
New York Heart Association (NYHA) Functional Classification
Временное ограничение: 2 Year
|
New York Heart Association (NYHA) functional classification system is a tool that classifies patients with heart failure into one of four classes according to their degree of systems at rest and with activity. Below are the four classes and the associated patient symptoms (i.e., Class I has no limitations of physical activity vs. Class IV is most symptomatic and patient has symptoms of heart failure at rest). Class I: No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation or shortness of breath. Class II: Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, shortness of breath or chest pain. Class III: Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, shortness of breath or chest pain. Class IV: Symptoms of heart failure at rest. Any physical activity causes further discomfort. |
2 Year
|
|
All-cause Mortality
Временное ограничение: 3 year
|
Percentage of participants with all-cause mortality |
3 year
|
|
All Stroke
Временное ограничение: 3 year
|
Incidence of stroke (disabling and non-disabling) |
3 year
|
|
Myocardial Infarction
Временное ограничение: 3 Year
|
Incidence of MI |
3 Year
|
|
Incidence of Life-threatening Bleeding
Временное ограничение: 3 Year
|
Incidence of life-threatening bleeding:
|
3 Year
|
|
Incidence of Prosthetic Valve Endocarditis
Временное ограничение: 3 Year
|
Incidence of prosthetic valve endocarditis: Any one of the following:
|
3 Year
|
|
Incidence of Prosthetic Valve Thrombosis
Временное ограничение: 3 Year
|
Incidence of Prosthetic valve thrombosis: Any thrombus attached to or near an implanted valve that occludes part of the blood flow path, interferes with valve function, or is sufficiently large to warrant treatment. *Valve-associated thrombus identified at autopsy in a patient whose cause of death was not valve related should not be reported as valve thrombosis. |
3 Year
|
|
Valve-related Dysfunction
Временное ограничение: 3 Year
|
Incidence of valve-related dysfunction defined as moderate or severe prosthetic valve stenosis, or moderate or severe prosthetic regurgitation (per VARC II) |
3 Year
|
|
Incidence of Valve-related Dysfunction Requiring Repeat Procedure
Временное ограничение: 3 Year
|
Incidence of Valve-related dysfunction requiring repeat procedure |
3 Year
|
|
Valve Hemodynamic Performance Metric - Mean Aortic Gradient
Временное ограничение: 3 year
|
Mean aortic gradient |
3 year
|
|
Valve Hemodynamic Performance Metric - Effective Orifice Area
Временное ограничение: 3 year
|
Effective orifice area |
3 year
|
|
Valve Hemodynamic Performance Metric - Degree of Aortic Regurgitation (Transvalvular, Paravalvular, Total)
Временное ограничение: 3 year
|
Degree of aortic regurgitation (transvalvular, paravalvular, total) |
3 year
|
|
New York Heart Association (NYHA) Functional Classification
Временное ограничение: 3 Year
|
New York Heart Association (NYHA) functional classification system is a tool that classifies patients with heart failure into one of four classes according to their degree of systems at rest and with activity. Below are the four classes and the associated patient symptoms (i.e., Class I has no limitations of physical activity vs. Class IV is most symptomatic and patient has symptoms of heart failure at rest). Class I: No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation or shortness of breath. Class II: Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, shortness of breath or chest pain. Class III: Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, shortness of breath or chest pain. Class IV: Symptoms of heart failure at rest. Any physical activity causes further discomfort. |
3 Year
|
Соавторы и исследователи
Спонсор
Следователи
- Главный следователь: Jianan Wang, MD, Second Affiliated Hospital, Zhejiang University, School of Medicine
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Действительный)
Завершение исследования (Оцененный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Другие идентификационные номера исследования
- MDT18065EVR009
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .